The Sentinel Econiq are Latest flagship and highest specification MVHR units from Vent Axia
Vent Axia are the largest manufacture of heat recovery units in the UK and the Econiq S is suitable for houses with a max floor area of 210m2
With a combination of being easy to install with high-quality construction, SAP Appendix Q approval and has multiple control and commissioning options including smartphone control make this unit top of the list for all types of homes
BPC Ventilation are the largest independent MVHR specialists and supply this unit with a 5-year parts warranty* and lifetime technical support on our top-quality systems.
Key Features
- Suitable for floor areas up to 210m2
- Delivers an airflow rate of up to 350 m³/hour @ 150 Pa
- High heat recovery efficiency of up to 93%.
- Low weight of only 32KG
- Digital controller on unit with optional wall mounting kit
- Easy Smartphone App Commissioning
- Sentinel-X wireless controls platform
- Full 100% automatic summer bypass to supply unheated air in the summer
- Sap Appendix Q (BRE) approved
- Approved Document F aligned commissioning wizard
- Internal humidity sensor for automatic speed control
- Ultra Quiet
- Unit mounted control panel
- Airtight Housing
- Latest highly efficient soft start EC3 Motors
- Up to 93% heat recovery
- Horizontal or vertical duct connections
- Sound levels as low as 15.5 dB(A)
- Left and Right configuration via control panel
- Manufactured in the UK
- PVC Counterflow heat recovery core
- 2 x G3 filters and Optional ePM10 (M5) and ePM2.5 (F7) filtration
- Multiple Control options including 0 to100% fan speed settings, Humidity, BMS, timer delay, 0-10v & 240v boost options
- Filter check
- RF858 connectivity, 802.11b/g/n Wi-Fi and Bluetooth low energy 4.2
- Optional Wall mounting kit for controller
- Optional Acoustic enclosure and Top Box (S only)
- Optional HMI Kit
- Optional 0-10v, Co2, Temp, Humidity wired room sensors
- Optional wireless Temp, Humidity and 4 speed switches
- Optional 240v Co2, Temp, Humidity, PIR and 4 speed switches
- Optional AIM Alarm Interface
- Optional Volt free expansion board
- Optional 0-10v expansion board
- Optional Purge van integration
- UK manufactured MVHR unit with 5 Year parts warranty through BPC
High Performance
The Sentinel Econiq S benefits from the latest high efficiency, ED/DC backward curved impeller design, ensuring the lowest possible energy consumption, ultra quiet operation and an exceptional performance range to houses with a floor area of up to 220m2
With a high performance of 350 m3/hr at 150Pa while still achieving almost 93% heat recovery. The fully automatic capability of the Econiq range means that adequate ventilation is always achieved.
Integral Humidity Sensor
The integral humidity sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room. The nighttime relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature.
Digital Controller
A digital controller is supplied fitted to the unit allowing multiple options on programming and controllability, including 4 x Integral infinitely variable fan speed control on supply and extract there is also an optional kit allowing you to remove the controller from the unit and wall mount in your chosen location
There is also a pin number facility to prevent accidental resetting of commissioning settings
App Control
The Vent-Axia Connect smartphone application allows full control with a multitude of functions from automated to fully adjustable from the comfort of the sofa on iOS and Android smartphones
Orientation
This unit can be electronically changed from right to left hand orientation
Spigot Options
The 200mm Spigots may be re-positioned from a vertical to a horizontal connection or a combination of vertical and horizontal connection.
100% summer By-pass
During hot weather you can activate the summer By-Pass that will only bring the filtered air in at external temperatures allowing you to naturally cool your home
Low Noise Levels
The Lo-Carbon Sentinel Econiq is one of the quietest systems on the market, with a noise level as low as 15.5 dB(A). This is facilitated using an internal acoustic enclosure
Demand Control Ventilation
The Vent-Axia Connect smartphone application allows a multitude of functions to be adjusted from the comfort of the sofa, available on iOS and Android.
BMS
The BMS capability is also ideal for those commercial applications where landlords or property managers want to monitor and optimise building performance and maintenance.
The Kinetic BMS can provide status information and its self-diagnostics can report if any fault is found.
Filtration
The unit comes supplied with ISO 60% Coarse (G4) which can filter out sand, fine hair, and particles larger than 10μm.
Additional filtration can be achieved with a selection of optional supply air filters (extract still use G4)
- ePM10 (M5), which can filter pollen, stone dust, and particles smaller or equal to 10μm
- 5 (F7), which can filter out mould spores, bacteria and particles smaller or equal to 2.5μm.
Acoustic enclosure
For scenarios where noise is a critical issue, an optional Acoustic Enclosure is available to reduce breakout noise and the Acoustic Top Box will reduce in-duct noise at key frequencies.
Frost Protection
Automatic frost protection effective to -20°C
Fresh air programme
Evening Fresh’ turns the unit to maximum speed with the bypass
operational for 2 hours or until the user comfort temperature is
reached (default 21°C).
Night-time Fresh’ will run the unit at maximum speed with the
bypass operational throughout the night or until the dwelling
reaches minimum temperature (default 14°C).
External Control Components
- Integral BMS input/output interfaces –
- 0-10V proportional speed adjustment
- Volt free contacts
- 24V sensor supply
- Integral on/off or trickle boost function from remote switch, e.g. PIR occupancy detector
- Switched Live input with adjustable ‘delay-on’ feature
- Fan failure or component failure indicated via individual fault code display
- Running time counter
Model
- Sentinel Econiq S 499883
- Sentinel Econiq S with Acoustic Top Box & Enclosure 479550A
- Sentinel Econiq S with Acoustic Top Box 479549A
- Sentinel Econiq S with Acoustic Enclosure 479548A
Accessories
- Volt-free Expansion (Four additional inputs) 472697
- Switched Live Expansion (Two additional inputs) 472699
- 0V - 10V Input Board (Two inputs) 472701
- Acoustic Purge Fan 477988
- Acoustic Purge Fan XL 479829
- Wall Mounting Kit for Controller 411628
- ISO 60% Coarse (G4) Filter 2 per Pack 411689
- ISO ePM10 50% (M5) Filter 1 per Pack 472669
- ISO ePM2.5 70% (F7) Filter 1 per Pack 472671
Optional wall Sensor Overview