Skip to product information
1 of 1
Final Sale - Not Eligible For Refund

S&P Decor 100 CHZ - Humidity / Timer / Indicator / Shutte - Rated 22l/s

S&P Decor 100 CHZ - Humidity / Timer / Indicator / Shutte - Rated 22l/s

SKU : DECOR-100-CH-Z

Overview

The S&P DECOR-100 CHZ is a compact 100mm axial extract fan designed to remove humid, stale air from bathrooms, toilets and other small domestic spaces. It is suitable for wall or ceiling mounting and can discharge directly outside or through a short length of circular ducting.
£77.03 GBP Excl. VAT: £64.19 GBP

Out of Stock

  • For warranty information, please refer to the manufacturer’s warranty policy or contact them directly.
View full details

Description

Product Part Number

DECOR-100-CH-Z

Product Overview

The S&P DECOR-100 CHZ is a compact 100mm axial extract fan designed to remove humid, stale air from bathrooms, toilets and other small domestic spaces. It is suitable for wall or ceiling mounting and can discharge directly outside or through a short length of circular ducting.

An integrated electronic humidistat automatically activates the fan when the relative humidity rises above the selected level. The humidity setting can be adjusted between 60% and 90% RH, allowing the fan to respond automatically to moisture generated by showering, bathing and other everyday activities.

The adjustable run-on timer allows the fan to continue operating after the humidity has fallen below the selected level or after the connected switch has been turned off. The timer can be adjusted between approximately 2 and 20 minutes, helping remove remaining moisture and odours from the room.

The DECOR-100 CHZ also includes a neon operation indicator and an automatic back-draught shutter, which helps prevent outside air from entering when the fan is switched off. As a “Z” model, it is fitted with a long-life ball-bearing motor for reliable operation.

Technical Specification

Manufacturer: Soler & Palau

Product Range: DECOR

Fan Type: Axial extract fan

Application: Bathrooms, toilets and other small domestic rooms

Installation: Suitable for wall or ceiling mounting

Discharge Arrangement: Direct discharge or connection to an individual or central ducting system

Duct Connection: 100mm diameter

Maximum Airflow: 95m³/h

Maximum Airflow in Litres: Approximately 26.4l/s

Listed Rated Airflow: 22l/s

Fan Speed: 2,500rpm

Maximum Power Consumption: 13W

Supply Voltage: 230V

Frequency: 50Hz

Sound Pressure Level: 40dB(A) at 1.5 metres under free-air conditions

Humidity Sensor: Electronic adjustable humidistat

Humidity Adjustment Range: 60–90% RH

Run-On Timer: Yes

Timer Adjustment Range: Approximately 2–20 minutes

Operation Indicator: Neon indicator light

Back-Draught Shutter: Automatic back-draught shutter

Motor Bearings: Long-life ball bearings

Motor Protection: Thermal overload protection

Electrical Insulation: Class II

IP Rating: IPX4

Maximum Air Temperature: 40°C

Housing Material: Injection-moulded plastic

Colour: White

Front Dimensions: 158mm × 158mm

Overall Depth: 85mm

Body Depth: 68mm

Spigot Diameter: 98mm

Weight: Approximately 0.44kg

Frequently Asked Questions

  • What is an extractor fan used for?

    An extractor fan removes humid, stale or polluted air from a room. They are commonly used in bathrooms, kitchens, utility rooms and other areas where moisture, odours or poor airflow can build up.

  • What extractor fan do I need for a bathroom?

    The right bathroom extractor fan depends on the room size, installation location, duct route and control type required. Timer, humidity and low-carbon options are available depending on the project.

  • Can extractor fans help with condensation?

    Yes, extractor fans can help reduce condensation by removing humid air from wet rooms. However, condensation can also be affected by insulation, heating, airflow and overall ventilation.

  • What is a D-MEV fan?

    A D-MEV fan is a decentralised mechanical extract ventilation fan. It usually runs continuously at a low rate, with boost options when more extraction is needed.

  • What is the difference between an extractor fan and an inline fan?

    A standard extractor fan is usually mounted on a wall, window or ceiling. An inline fan is installed within the duct run, often in a loft or ceiling void, and can be useful where a longer duct route is needed.

BPC Ventilation · Free project support

Not sure which ventilation system you need?

Send us your floor plans for a free ventilation estimate and residential layout guide. Our team will review your project and help you choose suitable MVHR or MEV equipment for your property and budget.

  • Free estimate & layout guide
  • Independent advice across brands
  • Lifetime technical support with every system sold
Send plans for a free estimate

Upload your drawings and project details to get started.

Free residential layout guides cover airflow requirements and unit and valve location guidance. Full ducting route planning is a separate service. Layout guides are not available for commercial projects.

BPC Ventilation · Complete system price promise

Got a quote? We’ll beat it.

Before you buy elsewhere, send us your complete MVHR or MEV system quote. We will beat it on a like-for-like basis, comparing the unit, ducting and required components together.

  • We will beat like-for-like complete system quotes
  • Unit, ducting & system components compared
  • Lifetime technical support with every system sold
Send your quote — we’ll beat it

Upload your complete system quote to get our better offer.

Our price promise applies to complete ventilation system supply quotes, including the unit, ducting and required components. We compare matching specifications and quantities, including VAT and delivery. Unit-only quotes are excluded.