Skip to product information
1 of 2

Zehnder Caladair Commercial Hexamotion Heat Recovery Ventilation Units

Zehnder Caladair Commercial Hexamotion Heat Recovery Ventilation Units

SKU : KCDF025302

Overview

Designed for temperate climate zones, Season Hexamotion provides air renewal with efficient energy recovery, summer/winter operating of the rotary heat exchanger wheel and adjustable flow rates by potentiometer.
Regular price £7,249.76 GBP Sale price £4,712.34 GBP
Sale Sold out

In Stock

  • For warranty information, please refer to the manufacturer’s warranty policy or contact them directly.
  • Order before 5pm, Dispatched Tomorrow
View full details

Description

Zehnder Caladair Hexamotion Heat Recovery Ventilation Units

Product Part Numbers:

  • Caladair HEXAMOTION 05 D FIRST ECO - CAL49
  • Caladair HEXAMOTION 08 D FIRST ECO - CAL50
  • Caladair HEXAMOTION 15 D FIRST ECO - CAL51
  • Caladair HEXAMOTION 20 D FIRST ECO - CAL52
  • Caladair HEXAMOTION 27 D FIRST ECO - CAL53
  • Caladair HEXAMOTION 35 D FIRST ECO - CAL54
  • Caladair HEXAMOTION 45 D FIRST ECO - CAL55
  • Caladair HEXAMOTION 60 D FIRST ECO - CAL56
  • Caladair HEXAMOTION 80 D FIRST ECO - CAL57

Key Features

  • 🌬️ Airflow rates from 100 to 8000 m³/h
  • 🔥 Heat recovery efficiency up to 80%
  • Self-regulating plug & play system
  • 🏡 Air filtration, temperature control, and climate comfort
  • 🌍 Multilingual communication
  • 🔄 High-performance variable speed rotary heat exchanger
  • 🏢 Ideal for office and industrial applications
  • 🔇 Low noise level for better acoustic comfort
  • ❄️ Cold recovery & night-time cooling

Dimensions

Model Length (mm) Width (mm) Height (mm)
05 1215 675 805
08 1345 805 925
15 1500 805 925
20 1525 885 1005
27 1730 975 1205
35 1730 1140 1205
45 1860 1265 1495
60 2050 1465 1495
80 2260 1545 1645

Regulation Programs

Hexamotion units are available in 5 different regulation programs, available with right or left access depending on airflow direction:

  • SEASON – Optimized for temperate climates, adjustable flow rates, summer/winter heat exchanger operation.
  • FIRST – Self-regulating with active temperature management for efficient energy consumption.
  • PREMIUM CO – FIRST features + changeover water coil for temperatures down to -20°C.
  • PREMIUM DXR – FIRST features + changeover R410A coil for temperatures down to -20°C.
  • PREMIUM BE – FIRST features + electric heater for temperatures down to -20°C.

Controllability

Hexamotion units offer 6 flow rate modulation options for optimized energy consumption:

  • SEASON – Manual fan speed adjustment via potentiometers.
  • ECO – Fan speed adjustment via two airflow settings (LS-HS).
  • Lobby®Constant pressure mode with adjustable fan speed.
  • Diva®CO₂-based airflow modulation with sensor integration.
  • Mac2®Constant airflow modulation (except sizes 05 and 08).
  • Quattro®CO₂-based constant airflow modulation (except sizes 05 and 08).

LCD Controller Functions

  • 🌬️ Airflow control
  • 🌡️ Temperature regulation
  • 🕒 Timer commissioning
  • 🔋 Battery management
  • 🌙 Night over-ventilation
  • 🏠 Local controls
  • ⚠️ Default readings

Filtration System

  • F7 opacimetric filters for fresh and exhaust air
  • Mounted on slides for easy replacement
  • Draught-proof sealing ensures airtight efficiency
  • Optional additional filters for supply air

Construction

  • 10/10e outdoor panels
  • 50mm high-density mineral wool insulation (M0 A1)
  • RAL 7035 painted panels with protective film
  • Galvanized steel internal panels
  • Circular connectors with lip seals for airtight installation
  • Hinged access doors for easy maintenance

Heat Exchanger

  • High-efficiency aluminum rotary heat exchanger 🔄
  • Mounted in a rigid slide rack for easy removal and maintenance
  • Heat recovery efficiency over 80%
  • Variable speed for improved midseason performance

Motors

  • Low-energy EC motors
  • Two motors per unit for optimal performance

Installation Options

  • 🏠 Indoor or outdoor installation
  • Compact design with a small footprint
  • Side duct connections for quick installation
  • No adapters required
  • Integrated rooftop panel for indoor/outdoor use

Ductwork Insulation Recommendations

For best performance, we recommend using Metal Spiral Ducting and Fittings. To ensure airtightness and durability:

  1. Apply duct sealant to male fittings.
  2. Push components together.
  3. Seal the joint with aluminum duct sealing tape.

Ducting in cold areas (e.g. loft spaces) must be insulated with at least 25mm thick material with thermal conductivity ≤ 0.04W/(m·K) to prevent condensation. ✅ Intake and exhaust ducts should be insulated even if there is no loft space. 🚫 Bubble wrap insulation is not compliant with building regulations.

Accessories

Complete your ventilation system with a range of compatible controls, sensors, silencers, and valves/diffusers.

Guarantee

2-Year Parts Guarantee

Important Information

These units are built to order. For lead times and further inquiries, please contact our sales team at 📞 028 2827 5150.

Video