Hi-Flow Silencer 204x60x0.5m

Hi-Flow Silencer 204x60x0.5m

SKU : RASH204500

Overview

The Verplas 204 x 60mm Hi-Flow Duct Silencer is designed to reduce noise transmission through ventilation ductwork while maintaining efficient airflow and minimal resistance. Manufactured from durable white UPVC and lined with acoustic material, this 1-metre silencer helps reduce fan noise and sound transfer between rooms, creating a quieter and more comfortable indoor environment. Designed for use with Verplas System 204 rectangular ducting, the silencer features a high-flow design with a minimum free area of 11,664mm². Its low-profile construction makes it suitable for installation in ceiling voids and other areas where space is limited.
£54.68 GBP Excl. VAT: £45.57 GBP

In Stock

  • For warranty information, please refer to the manufacturer’s warranty policy or contact them directly.
View full details

Description

Product Part Number

RASH204500

Product Overview

The Verplas 204 x 60mm Hi-Flow Duct Silencer is designed to reduce noise transmission through ventilation ductwork while maintaining efficient airflow and minimal resistance.

Manufactured from durable white UPVC and lined with acoustic material, this 1-metre silencer helps reduce fan noise and sound transfer between rooms, creating a quieter and more comfortable indoor environment.

Designed for use with Verplas System 204 rectangular ducting, the silencer features a high-flow design with a minimum free area of 11,664mm². Its low-profile construction makes it suitable for installation in ceiling voids and other areas where space is limited.

Suitable for domestic extract ventilation and Mechanical Ventilation with Heat Recovery (MVHR) systems, the VKC5664 provides an effective solution for reducing duct-borne noise without significantly restricting airflow.

Key Features

  • Effective Noise Reduction: Acoustic lining helps reduce fan noise and sound transmission between rooms.
  • High-Flow Design: Maintains efficient ventilation performance with low airflow resistance.
  • Durable Construction: Manufactured from lightweight, corrosion-resistant UPVC.
  • Space-Saving Design: Rectangular profile suitable for installations with limited space.
  • Easy Installation: Female adaptor connections designed for Verplas System 204 ducting.
  • Versatile Application: Suitable for domestic extract ventilation and MVHR systems.

Technical Specification

Specification Details
Manufacturer Verplas
Product Code VKC5664
Product Type Hi-Flow Duct Silencer / Attenuator
Duct Size 204 x 60mm
Nominal Length 1,000mm
Overall Length 1,122mm
Maximum Body Width 209mm
Maximum Body Height 95mm
Material UPVC with acoustic lining
Colour White
Minimum Free Area 11,664mm²
Weight 1.405kg
Operating Temperature -15°C to +60°C
Compatibility Verplas System 204
Connection Female adaptor
Box Quantity 5
Ductwork Specification DW/154
Flammability Standard UL94HB

Airflow Performance

Airflow Rate Pressure Drop
8 l/s 1.00 Pa
13 l/s 1.60 Pa
21 l/s 4.20 Pa
30 l/s 8.00 Pa
60 l/s 27.80 Pa
120 l/s 104.00 Pa

Frequently Asked Questions

  • What is thermal ductwork used for?

    Thermal ductwork is used in ventilation systems where an insulated duct run is required. It can help reduce heat loss and lower the risk of condensation in suitable duct routes.

  • Where is thermal ductwork commonly installed?

    Thermal ductwork is commonly used in areas where ducting may pass through colder spaces, such as lofts, roof spaces, ceiling voids or unheated areas, depending on the ventilation design.

  • Does insulated ducting prevent condensation inside the duct?

    Correctly specified insulation can significantly reduce the risk of condensation by limiting temperature differences between the duct surface and surrounding air.

  • Is thermal ducting a building regulation requirement?

    Insulation requirements depend on the duct location, system and applicable Building Regulations. Ductwork passing through unheated spaces commonly requires suitable insulation.

  • Do I still need thermal ducting if the loft itself is well insulated?

    Potentially, yes. If the ductwork is outside the insulated building envelope or carries air at a significantly different temperature, additional duct insulation may still be required.

BPC Ventilation · Free project support

Not sure which ventilation system you need?

Send us your floor plans for a free ventilation estimate and residential layout guide. Our team will review your project and help you choose suitable MVHR or MEV equipment for your property and budget.

  • Free estimate & layout guide
  • Independent advice across brands
  • Lifetime technical support with every system sold
Send plans for a free estimate

Upload your drawings and project details to get started.

Free residential layout guides cover airflow requirements and unit and valve location guidance. Full ducting route planning is a separate service. Layout guides are not available for commercial projects.

BPC Ventilation · Complete system price promise

Got a quote? We’ll beat it.

Before you buy elsewhere, send us your complete MVHR or MEV system quote. We will beat it on a like-for-like basis, comparing the unit, ducting and required components together.

  • We will beat like-for-like complete system quotes
  • Unit, ducting & system components compared
  • Lifetime technical support with every system sold
Send your quote — we’ll beat it

Upload your complete system quote to get our better offer.

Our price promise applies to complete ventilation system supply quotes, including the unit, ducting and required components. We compare matching specifications and quantities, including VAT and delivery. Unit-only quotes are excluded.