How to Choose the Right Radiators for Your Heat Pump System
How to Choose the Right Radiators for Your Heat Pump System
Choosing the right radiators is an important part of getting good performance from an air source heat pump.
Heat pumps generally operate at lower water temperatures than traditional boilers. This means a radiator that worked well with a boiler may not necessarily provide enough heat when connected to a heat pump system.
The right radiator needs to provide enough heat for the room at the flow temperature the heat pump has been designed to operate at.
If you're planning a heating upgrade, BPC Ventilation supplies air source heat pumps, underfloor heating systems, controls and supporting heating components.
Why Do Heat Pumps Need Correctly Sized Radiators?
Traditional boiler systems commonly operate with relatively high water temperatures, allowing radiators to produce a large amount of heat from a smaller surface area.
Heat pumps are different.
They generally operate more efficiently when supplying water at lower temperatures. As the temperature of the water flowing through a radiator decreases, the amount of heat the radiator can release into the room also reduces.
This means a heat pump system may require:
- Larger radiators
- Higher-output radiator models
- Additional emitters in some rooms
- Alternative emitters such as underfloor heating
The correct option depends on the heat loss and heating requirements of each individual room.
The Energy Saving Trust also highlights the importance of suitably sized radiators or low-temperature underfloor heating when designing a heat pump system.
Start with the Room Heat Loss
Before choosing a radiator, you need to know approximately how much heat the room requires.
A room-by-room heat-loss calculation considers how quickly heat is lost from different areas of the property.
Factors can include:
- Room dimensions
- Wall construction
- Insulation levels
- Window and door sizes
- Glazing performance
- External wall area
- Floor and roof construction
- Outdoor design temperature
- Ventilation and air leakage
- Required indoor temperature
The calculated result is usually expressed in watts and indicates how much heating output the room requires under the chosen design conditions.
Simply selecting a radiator based on the physical dimensions of the room can therefore lead to poor results.
Consider the Heat Pump Flow Temperature
Radiator output depends heavily on the temperatures at which the heating system operates.
Many radiator manufacturers publish headline output figures based on standard test conditions that may be associated with relatively high-temperature heating systems.
A heat pump may operate at considerably lower flow temperatures, meaning the radiator's actual heat output could be significantly lower than the headline figure shown in a product specification.
When comparing radiators, check the manufacturer's output information and correction factors for the temperature difference relevant to the proposed heating system.
For example, a radiator capable of comfortably heating a room when connected to a high-temperature boiler may need to be replaced with a larger or higher-output model when the property changes to a lower-temperature heat pump.
What Does Delta T Mean for Radiator Sizing?
When looking at radiator specifications, you may see outputs quoted using a value such as ΔT50 or another Delta T figure.
Delta T represents the difference between the average water temperature inside the radiator and the required room temperature.
If a radiator's advertised output is based on a higher Delta T than your heat pump system will actually use, the radiator will provide less heat under real operating conditions.
This is why the manufacturer's correction data should be used when selecting radiators for lower-temperature systems.
The radiator needs to provide the required room output at the actual design temperatures of the heat pump system, not simply at the manufacturer's headline test condition.
Bigger Radiators Can Help a Heat Pump Run at Lower Temperatures
Increasing the available radiator surface area allows more heat to be transferred into the room at a lower water temperature.
This is why larger or higher-output radiators can be beneficial when installing an air source heat pump.
Correct emitter sizing may allow the heating system to achieve the required room temperatures while using lower flow temperatures.
Lower required flow temperatures can help improve heat pump efficiency, provided the wider system is correctly designed.
Do You Need to Replace Every Radiator?
Not necessarily.
Some existing radiators may already be large enough to provide the required heat output at the proposed heat pump flow temperature.
Others may need to be upgraded.
Upgrades may be more likely in rooms with:
- Higher heat loss
- Large external wall areas
- Large windows or glazed doors
- Higher required indoor temperatures
- Small existing radiators
A room-by-room assessment is therefore much more useful than assuming every radiator in the property automatically needs to be replaced.
Single, Double and Triple Panel Radiators
Radiators are available in different panel and convector configurations.
Increasing the number of panels and convector fins can increase the available heat output without necessarily requiring a much wider radiator.
This can be useful where wall space is limited.
For example, a higher-output double or triple panel radiator may provide the required heat output in a location where fitting a significantly wider radiator would be impractical.
However, the correct radiator should always be selected based on its calculated output at the heating system's intended operating temperatures rather than simply choosing a radiator based on the number of panels.
Should You Choose the Biggest Radiator Possible?
Not necessarily.
The objective is to select a radiator that can comfortably meet the calculated room heat loss at the chosen system temperatures.
An unnecessarily oversized radiator can:
- Take up more wall space
- Cost more than required
- Make room layouts more difficult
- Be unnecessary if the required heat output can be achieved with a smaller emitter
Radiator sizing should therefore be based on the heating calculation rather than simply fitting the largest unit available.
Radiator Size Isn't the Only Consideration
When choosing radiators for a heat pump system, also consider:
- Available wall space
- Furniture positioning
- Pipework routes
- Radiator depth
- Window positions
- Required room temperature
- Radiator valves and controls
- Accessibility
- Overall appearance
Radiator locations should ideally be considered early enough in the project to make sure suitable wall space and pipework routes are available.
What About Underfloor Heating?
Radiators are not the only heating-emitter option for an air source heat pump.
Water underfloor heating is particularly well suited to lower-temperature heating because it uses a large floor area to distribute warmth throughout the room.
This large heating surface can allow the required room output to be achieved using relatively low water temperatures when the system is properly designed.
Some properties use a combination of underfloor heating and radiators.
For example:
- Underfloor heating downstairs
- Radiators upstairs
A mixed system can work effectively when both the underfloor heating and radiators have been designed around the requirements of the same heat pump system.
Underfloor Heating Downstairs and Radiators Upstairs
Using underfloor heating on the ground floor and radiators upstairs is a common option for new builds and renovation projects.
The ground floor may provide suitable space for UFH pipework during construction, while upstairs bedrooms can continue to use wall-mounted radiators.
However, both emitter types still need to be considered as part of the complete system.
The design should account for:
- Required room heat outputs
- Proposed flow temperatures
- UFH circuit design
- Radiator outputs
- Heating zones
- Water flow requirements
- Heat pump controls
How Does an Air Source Heat Pump Work with Radiators?
An air source heat pump extracts thermal energy from the outside air and transfers that energy into the property's water-based heating system.
The heated water can then circulate through suitable emitters including radiators or underfloor heating.
The key difference compared with many traditional boiler systems is that a heat pump generally benefits from operating at lower water temperatures.
The radiators therefore need to be capable of producing enough heat at those lower temperatures.
Avoid Choosing Radiators Using Boiler Sizing Alone
One of the main mistakes when changing from a boiler to a heat pump is assuming the existing radiator specification will automatically remain suitable.
The existing radiators may have originally been selected around much higher water temperatures.
A heat pump system should instead consider:
- The room heat loss
- The proposed system flow temperature
- The radiator output at that temperature
- The overall heat pump performance
If the radiator cannot provide the required heat output at the chosen operating temperatures, it may need to be increased in size or replaced with a higher-output alternative.
What About Thermostatic Radiator Valves?
Thermostatic radiator valves, commonly known as TRVs, can provide room-level temperature control by adjusting the flow of heating water through individual radiators.
However, controls should be considered as part of the overall heat pump design.
Heat pumps generally require suitable system water flow and should not be configured in a way that causes excessive short cycling or leaves too little of the heating system available to accept heat.
The appropriate control strategy will depend on the system design, heat pump manufacturer and zoning arrangement.
Heat Pump Sizing and Radiator Sizing Go Together
The heat pump itself should also be sized around the property's calculated heating demand.
Choosing the outdoor unit and heating emitters separately can lead to mismatched equipment.
A complete assessment should consider:
- Whole-property heat loss
- Room-by-room heat loss
- Required heat pump output
- Heat pump performance at winter design temperatures
- Heating flow temperature
- Radiator output
- Underfloor heating output where applicable
- Domestic hot water requirements
- Heating controls
Improving Insulation Can Reduce Radiator Requirements
The heat required by a room depends on how quickly heat escapes from the property.
Improving insulation, glazing or airtightness can reduce heat loss, potentially reducing the amount of heating output needed to maintain the required indoor temperature.
This is why heat-loss calculations should ideally reflect the property's intended construction or improvement level.
If insulation improvements are being completed as part of a renovation, those changes should be considered before final radiator and heat pump sizes are selected.
Planning Radiators Early
If you're building a new home or completing a major renovation, radiator positions should ideally be planned during the design stage.
This allows you to consider:
- Available wall space
- Kitchen layouts
- Furniture
- Window positions
- Pipework routes
- Radiator dimensions
- Room heat requirements
Planning early can prevent a situation where the required radiator output cannot be achieved because the only available wall space is too limited.
Heating System Support from BPC Ventilation
If you're planning an air source heat pump system, BPC Ventilation's heating team can provide support when selecting suitable heating equipment and system components for your project.
BPC currently supplies:
- Air source heat pumps
- Underfloor heating systems
- Hot water cylinders
- Buffer tanks
- Thermostats and heating controls
- Supporting heating components
Where radiators are being used with a heat pump, their required output should be confirmed against the room heat loss and proposed heating temperatures before final equipment selection.
Explore BPC Ventilation's heating solutions and system support
Choosing the Right Heat Pump Radiators
The best radiator for a heat pump system is not simply the biggest radiator that will fit on the wall.
The radiator needs to provide the required room heating output at the temperatures the heat pump has been designed to operate at.
Start with an accurate room heat-loss calculation, consider the proposed flow temperature and check the manufacturer's radiator performance data before selecting each emitter.
If some rooms require more output than the existing radiators can provide, larger radiators, higher-output models or underfloor heating may need to be considered.