{"title":"Commercial MVHR Units","description":"\u003cp\u003eBrowse our range of commercial MVHR units designed for offices, schools, classrooms, commercial buildings and larger ventilation projects. Commercial MVHR units provide mechanical ventilation with heat recovery, helping to extract stale air while supplying fresh filtered air back into the building.\u003c\/p\u003e\n\u003cp\u003eAt BPC Ventilation, we supply commercial heat recovery units from trusted manufacturers including Mitsubishi, BSK and Zehnder Caladair. Our team can provide technical advice and design support to help you choose a suitable unit based on airflow requirements, building layout, installation location and project type.\u003cbr\u003e\u003c\/p\u003e","products":[{"product_id":"caladair-freetime","title":"Zehnder Caladair Freetime 500 First Eco Commercial MVHR Unit","description":"\u003ch3\u003e\u003cstrong\u003eZehnder Caladair Freetime Smart First Commercial MVHR Units\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eCaladair FREETIME 500 First Eco\u003c\/strong\u003e - CAL19\u003cbr\u003e\u003cstrong\u003ePlease Note\u003c\/strong\u003e – These units are built to order. For lead time details on these Caladair Freetime Commercial Units, please contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTop-quality \u003cstrong\u003ecommercial heat recovery unit\u003c\/strong\u003e, vertically mounted. Each unit is \u003cstrong\u003eindividually manufactured\u003c\/strong\u003e to suit multiple applications and specifications. The \u003cstrong\u003eFreetime range\u003c\/strong\u003e is a self-regulating dual-flow handling unit with \u003cstrong\u003eMODBUS communication\u003c\/strong\u003e, dedicated to tertiary sector and industrial applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDimensions \u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e900\u003c\/td\u003e\n\u003ctd\u003e570\u003c\/td\u003e\n\u003ctd\u003e970\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003e1080\u003c\/td\u003e\n\u003ctd\u003e700\u003c\/td\u003e\n\u003ctd\u003e1090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1500\u003c\/td\u003e\n\u003ctd\u003e1400\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003ctd\u003e1140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003ctd\u003e1500\u003c\/td\u003e\n\u003ctd\u003e830\u003c\/td\u003e\n\u003ctd\u003e1220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003ctd\u003e1610\u003c\/td\u003e\n\u003ctd\u003e920\u003c\/td\u003e\n\u003ctd\u003e1420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3500\u003c\/td\u003e\n\u003ctd\u003e1730\u003c\/td\u003e\n\u003ctd\u003e1085\u003c\/td\u003e\n\u003ctd\u003e1420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eModels Available \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEASON\u003c\/strong\u003e: For temperate climate zones, ideal for air circulation in buildings with energy recovery. Includes bypass summer\/winter mode, adjustable flow rate via potentiometer. No self-regulation, no coil or battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFIRST\u003c\/strong\u003e: Self-regulating unit for temperate climates with temperature management for optimal energy consumption and comfort. No integrated coil or battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePREMIUM BE\u003c\/strong\u003e: Same as \u003cstrong\u003eFIRST\u003c\/strong\u003e, but with an \u003cstrong\u003eelectric heater\u003c\/strong\u003e for temperatures as low as \u003cstrong\u003e-20°C\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePREMIUM BC\u003c\/strong\u003e: Same as \u003cstrong\u003eFIRST\u003c\/strong\u003e, but with a \u003cstrong\u003ehot water heater\u003c\/strong\u003e for exterior temperatures as low as \u003cstrong\u003e-20°C\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControllability \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThere are four available control options:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLobby\u003c\/strong\u003e: LCD controller for constant pressure fan control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiva\u003c\/strong\u003e: Integral CO₂ sensor with airflow management via LCD controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMac2\u003c\/strong\u003e: Constant airflow between 2 adjustable airflows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuattro\u003c\/strong\u003e: Integral CO₂ sensor for airflow modulation between 2 adjustable constant airflows.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eLCD Controller Functions:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWeekly timer\u003c\/li\u003e\n\u003cli\u003eHoliday timer\u003c\/li\u003e\n\u003cli\u003eSummer bypass - night-time cooling\u003c\/li\u003e\n\u003cli\u003eFault finding\u003c\/li\u003e\n\u003cli\u003eSpeed parameters\u003c\/li\u003e\n\u003cli\u003eFilter indicator\u003c\/li\u003e\n\u003cli\u003eFire alarm integration\u003c\/li\u003e\n\u003cli\u003eTemperature sensors\u003c\/li\u003e\n\u003cli\u003eIntegration via \u003cstrong\u003eModbus\u003c\/strong\u003e, \u003cstrong\u003eBacnet\u003c\/strong\u003e, or \u003cstrong\u003eWeb\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFiltration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x F7\u003c\/strong\u003e filter on the supply air and a \u003cstrong\u003eG4\u003c\/strong\u003e filter on the extracted air.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Construction\u003c\/strong\u003e: Airtight \u003cstrong\u003e10-gauge galvanized steel double-skin panels\u003c\/strong\u003e with \u003cstrong\u003e25mm high-density mineral wool insulation\u003c\/strong\u003e in accordance with EN1886.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Face\u003c\/strong\u003e: Pre-lacquered with a protective film in \u003cstrong\u003eRAL 7035\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections\u003c\/strong\u003e: Circular branch connections with rubber seals. Airtight construction to \u003cstrong\u003eATEC CSTB n° 13-224-12\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHeat Exchanger \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly efficient\u003c\/strong\u003e aluminium rotary heat exchanger providing up to \u003cstrong\u003e80% heat recovery\u003c\/strong\u003e. Built for long-lasting performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMotors \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-efficiency\u003c\/strong\u003e direct-drive \u003cstrong\u003eDC motors\u003c\/strong\u003e with electronic commutation (EC), thermal protection, and built-in variable speed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEconological® EC technology\u003c\/strong\u003e ensures low energy consumption (RT2012).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow noise levels\u003c\/strong\u003e for improved acoustic comfort.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVertical Mounting\u003c\/strong\u003e: The unit is mounted on the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate Drain\u003c\/strong\u003e: 15mm BSP metal pipe provided for connection to a drain via a waterless trap.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInsulation of Ductwork \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Ducting\u003c\/strong\u003e: Use \u003cstrong\u003eMetal Spiral ducting\u003c\/strong\u003e and fittings for superior strength.\u003c\/li\u003e\n\u003cli\u003eFor optimal airtightness and durability, use \u003cstrong\u003eself-sealing fittings\u003c\/strong\u003e or a combination of \u003cstrong\u003eDucting Sealant\u003c\/strong\u003e and \u003cstrong\u003eAluminium Duct Sealing Tape\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Area Ducting\u003c\/strong\u003e: Ensure \u003cstrong\u003e25mm thick insulation\u003c\/strong\u003e with a thermal conductivity of \u003cstrong\u003e0.04W\/(m.k)\u003c\/strong\u003e or less.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTip\u003c\/strong\u003e: If ducting is in a loft space, insulate to prevent condensation from forming.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eA full range of \u003cstrong\u003ecompatible ducting systems\u003c\/strong\u003e, \u003cstrong\u003econtrols\u003c\/strong\u003e, \u003cstrong\u003esensors\u003c\/strong\u003e, \u003cstrong\u003ein-line silencers\u003c\/strong\u003e, and \u003cstrong\u003efloor\/wall\/ceiling inlet and outlet diffusers\u003c\/strong\u003e available to complete your installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGuarantee \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e for peace of mind.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003eZehnder Caladair Freetime Smart First\u003c\/strong\u003e Commercial MVHR Units offer exceptional performance, energy efficiency, and reliability for \u003cstrong\u003etertiary sector\u003c\/strong\u003e and \u003cstrong\u003eindustrial applications\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736193261894,"sku":"KCDF024143","price":5128.94,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/freetime.png?v=1732550848"},{"product_id":"caladair-hexmotion","title":"Zehnder Caladair Commercial Hexamotion Heat Recovery Ventilation Units","description":"\u003cp\u003e\u003cstrong\u003eZehnder Caladair Hexamotion Heat Recovery Ventilation Units\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Part Numbers:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCaladair HEXAMOTION 05 D FIRST ECO - CAL49\u003c\/li\u003e\n\u003cli\u003eCaladair HEXAMOTION 08 D FIRST ECO - CAL50\u003c\/li\u003e\n\u003cli\u003eCaladair HEXAMOTION 15 D FIRST ECO - CAL51\u003c\/li\u003e\n\u003cli\u003eCaladair HEXAMOTION 20 D FIRST ECO - CAL52\u003c\/li\u003e\n\u003cli\u003eCaladair HEXAMOTION 27 D FIRST ECO - CAL53\u003c\/li\u003e\n\u003cli\u003eCaladair HEXAMOTION 35 D FIRST ECO - CAL54\u003c\/li\u003e\n\u003cli\u003eCaladair HEXAMOTION 45 D FIRST ECO - CAL55\u003c\/li\u003e\n\u003cli\u003eCaladair HEXAMOTION 60 D FIRST ECO - CAL56\u003c\/li\u003e\n\u003cli\u003eCaladair HEXAMOTION 80 D FIRST ECO - CAL57\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003eAirflow rates\u003c\/strong\u003e from 100 to 8000 m³\/h\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eHeat recovery efficiency\u003c\/strong\u003e up to 80%\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eSelf-regulating\u003c\/strong\u003e plug \u0026amp; play system\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eAir filtration, temperature control, and climate comfort\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eMultilingual communication\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eHigh-performance variable speed rotary heat exchanger\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eIdeal for office and industrial applications\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eLow noise level\u003c\/strong\u003e for better acoustic comfort\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eCold recovery \u0026amp; night-time cooling\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e1215\u003c\/td\u003e\n\u003ctd\u003e675\u003c\/td\u003e\n\u003ctd\u003e805\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003e1345\u003c\/td\u003e\n\u003ctd\u003e805\u003c\/td\u003e\n\u003ctd\u003e925\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e1500\u003c\/td\u003e\n\u003ctd\u003e805\u003c\/td\u003e\n\u003ctd\u003e925\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e1525\u003c\/td\u003e\n\u003ctd\u003e885\u003c\/td\u003e\n\u003ctd\u003e1005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003ctd\u003e1730\u003c\/td\u003e\n\u003ctd\u003e975\u003c\/td\u003e\n\u003ctd\u003e1205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e1730\u003c\/td\u003e\n\u003ctd\u003e1140\u003c\/td\u003e\n\u003ctd\u003e1205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e1860\u003c\/td\u003e\n\u003ctd\u003e1265\u003c\/td\u003e\n\u003ctd\u003e1495\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e2050\u003c\/td\u003e\n\u003ctd\u003e1465\u003c\/td\u003e\n\u003ctd\u003e1495\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003ctd\u003e2260\u003c\/td\u003e\n\u003ctd\u003e1545\u003c\/td\u003e\n\u003ctd\u003e1645\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRegulation Programs\u003c\/h3\u003e\n\u003cp\u003eHexamotion units are available in \u003cstrong\u003e5 different regulation programs\u003c\/strong\u003e, available with right or left access depending on airflow direction:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEASON\u003c\/strong\u003e – Optimized for temperate climates, adjustable flow rates, summer\/winter heat exchanger operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFIRST\u003c\/strong\u003e – Self-regulating with \u003cstrong\u003eactive temperature management\u003c\/strong\u003e for efficient energy consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePREMIUM CO\u003c\/strong\u003e – FIRST features + \u003cstrong\u003echangeover water coil\u003c\/strong\u003e for temperatures down to -20°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePREMIUM DXR\u003c\/strong\u003e – FIRST features + \u003cstrong\u003echangeover R410A coil\u003c\/strong\u003e for temperatures down to -20°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePREMIUM BE\u003c\/strong\u003e – FIRST features + \u003cstrong\u003eelectric heater\u003c\/strong\u003e for temperatures down to -20°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eControllability\u003c\/h3\u003e\n\u003cp\u003eHexamotion units offer \u003cstrong\u003e6 flow rate modulation options\u003c\/strong\u003e for optimized energy consumption:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEASON\u003c\/strong\u003e – Manual fan speed adjustment via \u003cstrong\u003epotentiometers\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECO\u003c\/strong\u003e – Fan speed adjustment via \u003cstrong\u003etwo airflow settings (LS-HS)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLobby®\u003c\/strong\u003e – \u003cstrong\u003eConstant pressure mode\u003c\/strong\u003e with adjustable fan speed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiva®\u003c\/strong\u003e – \u003cstrong\u003eCO₂-based airflow modulation\u003c\/strong\u003e with sensor integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMac2®\u003c\/strong\u003e – \u003cstrong\u003eConstant airflow modulation\u003c\/strong\u003e (except sizes 05 and 08).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuattro®\u003c\/strong\u003e – \u003cstrong\u003eCO₂-based constant airflow modulation\u003c\/strong\u003e (except sizes 05 and 08).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLCD Controller Functions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003eAirflow control\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eTemperature regulation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eTimer commissioning\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eBattery management\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eNight over-ventilation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eLocal controls\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eDefault readings\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFiltration System\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eF7 opacimetric filters\u003c\/strong\u003e for fresh and exhaust air\u003c\/li\u003e\n\u003cli\u003eMounted on \u003cstrong\u003eslides for easy replacement\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDraught-proof sealing\u003c\/strong\u003e ensures airtight efficiency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional additional filters\u003c\/strong\u003e for supply air\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e10\/10e outdoor panels\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e50mm high-density mineral wool insulation\u003c\/strong\u003e (M0 A1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRAL 7035 painted panels\u003c\/strong\u003e with protective film\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGalvanized steel internal panels\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircular connectors with lip seals\u003c\/strong\u003e for airtight installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHinged access doors\u003c\/strong\u003e for easy maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHeat Exchanger\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-efficiency aluminum rotary heat exchanger\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli\u003eMounted in a \u003cstrong\u003erigid slide rack\u003c\/strong\u003e for easy removal and maintenance\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat recovery efficiency over 80%\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eVariable speed for improved midseason performance\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMotors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-energy EC motors\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo motors per unit\u003c\/strong\u003e for optimal performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003eIndoor or outdoor installation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCompact design with a small footprint\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSide duct connections\u003c\/strong\u003e for quick installation\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNo adapters required\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated rooftop panel\u003c\/strong\u003e for indoor\/outdoor use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDuctwork Insulation Recommendations\u003c\/h3\u003e\n\u003cp\u003eFor best performance, we recommend using \u003cstrong\u003eMetal Spiral Ducting and Fittings\u003c\/strong\u003e. To ensure airtightness and durability:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eApply duct sealant\u003c\/strong\u003e to male fittings.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePush components together.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSeal the joint with aluminum duct sealing tape.\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e \u003cstrong\u003eDucting in cold areas (e.g. loft spaces) must be insulated\u003c\/strong\u003e with at least \u003cstrong\u003e25mm thick material\u003c\/strong\u003e with \u003cstrong\u003ethermal conductivity ≤ 0.04W\/(m·K)\u003c\/strong\u003e to prevent condensation.  \u003cstrong\u003eIntake and exhaust ducts should be insulated\u003c\/strong\u003e even if there is no loft space.  \u003cstrong\u003eBubble wrap insulation is not compliant with building regulations.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003eComplete your ventilation system with a range of compatible \u003cstrong\u003econtrols, sensors, silencers, and valves\/diffusers\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGuarantee\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eImportant Information\u003c\/h3\u003e\n\u003cp\u003eThese units are \u003cstrong\u003ebuilt to order\u003c\/strong\u003e. For lead times and further inquiries, please contact our sales team at  \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Caladair Hexamotion 05 D First Eco -","offer_id":53736195719494,"sku":"KCDF025302","price":5929.98,"currency_code":"GBP","in_stock":true},{"title":"Caladair Hexamotion 08 D First Eco -","offer_id":53736195752262,"sku":"KCDF025328","price":6387.74,"currency_code":"GBP","in_stock":true},{"title":"Caladair Hexamotion 15 D First Eco -","offer_id":53736195785030,"sku":"KCDF025354","price":7935.1,"currency_code":"GBP","in_stock":true},{"title":"Caladair Hexamotion 20 D First Eco -","offer_id":53736195817798,"sku":"KCDF025396","price":9155.57,"currency_code":"GBP","in_stock":true},{"title":"Caladair Hexamotion 27 D First Eco -","offer_id":53736195850566,"sku":"KCDF025438","price":10557.88,"currency_code":"GBP","in_stock":true},{"title":"Caladair Hexamotion 35 D First Eco -","offer_id":53736195883334,"sku":"KCDF025480","price":11804.08,"currency_code":"GBP","in_stock":true},{"title":"Caladair Hexamotion 45 D First Eco -","offer_id":53736195916102,"sku":"KCDF025522","price":12985.63,"currency_code":"GBP","in_stock":true},{"title":"Caladair Hexamotion 60 D First Eco -","offer_id":53736195948870,"sku":"KCDF025564","price":14544.3,"currency_code":"GBP","in_stock":true},{"title":"Caladair Hexamotion 80 D First Eco -","offer_id":53736195981638,"sku":"KCDF025606","price":18079.78,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/hexamotion_1.png?v=1732550929"},{"product_id":"caladair-neotime-1","title":"Zehnder Caladair Neotime 600 First Eco MVHR unit","description":"\u003ch3\u003e\u003cstrong\u003eZehnder Caladair Neotime 600 First Eco MVHR Unit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e \u003cstrong\u003eCaladair NEOTIME 600 First Eco\u003c\/strong\u003e - \u003cstrong\u003eCAL01\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003ca href=\"https:\/\/www.zehnder.co.uk\/en\/indoor-ventilation\/solutions\/commercial-ventilation\/zehnder-neotime\"\u003eZehnder Caladair Neotime\u003c\/a\u003e 600 First Eco\u003c\/strong\u003e is a \u003cstrong\u003ecompact and high-efficiency Mechanical Ventilation with Heat Recovery (MVHR) unit\u003c\/strong\u003e designed for \u003cstrong\u003ecommercial applications\u003c\/strong\u003e. It provides advanced zoning, heating \u0026amp; cooling accessories, and intelligent controls to ensure energy-efficient ventilation and optimal indoor air quality.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Zoning Options \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOptional \u003cstrong\u003eelectric duct dampers\u003c\/strong\u003e can be controlled by:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePIR Sensor\u003c\/strong\u003e – Detects occupancy and increases airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO₂ Sensor\u003c\/strong\u003e – Detects high CO₂ levels and adjusts airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall Switch\u003c\/strong\u003e – Manually increases airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Sensor\u003c\/strong\u003e – Adjusts airflow when lights are switched on\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMS (Building Management System)\u003c\/strong\u003e – Controls zoned areas and unit settings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDampers\u003c\/strong\u003e – Configurable to \u003cstrong\u003evarious airflow rates\u003c\/strong\u003e when open or closed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor customization and additional zoning options, contact our sales team at 028 2827 5150\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHeating \u0026amp; Cooling Accessories \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost buildup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Increases room temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Heater\u003c\/strong\u003e – Can be used as a \u003cstrong\u003epre-heater or post-heater\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControllability \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003eDigital Control Panel\u003c\/strong\u003e is available for independent operation without a \u003cstrong\u003eBMS system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eLCD Controller Functions:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWeekly timer\u003c\/li\u003e\n\u003cli\u003eHoliday timer\u003c\/li\u003e\n\u003cli\u003eSummer by-pass \/ Night-time cooling\u003c\/li\u003e\n\u003cli\u003eFault finding\u003c\/li\u003e\n\u003cli\u003eSpeed parameters\u003c\/li\u003e\n\u003cli\u003eFilter indicator\u003c\/li\u003e\n\u003cli\u003eFire alarm integration\u003c\/li\u003e\n\u003cli\u003eTemperature sensors\u003c\/li\u003e\n\u003cli\u003eIntegration via \u003cstrong\u003eModbus, Bacnet, or Web\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFiltration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x F7\u003c\/strong\u003e large-capacity pollen intake filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x G4\u003c\/strong\u003e extract filter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Construction:\u003c\/strong\u003e \u003cstrong\u003eAirtight 10-gauge galvanized steel double-skin panels\u003c\/strong\u003e with \u003cstrong\u003e25mm high-density mineral wool insulation\u003c\/strong\u003e (EN1886)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Face:\u003c\/strong\u003e Pre-lacquered with a protective film in \u003cstrong\u003eRAL 7035\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e Circular branch connections with rubber seals, airtight construction to \u003cstrong\u003eATEC CSTB n° 13-224-12\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e \u003cstrong\u003eCrimped hanging brackets\u003c\/strong\u003e for ceiling mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHeat Exchanger \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly efficient aluminium counter-flow heat exchanger\u003c\/strong\u003e providing up to \u003cstrong\u003e90% heat recovery\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003elifetime use\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMotors \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e2x low-energy, high-efficiency backward curved EC motors\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003eheat and speed protection\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontally mounted\u003c\/strong\u003e on the ceiling or floor with \u003cstrong\u003eadjustable hanging brackets\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnsure the \u003cstrong\u003estructure can support the unit’s weight\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate Drain:\u003c\/strong\u003e \u003cstrong\u003e15mm BSP metal pipe\u003c\/strong\u003e, connect to a drain via a \u003cstrong\u003ewaterless trap\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDimensions \u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeotime 600\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1700\u003c\/td\u003e\n\u003ctd\u003e780\u003c\/td\u003e\n\u003ctd\u003e330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation of Ductwork \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRecommended: \u003cstrong\u003eMetal Spiral Ducting\u003c\/strong\u003e and \u003cstrong\u003efittings\u003c\/strong\u003e for superior strength\u003c\/li\u003e\n\u003cli\u003eFor airtightness and durability, use \u003cstrong\u003eself-sealing fittings\u003c\/strong\u003e or \u003cstrong\u003eDucting Sealant \u0026amp; Aluminium Duct Sealing Tape\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eA full range of \u003cstrong\u003econtrols, sensors, in-line silencers, floor\/wall\/ceiling inlets, and outlet diffusers\u003c\/strong\u003e are available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGuarantee \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e for peace of mind\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlease Note:\u003c\/strong\u003e These units are \u003cstrong\u003ebuilt to order\u003c\/strong\u003e. For lead times, contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736213709126,"sku":"KCDF022976","price":4853.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/zehnder_csy_caladair_neotime_3.jpg?v=1732551428"},{"product_id":"caladair-neotime-zone-900","title":"Zehnder Caladair Neotime 900 First Eco MVHR Units","description":"\u003ch3\u003e\u003cstrong\u003eZehnder Caladair Neotime 900 First Eco MVHR Unit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e \u003cstrong\u003eCaladair NEOTIME 900 First Eco\u003c\/strong\u003e - \u003cstrong\u003eCAL02\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003ca href=\"https:\/\/www.zehnder.co.uk\/en\/indoor-ventilation\/solutions\/commercial-ventilation\/zehnder-neotime\"\u003eZehnder Caladair Neotime\u003c\/a\u003e 900 First Eco\u003c\/strong\u003e is a high-efficiency \u003cstrong\u003eMechanical Ventilation with Heat Recovery (MVHR) unit\u003c\/strong\u003e designed for commercial use. The unit provides \u003cstrong\u003eadvanced zoning control\u003c\/strong\u003e, customizable \u003cstrong\u003eheating \u0026amp; cooling accessories\u003c\/strong\u003e, and \u003cstrong\u003eintelligent controls\u003c\/strong\u003e to optimize energy efficiency and indoor air quality.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Zoning Options \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOptional \u003cstrong\u003eelectric duct dampers\u003c\/strong\u003e for controlling zones via:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePIR Sensor\u003c\/strong\u003e – Detects occupancy and adjusts airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO₂ Sensor\u003c\/strong\u003e – Detects high CO₂ levels and increases airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall Switch\u003c\/strong\u003e – Manually increases airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Sensor\u003c\/strong\u003e – Adjusts airflow when lights are switched on\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMS (Building Management System)\u003c\/strong\u003e – Controls zoned areas and airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDampers\u003c\/strong\u003e – Adjustable airflow rates when open or closed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor more customization options, contact our sales team at 028 2827 5150\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHeating \u0026amp; Cooling Accessories \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost from affecting the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Increases room temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Heater\u003c\/strong\u003e – Can function as \u003cstrong\u003epre-heater or post-heater\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControllability \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003eDigital Control Panel\u003c\/strong\u003e is available for independent operation (without BMS).\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eLCD Controller Functions:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWeekly timer\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHoliday timer\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSummer by-pass\u003c\/strong\u003e \/ \u003cstrong\u003eNight-time cooling\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFault finding\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSpeed parameters\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFilter indicator\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFire alarm integration\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTemperature sensors\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIntegration via \u003cstrong\u003eModbus, Bacnet, or Web\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFiltration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x F7\u003c\/strong\u003e large-capacity \u003cstrong\u003epollen intake filter\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x G4\u003c\/strong\u003e \u003cstrong\u003eextract filter\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Construction:\u003c\/strong\u003e Airtight \u003cstrong\u003e10-gauge galvanized steel double-skin panels\u003c\/strong\u003e with \u003cstrong\u003e25mm high-density mineral wool insulation\u003c\/strong\u003e (EN1886)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Face:\u003c\/strong\u003e Pre-lacquered with protective film in \u003cstrong\u003eRAL 7035\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e Circular branch connections with \u003cstrong\u003erubber seals\u003c\/strong\u003e, airtight construction to \u003cstrong\u003eATEC CSTB n° 13-224-12\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e \u003cstrong\u003eCrimped hanging brackets\u003c\/strong\u003e for ceiling mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHeat Exchanger \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly efficient aluminium counter-flow heat exchanger\u003c\/strong\u003e with up to \u003cstrong\u003e90% heat recovery\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003elifetime use\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMotors \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e2x low-energy, high-efficiency backward curved EC motors\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003eheat and speed protection\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontally mounted\u003c\/strong\u003e on the ceiling or floor with \u003cstrong\u003eadjustable hanging brackets\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnsure the \u003cstrong\u003estructure can support the unit’s weight\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate Drain:\u003c\/strong\u003e \u003cstrong\u003e15mm BSP metal pipe\u003c\/strong\u003e, connect to a drain via \u003cstrong\u003ewaterless trap\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDimensions \u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeotime 900\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2020\u003c\/td\u003e\n\u003ctd\u003e965\u003c\/td\u003e\n\u003ctd\u003e415\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation of Ductwork \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRecommended: \u003cstrong\u003eMetal Spiral Ducting\u003c\/strong\u003e and \u003cstrong\u003efittings\u003c\/strong\u003e for superior strength\u003c\/li\u003e\n\u003cli\u003eFor airtightness and durability, use \u003cstrong\u003eself-sealing fittings\u003c\/strong\u003e or \u003cstrong\u003eDucting Sealant \u0026amp; Aluminium Duct Sealing Tape\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eA full range of \u003cstrong\u003econtrols, sensors, in-line silencers, floor\/wall\/ceiling inlets, and outlet diffusers\u003c\/strong\u003e available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGuarantee \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlease Note:\u003c\/strong\u003e These units are \u003cstrong\u003ebuilt to order\u003c\/strong\u003e. For lead times, contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736214593862,"sku":"KCDF023092","price":6007.81,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/zehnder_csy_caladair_neotime_4.jpg?v=1732551471"},{"product_id":"neotime-zone-1300","title":"Zehnder Caladair Neotime 1300 First Eco MVHR Units","description":"\u003ch3\u003e\u003cstrong\u003eZehnder Caladair Neotime 1300 First Eco MVHR Unit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e \u003cstrong\u003eCaladair NEOTIME 1300 First Eco\u003c\/strong\u003e - \u003cstrong\u003eCAL03\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003ca href=\"https:\/\/www.zehnder.co.uk\/en\/indoor-ventilation\/solutions\/commercial-ventilation\/zehnder-neotime\"\u003eZehnder Caladair Neotime\u003c\/a\u003e 1300 First Eco\u003c\/strong\u003e is a \u003cstrong\u003ehigh-efficiency Mechanical Ventilation with Heat Recovery (MVHR) unit\u003c\/strong\u003e designed for commercial applications. It offers \u003cstrong\u003eadvanced zoning options, heating \u0026amp; cooling accessories, and smart controls\u003c\/strong\u003e for optimal \u003cstrong\u003eenergy savings and indoor air quality improvements\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Zoning Options \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOptional \u003cstrong\u003eelectric duct dampers\u003c\/strong\u003e can be controlled by:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePIR Sensor\u003c\/strong\u003e – Detects occupancy and increases airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO₂ Sensor\u003c\/strong\u003e – Detects high CO₂ levels and adjusts airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall Switch\u003c\/strong\u003e – Manually increases airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Sensor\u003c\/strong\u003e – Adjusts airflow when lights are switched on\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMS (Building Management System)\u003c\/strong\u003e – Controls zoned areas and unit settings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDampers\u003c\/strong\u003e – Configurable to \u003cstrong\u003evarious airflow rates\u003c\/strong\u003e when open or closed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor customization and additional zoning options, contact our sales team at 028 2827 5150\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHeating \u0026amp; Cooling Accessories \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost buildup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Increases room temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Heater\u003c\/strong\u003e – Can be used as a \u003cstrong\u003epre-heater or post-heater\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControllability \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003eDigital Control Panel\u003c\/strong\u003e is available for independent operation without a \u003cstrong\u003eBMS system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eLCD Controller Functions:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWeekly timer\u003c\/li\u003e\n\u003cli\u003eHoliday timer\u003c\/li\u003e\n\u003cli\u003eSummer by-pass \/ Night-time cooling\u003c\/li\u003e\n\u003cli\u003eFault finding\u003c\/li\u003e\n\u003cli\u003eSpeed parameters\u003c\/li\u003e\n\u003cli\u003eFilter indicator\u003c\/li\u003e\n\u003cli\u003eFire alarm integration\u003c\/li\u003e\n\u003cli\u003eTemperature sensors\u003c\/li\u003e\n\u003cli\u003eIntegration via \u003cstrong\u003eModbus, Bacnet, or Web\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFiltration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x F7\u003c\/strong\u003e large-capacity pollen intake filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x G4\u003c\/strong\u003e extract filter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Construction:\u003c\/strong\u003e \u003cstrong\u003eAirtight 10-gauge galvanized steel double-skin panels\u003c\/strong\u003e with \u003cstrong\u003e25mm high-density mineral wool insulation\u003c\/strong\u003e (EN1886)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Face:\u003c\/strong\u003e Pre-lacquered with a protective film in \u003cstrong\u003eRAL 7035\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e Circular branch connections with rubber seals, airtight construction to \u003cstrong\u003eATEC CSTB n° 13-224-12\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e \u003cstrong\u003eCrimped hanging brackets\u003c\/strong\u003e for ceiling mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHeat Exchanger \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly efficient aluminium counter-flow heat exchanger\u003c\/strong\u003e providing up to \u003cstrong\u003e90% heat recovery\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003elifetime use\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMotors \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e2x low-energy, high-efficiency backward curved EC motors\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003eheat and speed protection\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontally mounted\u003c\/strong\u003e on the ceiling or floor with \u003cstrong\u003eadjustable hanging brackets\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnsure the \u003cstrong\u003estructure can support the unit’s weight\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate Drain:\u003c\/strong\u003e \u003cstrong\u003e15mm BSP metal pipe\u003c\/strong\u003e, connect to a drain via a \u003cstrong\u003ewaterless trap\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDimensions \u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeotime 1300\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2190\u003c\/td\u003e\n\u003ctd\u003e1220\u003c\/td\u003e\n\u003ctd\u003e415\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation of Ductwork \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRecommended: \u003cstrong\u003eMetal Spiral Ducting\u003c\/strong\u003e and \u003cstrong\u003efittings\u003c\/strong\u003e for superior strength\u003c\/li\u003e\n\u003cli\u003eFor airtightness and durability, use \u003cstrong\u003eself-sealing fittings\u003c\/strong\u003e or \u003cstrong\u003eDucting Sealant \u0026amp; Aluminium Duct Sealing Tape\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eA full range of \u003cstrong\u003econtrols, sensors, in-line silencers, floor\/wall\/ceiling inlets, and outlet diffusers\u003c\/strong\u003e are available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGuarantee \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e for peace of mind\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlease Note:\u003c\/strong\u003e These units are \u003cstrong\u003ebuilt to order\u003c\/strong\u003e. For lead times, contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736214626630,"sku":"KCDF023169","price":7919.78,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/zehnder_csy_caladair_neotime.jpg?v=1732551463"},{"product_id":"neotime-smart-zone-1800","title":"Zehnder Caladair Neotime 1800 First Eco MVHR Units","description":"\u003ch3\u003e\u003cstrong\u003eZehnder Caladair Neotime 1800 First Eco MVHR Unit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e \u003cstrong\u003eCaladair NEOTIME 1800 First Eco\u003c\/strong\u003e - \u003cstrong\u003eCAL04\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003ca href=\"https:\/\/www.zehnder.co.uk\/en\/indoor-ventilation\/solutions\/commercial-ventilation\/zehnder-neotime\"\u003eZehnder Caladair Neotime\u003c\/a\u003e 1800 First Eco\u003c\/strong\u003e is a \u003cstrong\u003ehigh-efficiency Mechanical Ventilation with Heat Recovery (MVHR) unit\u003c\/strong\u003e designed for \u003cstrong\u003ecommercial applications\u003c\/strong\u003e. It offers \u003cstrong\u003eadvanced zoning options, heating \u0026amp; cooling accessories, and intelligent controls\u003c\/strong\u003e for \u003cstrong\u003eenergy-efficient ventilation\u003c\/strong\u003e and \u003cstrong\u003eoptimal indoor air quality\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Zoning Options \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOptional \u003cstrong\u003eelectric duct dampers\u003c\/strong\u003e can be controlled by:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePIR Sensor\u003c\/strong\u003e – Detects occupancy and increases airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO₂ Sensor\u003c\/strong\u003e – Detects high CO₂ levels and adjusts airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall Switch\u003c\/strong\u003e – Manually increases airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Sensor\u003c\/strong\u003e – Adjusts airflow when lights are switched on\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMS (Building Management System)\u003c\/strong\u003e – Controls zoned areas and unit settings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDampers\u003c\/strong\u003e – Configurable to \u003cstrong\u003evarious airflow rates\u003c\/strong\u003e when open or closed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor customization and additional zoning options, contact our sales team at 028 2827 5150\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHeating \u0026amp; Cooling Accessories \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost buildup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Increases room temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Heater\u003c\/strong\u003e – Can be used as a \u003cstrong\u003epre-heater or post-heater\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControllability \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003eDigital Control Panel\u003c\/strong\u003e is available for independent operation without a \u003cstrong\u003eBMS system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eLCD Controller Functions:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWeekly timer\u003c\/li\u003e\n\u003cli\u003eHoliday timer\u003c\/li\u003e\n\u003cli\u003eSummer by-pass \/ Night-time cooling\u003c\/li\u003e\n\u003cli\u003eFault finding\u003c\/li\u003e\n\u003cli\u003eSpeed parameters\u003c\/li\u003e\n\u003cli\u003eFilter indicator\u003c\/li\u003e\n\u003cli\u003eFire alarm integration\u003c\/li\u003e\n\u003cli\u003eTemperature sensors\u003c\/li\u003e\n\u003cli\u003eIntegration via \u003cstrong\u003eModbus, Bacnet, or Web\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFiltration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x F7\u003c\/strong\u003e large-capacity pollen intake filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x G4\u003c\/strong\u003e extract filter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Construction:\u003c\/strong\u003e \u003cstrong\u003eAirtight 10-gauge galvanized steel double-skin panels\u003c\/strong\u003e with \u003cstrong\u003e25mm high-density mineral wool insulation\u003c\/strong\u003e (EN1886)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Face:\u003c\/strong\u003e Pre-lacquered with a protective film in \u003cstrong\u003eRAL 7035\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e Circular branch connections with rubber seals, airtight construction to \u003cstrong\u003eATEC CSTB n° 13-224-12\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e \u003cstrong\u003eCrimped hanging brackets\u003c\/strong\u003e for ceiling mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHeat Exchanger \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly efficient aluminium counter-flow heat exchanger\u003c\/strong\u003e providing up to \u003cstrong\u003e90% heat recovery\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003elifetime use\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMotors \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e2x low-energy, high-efficiency backward curved EC motors\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003eheat and speed protection\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontally mounted\u003c\/strong\u003e on the ceiling or floor with \u003cstrong\u003eadjustable hanging brackets\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnsure the \u003cstrong\u003estructure can support the unit’s weight\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate Drain:\u003c\/strong\u003e \u003cstrong\u003e15mm BSP metal pipe\u003c\/strong\u003e, connect to a drain via a \u003cstrong\u003ewaterless trap\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDimensions \u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeotime 1800\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2275\u003c\/td\u003e\n\u003ctd\u003e1200\u003c\/td\u003e\n\u003ctd\u003e495\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation of Ductwork \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRecommended: \u003cstrong\u003eMetal Spiral Ducting\u003c\/strong\u003e and \u003cstrong\u003efittings\u003c\/strong\u003e for superior strength\u003c\/li\u003e\n\u003cli\u003eFor airtightness and durability, use \u003cstrong\u003eself-sealing fittings\u003c\/strong\u003e or \u003cstrong\u003eDucting Sealant \u0026amp; Aluminium Duct Sealing Tape\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eA full range of \u003cstrong\u003econtrols, sensors, in-line silencers, floor\/wall\/ceiling inlets, and outlet diffusers\u003c\/strong\u003e are available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGuarantee \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e for peace of mind\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlease Note:\u003c\/strong\u003e These units are \u003cstrong\u003ebuilt to order\u003c\/strong\u003e. For lead times, contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736214692166,"sku":"KCDF023198","price":8889.08,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/zehnder_csy_caladair_neotime_1.jpg?v=1732551475"},{"product_id":"neotime-2500-smart-zone","title":"Zehnder Caladair Neotime 2500 First Eco MVHR Unit","description":"\u003ch3\u003e\u003cstrong\u003eZehnder Caladair Neotime 2500 First Eco MVHR Unit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e \u003cstrong\u003eCaladair NEOTIME 2500 First Eco\u003c\/strong\u003e - \u003cstrong\u003eCAL05\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003ca href=\"https:\/\/www.zehnder.co.uk\/en\/indoor-ventilation\/solutions\/commercial-ventilation\/zehnder-neotime\"\u003eZehnder Caladair Neotime\u003c\/a\u003e 2500 First Eco\u003c\/strong\u003e is a \u003cstrong\u003ehigh-efficiency Mechanical Ventilation with Heat Recovery (MVHR) unit\u003c\/strong\u003e designed for \u003cstrong\u003ecommercial applications\u003c\/strong\u003e. It offers \u003cstrong\u003eadvanced zoning options, heating \u0026amp; cooling accessories, and intelligent controls\u003c\/strong\u003e for \u003cstrong\u003eenergy-efficient ventilation\u003c\/strong\u003e and \u003cstrong\u003eoptimal indoor air quality\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Zoning Options \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOptional \u003cstrong\u003eelectric duct dampers\u003c\/strong\u003e can be controlled by:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePIR Sensor\u003c\/strong\u003e – Detects occupancy and increases airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO₂ Sensor\u003c\/strong\u003e – Detects high CO₂ levels and adjusts airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall Switch\u003c\/strong\u003e – Manually increases airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Sensor\u003c\/strong\u003e – Adjusts airflow when lights are switched on\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMS (Building Management System)\u003c\/strong\u003e – Controls zoned areas and unit settings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDampers\u003c\/strong\u003e – Configurable to \u003cstrong\u003evarious airflow rates\u003c\/strong\u003e when open or closed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor customization and additional zoning options, contact our sales team at 028 2827 5150\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHeating \u0026amp; Cooling Accessories \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost buildup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Increases room temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Heater\u003c\/strong\u003e – Can be used as a \u003cstrong\u003epre-heater or post-heater\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControllability \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003eDigital Control Panel\u003c\/strong\u003e is available for independent operation without a \u003cstrong\u003eBMS system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eLCD Controller Functions:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWeekly timer\u003c\/li\u003e\n\u003cli\u003eHoliday timer\u003c\/li\u003e\n\u003cli\u003eSummer by-pass \/ Night-time cooling\u003c\/li\u003e\n\u003cli\u003eFault finding\u003c\/li\u003e\n\u003cli\u003eSpeed parameters\u003c\/li\u003e\n\u003cli\u003eFilter indicator\u003c\/li\u003e\n\u003cli\u003eFire alarm integration\u003c\/li\u003e\n\u003cli\u003eTemperature sensors\u003c\/li\u003e\n\u003cli\u003eIntegration via \u003cstrong\u003eModbus, Bacnet, or Web\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFiltration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x F7\u003c\/strong\u003e large-capacity pollen intake filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x G4\u003c\/strong\u003e extract filter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Construction:\u003c\/strong\u003e \u003cstrong\u003eAirtight 10-gauge galvanized steel double-skin panels\u003c\/strong\u003e with \u003cstrong\u003e25mm high-density mineral wool insulation\u003c\/strong\u003e (EN1886)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Face:\u003c\/strong\u003e Pre-lacquered with a protective film in \u003cstrong\u003eRAL 7035\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e Circular branch connections with rubber seals, airtight construction to \u003cstrong\u003eATEC CSTB n° 13-224-12\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e \u003cstrong\u003eCrimped hanging brackets\u003c\/strong\u003e for ceiling mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHeat Exchanger \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly efficient aluminium counter-flow heat exchanger\u003c\/strong\u003e providing up to \u003cstrong\u003e90% heat recovery\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003elifetime use\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMotors \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e2x low-energy, high-efficiency backward curved EC motors\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003eheat and speed protection\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontally mounted\u003c\/strong\u003e on the ceiling or floor with \u003cstrong\u003eadjustable hanging brackets\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnsure the \u003cstrong\u003estructure can support the unit’s weight\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate Drain:\u003c\/strong\u003e \u003cstrong\u003e15mm BSP metal pipe\u003c\/strong\u003e, connect to a drain via a \u003cstrong\u003ewaterless trap\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDimensions \u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeotime 2500\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2395\u003c\/td\u003e\n\u003ctd\u003e1740\u003c\/td\u003e\n\u003ctd\u003e495\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation of Ductwork \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRecommended: \u003cstrong\u003eMetal Spiral Ducting\u003c\/strong\u003e and \u003cstrong\u003efittings\u003c\/strong\u003e for superior strength\u003c\/li\u003e\n\u003cli\u003eFor airtightness and durability, use \u003cstrong\u003eself-sealing fittings\u003c\/strong\u003e or \u003cstrong\u003eDucting Sealant \u0026amp; Aluminium Duct Sealing Tape\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eA full range of \u003cstrong\u003econtrols, sensors, in-line silencers, floor\/wall\/ceiling inlets, and outlet diffusers\u003c\/strong\u003e are available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGuarantee \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e for peace of mind\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlease Note:\u003c\/strong\u003e These units are \u003cstrong\u003ebuilt to order\u003c\/strong\u003e. For lead times, contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736214757702,"sku":"KCDF023217","price":10202.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/zehnder_csy_caladair_neotime_2.jpg?v=1732551488"},{"product_id":"carma-smart-zone-9008","title":"Zehnder Caladair Carma 9008 First Eco","description":"\u003cp\u003e\u003cstrong\u003eZehnder Caladair Carma 9008 First Eco\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e Caladair CARMA 9008 L First Eco - CAL12\u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.zehnder.co.uk\/en\/indoor-ventilation\/solutions\/commercial-ventilation\/zehnder-carma\" target=\"_blank\"\u003eThe Zehnder Caladair Carma\u003c\/a\u003e 9008 First Eco is a high-efficiency commercial ventilation unit with advanced zoning options and controllability. Ideal for improving air quality, this unit is built to order and offers customizable features for optimal performance.\u003c\/p\u003e\n\u003ch3\u003eAdditional Zoning Options\u003c\/h3\u003e\n\u003cp\u003eEnhance airflow control with optional extras, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePIR Sensor\u003c\/strong\u003e – Detects occupancy and increases airflow automatically.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Sensor\u003c\/strong\u003e – Adjusts airflow based on CO2 levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall Switch\u003c\/strong\u003e – Manually increases airflow at the press of a switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Integration\u003c\/strong\u003e – Triggers increased airflow when lights are turned on.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMS Control\u003c\/strong\u003e – Adjusts zoned areas and unit functions via a Building Management System.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Dampers\u003c\/strong\u003e – Configure airflow rates for open\/closed positions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cem\u003eFor more information on adding these extras, contact us at 028 2827 5150.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eHeating \u0026amp; Cooling Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost from affecting the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Enhances room temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Heater\u003c\/strong\u003e – Functions as a pre or post heater.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eControllability\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003edigital control panel\u003c\/strong\u003e is available for users not integrating with a BMS system. Features include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWeekly and holiday timers\u003c\/li\u003e\n\u003cli\u003eSummer bypass \u0026amp; nighttime cooling\u003c\/li\u003e\n\u003cli\u003eFault diagnostics\u003c\/li\u003e\n\u003cli\u003eSpeed parameter settings\u003c\/li\u003e\n\u003cli\u003eFilter indicator\u003c\/li\u003e\n\u003cli\u003eFire alarm integration\u003c\/li\u003e\n\u003cli\u003eTemperature sensors\u003c\/li\u003e\n\u003cli\u003eCompatible with Modbus, Bacnet, or web integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFiltration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e1x F7 large capacity pollen intake filter\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1x G4 extract filter\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAirtight \u003cstrong\u003e10-gauge galvanized steel double-skin panels\u003c\/strong\u003e with \u003cstrong\u003e25mm high-density mineral wool insulation\u003c\/strong\u003e (EN1886 compliant).\u003c\/li\u003e\n\u003cli\u003eProtective \u003cstrong\u003epre-lacquered external finish\u003c\/strong\u003e (RAL 7035).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircular branch connections\u003c\/strong\u003e with rubber seals for airtight construction (ATEC CSTB n° 13-224-12).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrimped hanging brackets\u003c\/strong\u003e for ceiling mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHeat Exchanger\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly efficient aluminum counter-flow heat exchanger\u003c\/strong\u003e providing up to \u003cstrong\u003e90% heat recovery\u003c\/strong\u003e for a \u003cstrong\u003elifetime of use\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMotors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2x low-energy, high-efficiency backward curved EC motors\u003c\/strong\u003e with built-in \u003cstrong\u003eheat and speed protection\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVertical or horizontal mounting\u003c\/strong\u003e (excluding CARMA 9048 and 9070).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor or outdoor installation\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFalse ceiling installation\u003c\/strong\u003e (models 9008 to 9035).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate drain point\u003c\/strong\u003e (15mm BSP metal pipe, to be connected via a waterless trap).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended ductwork:\u003c\/strong\u003e Metal spiral ducting and fittings for superior strength.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e9008\u003c\/td\u003e\n\u003ctd\u003e2010\u003c\/td\u003e\n\u003ctd\u003e915\u003c\/td\u003e\n\u003ctd\u003e505\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003eCompatible with a full range of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDucting systems\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eControls \u0026amp; sensors\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIn-line silencers\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFloor, wall, and ceiling diffusers\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGuarantee\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cem\u003ePlease Note:\u003c\/em\u003e These units are built to order. For lead times and availability, contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736215019846,"sku":"KCDF026170","price":7581.34,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/zehnder_csy_caladair_carma.jpg?v=1732551518"},{"product_id":"carma-smart-zone-9010","title":"Zehnder Caladair Carma 9010 First Eco","description":"\u003cp\u003e\u003cstrong\u003eZehnder Caladair Carma 9010 First Eco\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e Caladair CARMA 9010 L First Eco - CAL13\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.zehnder.co.uk\/en\/indoor-ventilation\/solutions\/commercial-ventilation\/zehnder-carma\" target=\"_blank\" rel=\"noopener\"\u003eThe Zehnder Caladair Carma\u003c\/a\u003e 9010 First Eco is a high-efficiency commercial ventilation unit with advanced zoning options and controllability. Ideal for improving air quality, this unit is built to order and offers customizable features for optimal performance.\u003c\/p\u003e\n\u003ch3\u003eAdditional Zoning Options\u003c\/h3\u003e\n\u003cp\u003eEnhance airflow control with optional extras, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePIR Sensor\u003c\/strong\u003e – Detects occupancy and increases airflow automatically.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Sensor\u003c\/strong\u003e – Adjusts airflow based on CO2 levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall Switch\u003c\/strong\u003e – Manually increases airflow at the press of a switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Integration\u003c\/strong\u003e – Triggers increased airflow when lights are turned on.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMS Control\u003c\/strong\u003e – Adjusts zoned areas and unit functions via a Building Management System.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Dampers\u003c\/strong\u003e – Configure airflow rates for open\/closed positions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cem\u003eFor more information on adding these extras, contact us at 028 2827 5150.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eHeating \u0026amp; Cooling Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost from affecting the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Enhances room temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Heater\u003c\/strong\u003e – Functions as a pre or post heater.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eControllability\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003edigital control panel\u003c\/strong\u003e is available for users not integrating with a BMS system. Features include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWeekly and holiday timers\u003c\/li\u003e\n\u003cli\u003eSummer bypass \u0026amp; nighttime cooling\u003c\/li\u003e\n\u003cli\u003eFault diagnostics\u003c\/li\u003e\n\u003cli\u003eSpeed parameter settings\u003c\/li\u003e\n\u003cli\u003eFilter indicator\u003c\/li\u003e\n\u003cli\u003eFire alarm integration\u003c\/li\u003e\n\u003cli\u003eTemperature sensors\u003c\/li\u003e\n\u003cli\u003eCompatible with Modbus, Bacnet, or web integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFiltration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e1x F7 large capacity pollen intake filter\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1x G4 extract filter\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAirtight \u003cstrong\u003e10-gauge galvanized steel double-skin panels\u003c\/strong\u003e with \u003cstrong\u003e25mm high-density mineral wool insulation\u003c\/strong\u003e (EN1886 compliant).\u003c\/li\u003e\n\u003cli\u003eProtective \u003cstrong\u003epre-lacquered external finish\u003c\/strong\u003e (RAL 7035).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircular branch connections\u003c\/strong\u003e with rubber seals for airtight construction (ATEC CSTB n° 13-224-12).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrimped hanging brackets\u003c\/strong\u003e for ceiling mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHeat Exchanger\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly efficient aluminum counter-flow heat exchanger\u003c\/strong\u003e providing up to \u003cstrong\u003e90% heat recovery\u003c\/strong\u003e for a \u003cstrong\u003elifetime of use\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMotors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2x low-energy, high-efficiency backward curved EC motors\u003c\/strong\u003e with built-in \u003cstrong\u003eheat and speed protection\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVertical or horizontal mounting\u003c\/strong\u003e (excluding CARMA 9048 and 9070).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor or outdoor installation\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFalse ceiling installation\u003c\/strong\u003e (models 9008 to 9035).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate drain point\u003c\/strong\u003e (15mm BSP metal pipe, to be connected via a waterless trap).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended ductwork:\u003c\/strong\u003e Metal spiral ducting and fittings for superior strength.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e9010\u003c\/td\u003e\n\u003ctd\u003e2010\u003c\/td\u003e\n\u003ctd\u003e915\u003c\/td\u003e\n\u003ctd\u003e505\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003eCompatible with a full range of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDucting systems\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eControls \u0026amp; sensors\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIn-line silencers\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFloor, wall, and ceiling diffusers\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGuarantee\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cem\u003ePlease Note:\u003c\/em\u003e These units are built to order. For lead times and availability, contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736215118150,"sku":"KCDF026246","price":8586.01,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/zehnder_csy_caladair_carma_1.jpg?v=1732551530"},{"product_id":"carma-smart-zone-9016","title":"Zehnder Caladair Carma 9016 First Eco","description":"\u003cp\u003e\u003cstrong\u003eZehnder Caladair Carma 9016 First Eco\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e Caladair CARMA 9016 L First Eco - CDF026370\u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.zehnder.co.uk\/en\/indoor-ventilation\/solutions\/commercial-ventilation\/zehnder-carma\" target=\"_blank\"\u003eThe Zehnder Caladair Carma\u003c\/a\u003e 9016 First Eco is a high-efficiency commercial ventilation unit with advanced zoning options and controllability. Designed for improved air quality, this unit is built to order and offers customizable features for optimal performance.\u003c\/p\u003e\n\u003ch3\u003eAdditional Zoning Options\u003c\/h3\u003e\n\u003cp\u003eEnhance airflow control with optional extras, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePIR Sensor\u003c\/strong\u003e – Detects occupancy and increases airflow automatically.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Sensor\u003c\/strong\u003e – Adjusts airflow based on CO2 levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall Switch\u003c\/strong\u003e – Manually increases airflow at the press of a switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Integration\u003c\/strong\u003e – Triggers increased airflow when lights are turned on.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMS Control\u003c\/strong\u003e – Adjusts zoned areas and unit functions via a Building Management System.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Dampers\u003c\/strong\u003e – Configure airflow rates for open\/closed positions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cem\u003eFor more information on adding these extras, contact us at 028 2827 5150.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eHeating \u0026amp; Cooling Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost from affecting the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Enhances room temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Heater\u003c\/strong\u003e – Functions as a pre or post heater.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eControllability\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003edigital control panel\u003c\/strong\u003e is available for users not integrating with a BMS system. Features include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWeekly and holiday timers\u003c\/li\u003e\n\u003cli\u003eSummer bypass \u0026amp; nighttime cooling\u003c\/li\u003e\n\u003cli\u003eFault diagnostics\u003c\/li\u003e\n\u003cli\u003eSpeed parameter settings\u003c\/li\u003e\n\u003cli\u003eFilter indicator\u003c\/li\u003e\n\u003cli\u003eFire alarm integration\u003c\/li\u003e\n\u003cli\u003eTemperature sensors\u003c\/li\u003e\n\u003cli\u003eCompatible with Modbus, Bacnet, or web integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFiltration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e1x F7 large capacity pollen intake filter\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1x G4 extract filter\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAirtight \u003cstrong\u003e10-gauge galvanized steel double-skin panels\u003c\/strong\u003e with \u003cstrong\u003e25mm high-density mineral wool insulation\u003c\/strong\u003e (EN1886 compliant).\u003c\/li\u003e\n\u003cli\u003eProtective \u003cstrong\u003epre-lacquered external finish\u003c\/strong\u003e (RAL 7035).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircular branch connections\u003c\/strong\u003e with rubber seals for airtight construction (ATEC CSTB n° 13-224-12).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrimped hanging brackets\u003c\/strong\u003e for ceiling mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHeat Exchanger\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly efficient aluminum counter-flow heat exchanger\u003c\/strong\u003e providing up to \u003cstrong\u003e90% heat recovery\u003c\/strong\u003e for a \u003cstrong\u003elifetime of use\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMotors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2x low-energy, high-efficiency backward curved EC motors\u003c\/strong\u003e with built-in \u003cstrong\u003eheat and speed protection\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVertical or horizontal mounting\u003c\/strong\u003e (excluding CARMA 9048 and 9070).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor or outdoor installation\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFalse ceiling installation\u003c\/strong\u003e (models 9008 to 9035).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate drain point\u003c\/strong\u003e (15mm BSP metal pipe, to be connected via a waterless trap).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended ductwork:\u003c\/strong\u003e Metal spiral ducting and fittings for superior strength.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e9016\u003c\/td\u003e\n\u003ctd\u003e2230\u003c\/td\u003e\n\u003ctd\u003e1115\u003c\/td\u003e\n\u003ctd\u003e605\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003eCompatible with a full range of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDucting systems\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eControls \u0026amp; sensors\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIn-line silencers\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFloor, wall, and ceiling diffusers\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGuarantee\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cem\u003ePlease Note:\u003c\/em\u003e These units are built to order. For lead times and availability, contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736215150918,"sku":"KCDF026370","price":10134.32,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/zehnder_csy_caladair_carma_2.jpg?v=1732551483"},{"product_id":"carma-smart-zone-9023","title":"Zehnder Caladair Carma 9023 First Eco","description":"\u003cp\u003e\u003cstrong\u003eZehnder Caladair Carma 9023 First Eco\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e Caladair CARMA 9023 L First Eco - CAL15\u003c\/p\u003e\n\u003ch3\u003eAdditional Zoning Options\u003c\/h3\u003e\n\u003cp\u003eEnhance control over different zones with optional extras for Caladair Commercial Units. Zones can be managed using electric duct dampers operated by:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePIR Sensor\u003c\/strong\u003e – Detects occupancy and increases airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Sensor\u003c\/strong\u003e – Detects high CO2 levels and increases airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall Switch\u003c\/strong\u003e – Manually increase airflow by pressing the switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Activation\u003c\/strong\u003e – Increases airflow when the light is turned on\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMS Integration\u003c\/strong\u003e – Adjust zoned areas and unit control via the BMS system Dampers can be set to various airflow rates when open or closed. For more details on adding these extras to your system, please contact us at  \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHeating \u0026amp; Cooling Accessories\u003c\/h3\u003e\n\u003cp\u003eEnhance your unit with optional heating and cooling accessories:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost from affecting the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Increases room temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Heater\u003c\/strong\u003e – Can be used as a pre or post heater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eControllability\u003c\/h3\u003e\n\u003cp\u003eFor units not connected to a BMS system, a \u003cstrong\u003eDigital Control Panel\u003c\/strong\u003e is available with an \u003cstrong\u003eLCD Controller\u003c\/strong\u003e offering features such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWeekly \u0026amp; holiday timer\u003c\/li\u003e\n\u003cli\u003eSummer bypass \u0026amp; night-time cooling\u003c\/li\u003e\n\u003cli\u003eFault diagnostics \u003c\/li\u003e\n\u003cli\u003eSpeed parameters \u003c\/li\u003e\n\u003cli\u003eFilter indicator\u003c\/li\u003e\n\u003cli\u003eFire alarm integration \u003c\/li\u003e\n\u003cli\u003eTemperature sensors \u003c\/li\u003e\n\u003cli\u003eIntegration via \u003cstrong\u003eModbus, Bacnet, or Web\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFiltration System\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e1x F7 large capacity pollen intake filter\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1x G4 extract filter\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAirtight \u003cstrong\u003e10-gauge galvanized steel\u003c\/strong\u003e double-skin panels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e25mm high-density mineral wool insulation\u003c\/strong\u003e (EN1886 compliant)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRAL 7035\u003c\/strong\u003e pre-lacquered external face with protective film\u003c\/li\u003e\n\u003cli\u003eCircular branch connections with rubber seals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirtight construction\u003c\/strong\u003e (ATEC CSTB n° 13-224-12)\u003c\/li\u003e\n\u003cli\u003eCrimped hanging brackets for \u003cstrong\u003eceiling mounting\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHeat Exchanger\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHighly efficient \u003cstrong\u003ealuminum counter-flow heat exchanger\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eProvides up to \u003cstrong\u003e90% heat recovery\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003elifetime use\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMotors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e2x Low-energy, high-efficiency backward-curved EC motors\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003eheat and speed protection\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCan be installed \u003cstrong\u003evertically or horizontally\u003c\/strong\u003e (except CARMA 9048 and 9070)\u003c\/li\u003e\n\u003cli\u003eSuitable for \u003cstrong\u003eindoor or outdoor\u003c\/strong\u003e installation\u003c\/li\u003e\n\u003cli\u003eFits in \u003cstrong\u003efalse ceilings\u003c\/strong\u003e (models 9008 to 9035)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15mm BSP metal condensate drain point\u003c\/strong\u003e for easy drainage (requires waterless trap connection)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Ductwork\u003c\/h3\u003e\n\u003cp\u003eFor superior strength, we recommend using \u003cstrong\u003eMetal Spiral Ducting and Fittings\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e9023\u003c\/td\u003e\n\u003ctd\u003e2345\u003c\/td\u003e\n\u003ctd\u003e1315\u003c\/td\u003e\n\u003ctd\u003e705\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003eComplete your installation with a range of compatible accessories:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDucting systems\u003c\/li\u003e\n\u003cli\u003eSensors\u003c\/li\u003e\n\u003cli\u003eIn-line silencers\u003c\/li\u003e\n\u003cli\u003eFloor, wall, and ceiling inlet\/outlet diffusers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGuarantee\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eImportant Information\u003c\/h3\u003e\n\u003cp\u003eThese units are \u003cstrong\u003ebuilt to order\u003c\/strong\u003e. For lead times and further inquiries, please contact our sales team at  \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736215216454,"sku":"KCDF026514","price":12008.54,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/zehnder_csy_caladair_carma_3.jpg?v=1732551496"},{"product_id":"carma-smart-zone-9035","title":"Zehnder Caladair Carma 9035 First Eco","description":"\u003cp\u003e\u003cstrong\u003eZehnder Caladair Carma 9035 First Eco\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e Caladair CARMA 9035 L First Eco - CAL16\u003c\/p\u003e\n\u003ch3\u003eAdditional Zoning Options\u003c\/h3\u003e\n\u003cp\u003eEnhance control over different zones with optional extras for Caladair Commercial Units. Zones can be managed using electric duct dampers operated by:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePIR Sensor\u003c\/strong\u003e – Detects occupancy and increases airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Sensor\u003c\/strong\u003e – Detects high CO2 levels and increases airflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall Switch\u003c\/strong\u003e – Manually increase airflow by pressing the switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Activation\u003c\/strong\u003e – Increases airflow when the light is turned on\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMS Integration\u003c\/strong\u003e – Adjust zoned areas and unit control via the BMS system Dampers can be set to various airflow rates when open or closed. For more details on adding these extras to your system, please contact us at  \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHeating \u0026amp; Cooling Accessories\u003c\/h3\u003e\n\u003cp\u003eEnhance your unit with optional heating and cooling accessories:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost from affecting the unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Increases room temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Heater\u003c\/strong\u003e – Can be used as a pre or post heater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eControllability\u003c\/h3\u003e\n\u003cp\u003eFor units not connected to a BMS system, a \u003cstrong\u003eDigital Control Panel\u003c\/strong\u003e is available with an \u003cstrong\u003eLCD Controller\u003c\/strong\u003e offering features such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWeekly \u0026amp; holiday timer\u003c\/li\u003e\n\u003cli\u003eSummer bypass \u0026amp; night-time cooling\u003c\/li\u003e\n\u003cli\u003eFault diagnostics \u003c\/li\u003e\n\u003cli\u003eSpeed parameters \u003c\/li\u003e\n\u003cli\u003eFilter indicator\u003c\/li\u003e\n\u003cli\u003eFire alarm integration \u003c\/li\u003e\n\u003cli\u003eTemperature sensors \u003c\/li\u003e\n\u003cli\u003eIntegration via \u003cstrong\u003eModbus, Bacnet, or Web\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFiltration System\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e1x F7 large capacity pollen intake filter\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1x G4 extract filter\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAirtight \u003cstrong\u003e10-gauge galvanized steel\u003c\/strong\u003e double-skin panels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e25mm high-density mineral wool insulation\u003c\/strong\u003e (EN1886 compliant)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRAL 7035\u003c\/strong\u003e pre-lacquered external face with protective film\u003c\/li\u003e\n\u003cli\u003eCircular branch connections with rubber seals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirtight construction\u003c\/strong\u003e (ATEC CSTB n° 13-224-12)\u003c\/li\u003e\n\u003cli\u003eCrimped hanging brackets for \u003cstrong\u003eceiling mounting\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHeat Exchanger\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHighly efficient \u003cstrong\u003ealuminum counter-flow heat exchanger\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eProvides up to \u003cstrong\u003e90% heat recovery\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003elifetime use\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMotors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e2x Low-energy, high-efficiency backward-curved EC motors\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003eheat and speed protection\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCan be installed \u003cstrong\u003evertically or horizontally\u003c\/strong\u003e (except CARMA 9048 and 9070)\u003c\/li\u003e\n\u003cli\u003eSuitable for \u003cstrong\u003eindoor or outdoor\u003c\/strong\u003e installation\u003c\/li\u003e\n\u003cli\u003eFits in \u003cstrong\u003efalse ceilings\u003c\/strong\u003e (models 9008 to 9035)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15mm BSP metal condensate drain point\u003c\/strong\u003e for easy drainage (requires waterless trap connection)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Ductwork\u003c\/h3\u003e\n\u003cp\u003eFor superior strength, we recommend using \u003cstrong\u003eMetal Spiral Ducting and Fittings\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e9035\u003c\/td\u003e\n\u003ctd\u003e2625\u003c\/td\u003e\n\u003ctd\u003e1515\u003c\/td\u003e\n\u003ctd\u003e805\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003eComplete your installation with a range of compatible accessories:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDucting systems\u003c\/li\u003e\n\u003cli\u003eSensors\u003c\/li\u003e\n\u003cli\u003eIn-line silencers\u003c\/li\u003e\n\u003cli\u003eFloor, wall, and ceiling inlet\/outlet diffusers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGuarantee\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eImportant Information\u003c\/h3\u003e\n\u003cp\u003eThese units are \u003cstrong\u003ebuilt to order\u003c\/strong\u003e. For lead times and further inquiries, please contact our sales team at  \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736215249222,"sku":"KCDF026658","price":14992.15,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/zehnder_csy_caladair_carma_4.jpg?v=1732551508"},{"product_id":"freetime-smart-zone-800","title":"Zehnder Caladair Freetime First Eco 800","description":"\u003ch3\u003e\u003cstrong\u003eZehnder Caladair Freetime First Eco 800\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eCaladair FREETIME 800 First Eco\u003c\/strong\u003e - \u003cstrong\u003eCDF024149\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eZehnder Caladair Freetime First Eco 800\u003c\/strong\u003e is a \u003cstrong\u003ecompact, high-performance commercial heat recovery unit\u003c\/strong\u003e designed for superior energy efficiency and air quality control. With \u003cstrong\u003ezoning options, heating \u0026amp; cooling accessories, and advanced filtration\u003c\/strong\u003e, this unit is ideal for various commercial and industrial applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Zoning Options \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis unit can be upgraded with \u003cstrong\u003eoptional electric duct dampers\u003c\/strong\u003e, which can be controlled by:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePIR Sensor\u003c\/strong\u003e – Detects occupancy and increases airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO₂ Sensor\u003c\/strong\u003e – Detects high CO₂ levels and adjusts airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall Switch\u003c\/strong\u003e – Manually increases airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Sensor\u003c\/strong\u003e – Adjusts airflow when lights are switched on.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMS (Building Management System)\u003c\/strong\u003e – Controls zoned areas and unit settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDampers\u003c\/strong\u003e – Configurable to \u003cstrong\u003evarious airflow rates\u003c\/strong\u003e when open or closed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor \u003cstrong\u003ecustomization and additional zoning options\u003c\/strong\u003e, contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHeating \u0026amp; Cooling Accessories \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOptional heating and cooling accessories include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost buildup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Increases room temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Heater\u003c\/strong\u003e – Can be used as a \u003cstrong\u003epre-heater or post-heater\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControllability \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003eDigital Control Panel\u003c\/strong\u003e is available for independent operation without a \u003cstrong\u003eBMS system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eLCD Controller Functions:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWeekly timer\u003c\/li\u003e\n\u003cli\u003eHoliday timer\u003c\/li\u003e\n\u003cli\u003eSummer by-pass \/ Night-time cooling\u003c\/li\u003e\n\u003cli\u003eFault finding\u003c\/li\u003e\n\u003cli\u003eSpeed parameters\u003c\/li\u003e\n\u003cli\u003eFilter indicator\u003c\/li\u003e\n\u003cli\u003eFire alarm integration\u003c\/li\u003e\n\u003cli\u003eTemperature sensors\u003c\/li\u003e\n\u003cli\u003eIntegration via \u003cstrong\u003eModbus, Bacnet, or Web\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFiltration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x F7\u003c\/strong\u003e large-capacity pollen intake filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x G4\u003c\/strong\u003e extract filter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Construction\u003c\/strong\u003e: \u003cstrong\u003eAirtight 10-gauge galvanized steel double-skin panels\u003c\/strong\u003e with \u003cstrong\u003e25mm high-density mineral wool insulation\u003c\/strong\u003e in accordance with \u003cstrong\u003eEN1886\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Face\u003c\/strong\u003e: Pre-lacquered with a protective film in \u003cstrong\u003eRAL 7035\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections\u003c\/strong\u003e: Circular branch connections with rubber seals. Airtight construction to \u003cstrong\u003eATEC CSTB n° 13-224-12\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: \u003cstrong\u003eCrimped hanging brackets\u003c\/strong\u003e for ceiling mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHeat Exchanger \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly efficient aluminium counter-flow heat exchanger\u003c\/strong\u003e that provides up to \u003cstrong\u003e90% heat recovery\u003c\/strong\u003e, designed for lifetime use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMotors \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2x low-energy, high-efficiency backward curved EC motors\u003c\/strong\u003e with heat and speed protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe unit is \u003cstrong\u003ehorizontally mounted\u003c\/strong\u003e on the ceiling or floor with \u003cstrong\u003eadjustable hanging brackets\u003c\/strong\u003e. Ensure the structure can support the unit’s weight.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate Drain\u003c\/strong\u003e: \u003cstrong\u003e15mm BSP metal pipe\u003c\/strong\u003e provided on the side of the unit, which should be connected to a drain via a \u003cstrong\u003ewaterless trap\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDimensions \u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFreetime 800\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1080\u003c\/td\u003e\n\u003ctd\u003e700\u003c\/td\u003e\n\u003ctd\u003e1090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation of Ductwork \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWe recommend using \u003cstrong\u003eMetal Spiral Ducting\u003c\/strong\u003e and \u003cstrong\u003efittings\u003c\/strong\u003e for superior strength. To ensure optimal airtightness and durability, use \u003cstrong\u003eself-sealing fittings\u003c\/strong\u003e or a combination of \u003cstrong\u003eDucting Sealant\u003c\/strong\u003e and \u003cstrong\u003eAluminium Duct Sealing Tape\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA full range of \u003cstrong\u003econtrols, sensors, in-line silencers, floor\/wall\/ceiling inlets, and outlet diffusers\u003c\/strong\u003e are available to complete the installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGuarantee \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e for peace of mind.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlease Note\u003c\/strong\u003e – These units are \u003cstrong\u003ebuilt to order\u003c\/strong\u003e. For lead times on the \u003cstrong\u003eCaladair Freetime Commercial Units\u003c\/strong\u003e, please contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736215347526,"sku":"KCDF024149","price":5465.02,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/freetime_5.png?v=1732551537"},{"product_id":"freetime-smart-zone-1500","title":"Zehnder Caladair Freetime First Eco 1500","description":"\u003ch3\u003e\u003cstrong\u003eZehnder Caladair Freetime First Eco 1500\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eCaladair FREETIME 1500 First Eco\u003c\/strong\u003e - \u003cstrong\u003eCDF024150\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eZehnder Caladair Freetime First Eco 1500\u003c\/strong\u003e is a high-performance, energy-efficient heat recovery unit, specifically designed for commercial applications. It offers flexible zoning options and can be integrated into various heating and cooling solutions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Zoning Options \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOptional extras are available for controlling zones via \u003cstrong\u003eCaladair Commercial Units\u003c\/strong\u003e. Zones are controlled with electric duct dampers and can be operated through several solutions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePIR Sensor\u003c\/strong\u003e – Detects occupation and increases airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO₂ Sensor\u003c\/strong\u003e – Detects high CO₂ levels and increases airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall Switch\u003c\/strong\u003e – Increases airflow when the switch is pressed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight\u003c\/strong\u003e – Increases airflow when the light is switched on.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMS (Building Management System)\u003c\/strong\u003e – Increases or decreases airflow in zoned areas via the BMS system.\u003c\/li\u003e\n\u003cli\u003eDampers can be set to various airflow rates when open or closed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more information on how to add these extras to your system, please contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHeating \u0026amp; Cooling Accessories \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAvailable accessories for heating and cooling include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost from affecting the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Increases room temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Heater\u003c\/strong\u003e – Can be used as a pre-heater or post-heater.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControllability \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003eDigital Control Panel\u003c\/strong\u003e is available if not connecting to a \u003cstrong\u003eBMS system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eLCD Controller Functions:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWeekly timer\u003c\/li\u003e\n\u003cli\u003eHoliday timer\u003c\/li\u003e\n\u003cli\u003eSummer by-pass \/ Night-time cooling\u003c\/li\u003e\n\u003cli\u003eFault finding\u003c\/li\u003e\n\u003cli\u003eSpeed parameters\u003c\/li\u003e\n\u003cli\u003eFilter indicator\u003c\/li\u003e\n\u003cli\u003eFire alarm integration\u003c\/li\u003e\n\u003cli\u003eTemperature sensors\u003c\/li\u003e\n\u003cli\u003eIntegration via \u003cstrong\u003eModbus\u003c\/strong\u003e, \u003cstrong\u003eBacnet\u003c\/strong\u003e, or \u003cstrong\u003eWeb\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFiltration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x F7\u003c\/strong\u003e large capacity pollen intake filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x G4\u003c\/strong\u003e extract filter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Construction\u003c\/strong\u003e: Airtight \u003cstrong\u003e10-gauge galvanized steel double-skin panels\u003c\/strong\u003e with \u003cstrong\u003e25mm high-density mineral wool insulation\u003c\/strong\u003e in accordance with \u003cstrong\u003eEN1886\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Face\u003c\/strong\u003e: Pre-lacquered with a protective film in \u003cstrong\u003eRAL 7035\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections\u003c\/strong\u003e: Circular branch connections with rubber seals. Airtight construction to \u003cstrong\u003eATEC CSTB n° 13-224-12\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Crimped hanging brackets for ceiling mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHeat Exchanger \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly efficient aluminium counter-flow heat exchanger\u003c\/strong\u003e that provides up to \u003cstrong\u003e90% heat recovery\u003c\/strong\u003e, designed for lifetime use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMotors \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2x low energy, high-efficiency backward curved EC motors\u003c\/strong\u003e with heat and speed protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe unit is \u003cstrong\u003ehorizontally mounted\u003c\/strong\u003e on the ceiling or floor and comes with adjustable hanging brackets to secure to the frame or concrete ceiling. Ensure the structure can support the unit's weight.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate Drain\u003c\/strong\u003e: \u003cstrong\u003e15mm BSP metal pipe\u003c\/strong\u003e provided on the side of the unit for connection to a drain via a waterless trap.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDimensions \u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFreetime 1500\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003ctd\u003e1140\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation of Ductwork \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWe recommend \u003cstrong\u003eMetal Spiral ducting\u003c\/strong\u003e and fittings for superior strength. To ensure optimal airtightness and durability, use \u003cstrong\u003eself-sealing fittings\u003c\/strong\u003e or a combination of \u003cstrong\u003eDucting Sealant\u003c\/strong\u003e and \u003cstrong\u003eAluminium Duct Sealing Tape\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIn addition to a choice of compatible ducting systems, a full range of \u003cstrong\u003econtrols\u003c\/strong\u003e, \u003cstrong\u003esensors\u003c\/strong\u003e, \u003cstrong\u003ein-line silencers\u003c\/strong\u003e, and \u003cstrong\u003efloor\/wall\/ceiling inlet and outlet diffusers\u003c\/strong\u003e are available to complete your installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGuarantee \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e for peace of mind.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease Note\u003c\/strong\u003e – These units are built to order. For lead times on the \u003cstrong\u003eCaladair Freetime Commercial Units\u003c\/strong\u003e, please contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736215675206,"sku":"KCDF024150","price":7548.79,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/freetime_1.png?v=1732551549"},{"product_id":"freetime-smart-zone-2000","title":"Zehnder Caladair Freetime First Eco 2000","description":"\u003ch3\u003e\u003cstrong\u003eZehnder Caladair Freetime First Eco 2000\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eCaladair FREETIME 2000 First Eco\u003c\/strong\u003e - \u003cstrong\u003eCDF024151\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eZehnder Caladair Freetime First Eco 2000\u003c\/strong\u003e is a high-performance, energy-efficient \u003cstrong\u003ecommercial heat recovery unit\u003c\/strong\u003e designed for superior air management. It offers \u003cstrong\u003eflexible zoning options\u003c\/strong\u003e and integrates seamlessly into \u003cstrong\u003eheating and cooling systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Zoning Options \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOptional extras allow for zoning control via \u003cstrong\u003eelectric duct dampers\u003c\/strong\u003e, which can be managed using:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePIR Sensor\u003c\/strong\u003e – Detects occupation and increases airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO₂ Sensor\u003c\/strong\u003e – Detects high CO₂ levels and increases airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall Switch\u003c\/strong\u003e – Increases airflow when pressed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Sensor\u003c\/strong\u003e – Increases airflow when lights are switched on.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMS (Building Management System)\u003c\/strong\u003e – Adjusts airflow in zoned areas via the BMS system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDampers\u003c\/strong\u003e can be set to various airflow rates when open or closed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more details on \u003cstrong\u003eadding zoning extras\u003c\/strong\u003e, please contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHeating \u0026amp; Cooling Accessories \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAvailable accessories include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost buildup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Increases room temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Heater\u003c\/strong\u003e – Can be used as a pre-heater or post-heater.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControllability \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003eDigital Control Panel\u003c\/strong\u003e is available if not connected to a \u003cstrong\u003eBMS system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eLCD Controller Functions:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWeekly timer\u003c\/li\u003e\n\u003cli\u003eHoliday timer\u003c\/li\u003e\n\u003cli\u003eSummer by-pass \/ Night-time cooling\u003c\/li\u003e\n\u003cli\u003eFault finding\u003c\/li\u003e\n\u003cli\u003eSpeed parameters\u003c\/li\u003e\n\u003cli\u003eFilter indicator\u003c\/li\u003e\n\u003cli\u003eFire alarm integration\u003c\/li\u003e\n\u003cli\u003eTemperature sensors\u003c\/li\u003e\n\u003cli\u003eIntegration via \u003cstrong\u003eModbus, Bacnet, or Web\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFiltration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x F7\u003c\/strong\u003e large-capacity pollen intake filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x G4\u003c\/strong\u003e extract filter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Construction\u003c\/strong\u003e: \u003cstrong\u003eAirtight 10-gauge galvanized steel double-skin panels\u003c\/strong\u003e with \u003cstrong\u003e25mm high-density mineral wool insulation\u003c\/strong\u003e in accordance with \u003cstrong\u003eEN1886\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Face\u003c\/strong\u003e: Pre-lacquered with a protective film in \u003cstrong\u003eRAL 7035\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections\u003c\/strong\u003e: Circular branch connections with rubber seals. Airtight construction to \u003cstrong\u003eATEC CSTB n° 13-224-12\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: \u003cstrong\u003eCrimped hanging brackets\u003c\/strong\u003e for ceiling mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHeat Exchanger \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly efficient aluminium counter-flow heat exchanger\u003c\/strong\u003e that provides up to \u003cstrong\u003e90% heat recovery\u003c\/strong\u003e, designed for lifetime use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMotors \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2x low-energy, high-efficiency backward curved EC motors\u003c\/strong\u003e with heat and speed protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe unit is \u003cstrong\u003ehorizontally mounted\u003c\/strong\u003e on the ceiling or floor with \u003cstrong\u003eadjustable hanging brackets\u003c\/strong\u003e. Ensure the structure can support the unit’s weight.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate Drain\u003c\/strong\u003e: \u003cstrong\u003e15mm BSP metal pipe\u003c\/strong\u003e provided on the side of the unit, which should be connected to a drain via a \u003cstrong\u003ewaterless trap\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDimensions \u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFreetime 2000\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e830\u003c\/td\u003e\n\u003ctd\u003e1220\u003c\/td\u003e\n\u003ctd\u003e1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation of Ductwork \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWe recommend using \u003cstrong\u003eMetal Spiral Ducting\u003c\/strong\u003e and \u003cstrong\u003efittings\u003c\/strong\u003e for superior strength. To ensure optimal airtightness and durability, use \u003cstrong\u003eself-sealing fittings\u003c\/strong\u003e or a combination of \u003cstrong\u003eDucting Sealant\u003c\/strong\u003e and \u003cstrong\u003eAluminium Duct Sealing Tape\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA full range of \u003cstrong\u003econtrols, sensors, in-line silencers, floor\/wall\/ceiling inlets, and outlet diffusers\u003c\/strong\u003e are available to complete the installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGuarantee \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e for peace of mind.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlease Note\u003c\/strong\u003e – These units are \u003cstrong\u003ebuilt to order\u003c\/strong\u003e. For lead times on the \u003cstrong\u003eCaladair Freetime Commercial Units\u003c\/strong\u003e, please contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736215707974,"sku":"KCDF024151","price":8558.42,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/freetime_2.png?v=1732551542"},{"product_id":"freetime-smart-zone-2700","title":"Zehnder Caladair Freetime First Eco 2700","description":"\u003ch3\u003e\u003cstrong\u003eZehnder Caladair Freetime First Eco 2700\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eCaladair FREETIME 2700 First Eco\u003c\/strong\u003e - \u003cstrong\u003eCAL23\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eZehnder Caladair Freetime First Eco 2700\u003c\/strong\u003e is a \u003cstrong\u003ehigh-performance, energy-efficient commercial heat recovery unit\u003c\/strong\u003e designed for optimal air management in industrial and tertiary sector applications. It features \u003cstrong\u003ezoning control\u003c\/strong\u003e, integration with \u003cstrong\u003eheating \u0026amp; cooling systems\u003c\/strong\u003e, and \u003cstrong\u003eadvanced filtration\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Zoning Options \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis unit supports \u003cstrong\u003eelectric duct dampers\u003c\/strong\u003e, controlled via:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePIR Sensor\u003c\/strong\u003e – Detects occupancy and increases airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO₂ Sensor\u003c\/strong\u003e – Detects high CO₂ levels and adjusts airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall Switch\u003c\/strong\u003e – Increases airflow when pressed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Sensor\u003c\/strong\u003e – Increases airflow when lights are switched on.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMS (Building Management System)\u003c\/strong\u003e – Adjusts airflow in zoned areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDampers\u003c\/strong\u003e can be set to \u003cstrong\u003evarious airflow rates\u003c\/strong\u003e when open or closed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor further \u003cstrong\u003ecustomization and additional zoning options\u003c\/strong\u003e, please contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHeating \u0026amp; Cooling Accessories \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAvailable accessories include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost buildup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Increases room temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Heater\u003c\/strong\u003e – Can be used as a \u003cstrong\u003epre-heater or post-heater\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControllability \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003eDigital Control Panel\u003c\/strong\u003e is available if not connected to a \u003cstrong\u003eBMS system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eLCD Controller Functions:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWeekly timer\u003c\/li\u003e\n\u003cli\u003eHoliday timer\u003c\/li\u003e\n\u003cli\u003eSummer by-pass \/ Night-time cooling\u003c\/li\u003e\n\u003cli\u003eFault finding\u003c\/li\u003e\n\u003cli\u003eSpeed parameters\u003c\/li\u003e\n\u003cli\u003eFilter indicator\u003c\/li\u003e\n\u003cli\u003eFire alarm integration\u003c\/li\u003e\n\u003cli\u003eTemperature sensors\u003c\/li\u003e\n\u003cli\u003eIntegration via \u003cstrong\u003eModbus, Bacnet, or Web\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFiltration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x F7\u003c\/strong\u003e large-capacity pollen intake filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x G4\u003c\/strong\u003e extract filter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Construction\u003c\/strong\u003e: \u003cstrong\u003eAirtight 10-gauge galvanized steel double-skin panels\u003c\/strong\u003e with \u003cstrong\u003e25mm high-density mineral wool insulation\u003c\/strong\u003e in accordance with \u003cstrong\u003eEN1886\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Face\u003c\/strong\u003e: Pre-lacquered with a protective film in \u003cstrong\u003eRAL 7035\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections\u003c\/strong\u003e: Circular branch connections with rubber seals. Airtight construction to \u003cstrong\u003eATEC CSTB n° 13-224-12\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: \u003cstrong\u003eCrimped hanging brackets\u003c\/strong\u003e for ceiling mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHeat Exchanger \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly efficient aluminium counter-flow heat exchanger\u003c\/strong\u003e that provides up to \u003cstrong\u003e90% heat recovery\u003c\/strong\u003e, designed for lifetime use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMotors \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2x low-energy, high-efficiency backward curved EC motors\u003c\/strong\u003e with heat and speed protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe unit is \u003cstrong\u003ehorizontally mounted\u003c\/strong\u003e on the ceiling or floor with \u003cstrong\u003eadjustable hanging brackets\u003c\/strong\u003e. Ensure the structure can support the unit’s weight.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate Drain\u003c\/strong\u003e: \u003cstrong\u003e15mm BSP metal pipe\u003c\/strong\u003e provided on the side of the unit, which should be connected to a drain via a \u003cstrong\u003ewaterless trap\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDimensions \u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFreetime 2700\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e920\u003c\/td\u003e\n\u003ctd\u003e1420\u003c\/td\u003e\n\u003ctd\u003e1610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation of Ductwork \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWe recommend using \u003cstrong\u003eMetal Spiral Ducting\u003c\/strong\u003e and \u003cstrong\u003efittings\u003c\/strong\u003e for superior strength. To ensure optimal airtightness and durability, use \u003cstrong\u003eself-sealing fittings\u003c\/strong\u003e or a combination of \u003cstrong\u003eDucting Sealant\u003c\/strong\u003e and \u003cstrong\u003eAluminium Duct Sealing Tape\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA full range of \u003cstrong\u003econtrols, sensors, in-line silencers, floor\/wall\/ceiling inlets, and outlet diffusers\u003c\/strong\u003e are available to complete the installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGuarantee \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e for peace of mind.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlease Note\u003c\/strong\u003e – These units are \u003cstrong\u003ebuilt to order\u003c\/strong\u003e. For lead times on the \u003cstrong\u003eCaladair Freetime Commercial Units\u003c\/strong\u003e, please contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736215740742,"sku":"KCDF024152","price":9959.3,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/freetime_3.png?v=1732551554"},{"product_id":"freetime-smart-zone-3500","title":"Zehnder Caladair Freetime First Eco 3500","description":"\u003ch3\u003e\u003cstrong\u003eZehnder Caladair Freetime First Eco 3500\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eCaladair FREETIME 3500 First Eco\u003c\/strong\u003e - \u003cstrong\u003eCAL24\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eZehnder Caladair Freetime First Eco 3500\u003c\/strong\u003e is a \u003cstrong\u003ehigh-performance, energy-efficient commercial heat recovery unit\u003c\/strong\u003e designed for industrial and commercial applications. Featuring \u003cstrong\u003eadvanced zoning controls\u003c\/strong\u003e, \u003cstrong\u003eheating \u0026amp; cooling compatibility\u003c\/strong\u003e, and \u003cstrong\u003ehigh-efficiency filtration\u003c\/strong\u003e, this unit ensures superior indoor air quality and optimal performance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Zoning Options \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOptional extras allow zone control via \u003cstrong\u003eelectric duct dampers\u003c\/strong\u003e, operated through:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePIR Sensor\u003c\/strong\u003e – Detects occupancy and increases airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO₂ Sensor\u003c\/strong\u003e – Detects high CO₂ levels and adjusts airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall Switch\u003c\/strong\u003e – Manually increases airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Sensor\u003c\/strong\u003e – Adjusts airflow when lights are switched on.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMS (Building Management System)\u003c\/strong\u003e – Controls zoned areas and unit settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDampers\u003c\/strong\u003e – Configurable to \u003cstrong\u003evarious airflow rates\u003c\/strong\u003e when open or closed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor \u003cstrong\u003ecustomization and additional zoning options\u003c\/strong\u003e, contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHeating \u0026amp; Cooling Accessories \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAvailable accessories include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost buildup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Increases room temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Heater\u003c\/strong\u003e – Can be used as a \u003cstrong\u003epre-heater or post-heater\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControllability \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003eDigital Control Panel\u003c\/strong\u003e is available for use when not connected to a \u003cstrong\u003eBMS system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eLCD Controller Functions:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWeekly timer\u003c\/li\u003e\n\u003cli\u003eHoliday timer\u003c\/li\u003e\n\u003cli\u003eSummer by-pass \/ Night-time cooling\u003c\/li\u003e\n\u003cli\u003eFault finding\u003c\/li\u003e\n\u003cli\u003eSpeed parameters\u003c\/li\u003e\n\u003cli\u003eFilter indicator\u003c\/li\u003e\n\u003cli\u003eFire alarm integration\u003c\/li\u003e\n\u003cli\u003eTemperature sensors\u003c\/li\u003e\n\u003cli\u003eIntegration via \u003cstrong\u003eModbus, Bacnet, or Web\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFiltration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x F7\u003c\/strong\u003e large-capacity pollen intake filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x G4\u003c\/strong\u003e extract filter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Construction\u003c\/strong\u003e: \u003cstrong\u003eAirtight 10-gauge galvanized steel double-skin panels\u003c\/strong\u003e with \u003cstrong\u003e25mm high-density mineral wool insulation\u003c\/strong\u003e in accordance with \u003cstrong\u003eEN1886\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Face\u003c\/strong\u003e: Pre-lacquered with a protective film in \u003cstrong\u003eRAL 7035\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections\u003c\/strong\u003e: Circular branch connections with rubber seals. Airtight construction to \u003cstrong\u003eATEC CSTB n° 13-224-12\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: \u003cstrong\u003eCrimped hanging brackets\u003c\/strong\u003e for ceiling mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHeat Exchanger \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly efficient aluminium counter-flow heat exchanger\u003c\/strong\u003e that provides up to \u003cstrong\u003e90% heat recovery\u003c\/strong\u003e, designed for lifetime use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMotors \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2x low-energy, high-efficiency backward curved EC motors\u003c\/strong\u003e with heat and speed protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe unit is \u003cstrong\u003ehorizontally mounted\u003c\/strong\u003e on the ceiling or floor with \u003cstrong\u003eadjustable hanging brackets\u003c\/strong\u003e. Ensure the structure can support the unit’s weight.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate Drain\u003c\/strong\u003e: \u003cstrong\u003e15mm BSP metal pipe\u003c\/strong\u003e provided on the side of the unit, which should be connected to a drain via a \u003cstrong\u003ewaterless trap\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDimensions \u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFreetime 3500\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1085\u003c\/td\u003e\n\u003ctd\u003e1420\u003c\/td\u003e\n\u003ctd\u003e1730\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation of Ductwork \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWe recommend using \u003cstrong\u003eMetal Spiral Ducting\u003c\/strong\u003e and \u003cstrong\u003efittings\u003c\/strong\u003e for superior strength. To ensure optimal airtightness and durability, use \u003cstrong\u003eself-sealing fittings\u003c\/strong\u003e or a combination of \u003cstrong\u003eDucting Sealant\u003c\/strong\u003e and \u003cstrong\u003eAluminium Duct Sealing Tape\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA full range of \u003cstrong\u003econtrols, sensors, in-line silencers, floor\/wall\/ceiling inlets, and outlet diffusers\u003c\/strong\u003e are available to complete the installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGuarantee \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e for peace of mind.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlease Note\u003c\/strong\u003e – These units are \u003cstrong\u003ebuilt to order\u003c\/strong\u003e. For lead times on the \u003cstrong\u003eCaladair Freetime Commercial Units\u003c\/strong\u003e, please contact our sales team at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736215773510,"sku":"KCDF024153","price":10669.66,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/freetime_4.png?v=1732551566"},{"product_id":"silvertop-smart-eco-06","title":"Zehnder Caladair Silvertop 06 First Eco Commercial MVHR Unit","description":"\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003e\u003cstrong\u003eZehnder Caladair Silvertop 06 First Eco Commercial MVHR Unit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.caladair.com\/en\/details\/produit\/silvertoptm-double-flux-contre-courant\"\u003eCaladair SILVERTOP 06 First Eco\u003c\/a\u003e - CAL06\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eAirflow zoning options available\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eHighly efficient counter-flow plate energy exchanger\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eLow-energy EC motors\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e with heat \u0026amp; speed protection\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eCompact design \u0026amp; small footprint\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eIndoor installation\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e90%+ heat recovery efficiency\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eEasy, quick, and airtight installation\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eAdditional Zoning Options\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eOptional extras for \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003ezone control\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e via Caladair Commercial Units:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003ePIR sensor\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e – Detects occupation \u0026amp; increases airflow\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eCO₂ sensor\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e – Detects high CO₂ levels \u0026amp; increases airflow\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eWall switch\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e – Manually increase airflow\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eLight sensor\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e – Activates airflow when lights are on\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eBMS integration\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e – Control zones \u0026amp; unit via BMS system\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e Dampers can be set to \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003evarious airflow rates\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e when open or closed.  \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eFor more info, contact us at 028 2827 5150.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHeating \u0026amp; Cooling Accessories\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eElectric Preheater\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e – Prevents frost buildup\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e – Increases room temperature\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eWater Heater\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e – Can be used as a pre or post heater\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eEnergy Exchanger\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eHighly efficient aluminum counter-flow plate exchanger\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eDesigned for lifetime use\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e90%+ heat recovery efficiency\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eMotors\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eTwo low-energy backward curved EC motors\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eIntegrated heat \u0026amp; speed protection\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eIndoor installation\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eCompact design \u0026amp; small footprint\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eTop connections via double-lip circular connectors\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e (except size 52)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eEasy, quick, and airtight installation\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e (no adapters required)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eLength (mm)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eWidth (mm)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eHeight (mm)\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSilvertop 06\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1105\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e570\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1040\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan\u003eDuctwork Insulation Recommendations\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor best performance, we recommend using \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eMetal Spiral Ducting and Fittings\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e. To ensure airtightness and durability:\u003c\/span\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eApply duct sealant\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e to male fittings.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePush components together.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSeal the joint with aluminum duct sealing tape.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eDucting in cold areas (e.g. loft spaces) must be insulated\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e with at least \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e25mm thick material\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e with \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003ethermal conductivity ≤ 0.04W\/(m·K)\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e to prevent condensation.  \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eIntake and exhaust ducts should be insulated\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e even if there is no loft space.  \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eBubble wrap insulation is not compliant with building regulations.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAccessories\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eComplete your ventilation system with a range of \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003econtrols, sensors, silencers, and valves\/diffusers\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eGuarantee\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eImportant Information\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThese units are \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003ebuilt to order\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e. For lead times and further inquiries, please contact our sales team at  \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e028 2827 5150\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736216166726,"sku":"KCDF028656","price":5063.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/silvertop.png?v=1732551577"},{"product_id":"silvertop-smart-zone-08","title":"Zehnder Caladair Silvertop 08 First Eco Commercial MVHR Unit","description":"\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003e\u003cstrong\u003eZehnder Caladair Silvertop 08 First Eco Commercial MVHR Unit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.caladair.com\/en\/details\/produit\/silvertoptm-double-flux-contre-courant\"\u003eCaladair SILVERTOP 08 First Eco\u003c\/a\u003e - CAL07\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eAirflow zoning options available\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eHighly efficient counter-flow plate energy exchanger\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eLow-energy EC motors\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e with heat \u0026amp; speed protection\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eCompact design \u0026amp; small footprint\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eIndoor installation\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e90%+ heat recovery efficiency\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eEasy, quick, and airtight installation\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eAdditional Zoning Options\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eOptional extras for \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003ezone control\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e via Caladair Commercial Units:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003ePIR sensor\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e – Detects occupation \u0026amp; increases airflow\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eCO₂ sensor\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e – Detects high CO₂ levels \u0026amp; increases airflow\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eWall switch\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e – Manually increase airflow\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eLight sensor\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e – Activates airflow when lights are on\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eBMS integration\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e – Control zones \u0026amp; unit via BMS system\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e Dampers can be set to \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003evarious airflow rates\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e when open or closed.  \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eFor more info, contact us at 028 2827 5150.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHeating \u0026amp; Cooling Accessories\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eElectric Preheater\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e – Prevents frost buildup\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e – Increases room temperature\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eWater Heater\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e – Can be used as a pre or post heater\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eEnergy Exchanger\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eHighly efficient aluminum counter-flow plate exchanger\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eDesigned for lifetime use\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e90%+ heat recovery efficiency\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eMotors\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eTwo low-energy backward curved EC motors\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eIntegrated heat \u0026amp; speed protection\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eIndoor installation\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eCompact design \u0026amp; small footprint\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eTop connections via double-lip circular connectors\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e (except size 52)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eEasy, quick, and airtight installation\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e (no adapters required)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eLength (mm)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eWidth (mm)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eHeight (mm)\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSilvertop 08\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1265\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e700\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1150\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan\u003eDuctwork Insulation Recommendations\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor best performance, we recommend using \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eMetal Spiral Ducting and Fittings\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e. To ensure airtightness and durability:\u003c\/span\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eApply duct sealant\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e to male fittings.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePush components together.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSeal the joint with aluminum duct sealing tape.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eDucting in cold areas (e.g. loft spaces) must be insulated\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e with at least \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e25mm thick material\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e with \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003ethermal conductivity ≤ 0.04W\/(m·K)\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e to prevent condensation.  \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eIntake and exhaust ducts should be insulated\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e even if there is no loft space.  \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eBubble wrap insulation is not compliant with building regulations.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAccessories\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eComplete your ventilation system with a range of \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003econtrols, sensors, silencers, and valves\/diffusers\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eGuarantee\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eImportant Information\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThese units are \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003ebuilt to order\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e. For lead times and further inquiries, please contact our sales team at  \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e028 2827 5150\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736216199494,"sku":"KCDF028675","price":6268.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/silvertop_1.png?v=1732551589"},{"product_id":"caladair-silvertop-smart-zone-15","title":"Zehnder Caladair Silvertop 15 First Eco Commercial MVHR Unit","description":"\u003cp\u003e\u003cstrong\u003eZehnder Caladair Silvertop 15 First Eco Commercial MVHR Unit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.caladair.com\/en\/details\/produit\/silvertoptm-double-flux-contre-courant\"\u003eCaladair SILVERTOP 15 First Eco\u003c\/a\u003e - CAL08\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003eAirflow zoning options available\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eHighly efficient counter-flow plate energy exchanger\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eLow-energy EC motors\u003c\/strong\u003e with heat \u0026amp; speed protection\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eCompact design \u0026amp; small footprint\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eIndoor installation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003e90%+ heat recovery efficiency\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eEasy, quick, and airtight installation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Zoning Options\u003c\/h3\u003e\n\u003cp\u003eOptional extras for \u003cstrong\u003ezone control\u003c\/strong\u003e via Caladair Commercial Units:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003ePIR sensor\u003c\/strong\u003e – Detects occupation \u0026amp; increases airflow\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eCO₂ sensor\u003c\/strong\u003e – Detects high CO₂ levels \u0026amp; increases airflow\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eWall switch\u003c\/strong\u003e – Manually increase airflow\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eLight sensor\u003c\/strong\u003e – Activates airflow when lights are on\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eBMS integration\u003c\/strong\u003e – Control zones \u0026amp; unit via BMS system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e Dampers can be set to \u003cstrong\u003evarious airflow rates\u003c\/strong\u003e when open or closed.  \u003cstrong\u003eFor more info, contact us at 028 2827 5150.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eHeating \u0026amp; Cooling Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost buildup\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Increases room temperature\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eWater Heater\u003c\/strong\u003e – Can be used as a pre or post heater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnergy Exchanger\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly efficient aluminum counter-flow plate exchanger\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigned for lifetime use\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90%+ heat recovery efficiency\u003c\/strong\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMotors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo low-energy backward curved EC motors\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated heat \u0026amp; speed protection\u003c\/strong\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003eIndoor installation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCompact design \u0026amp; small footprint\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop connections via double-lip circular connectors\u003c\/strong\u003e (except size 52)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy, quick, and airtight installation\u003c\/strong\u003e (no adapters required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilvertop 15\u003c\/td\u003e\n\u003ctd\u003e1590\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003ctd\u003e1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDuctwork Insulation Recommendations\u003c\/h3\u003e\n\u003cp\u003eFor best performance, we recommend using \u003cstrong\u003eMetal Spiral Ducting and Fittings\u003c\/strong\u003e. To ensure airtightness and durability:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eApply duct sealant\u003c\/strong\u003e to male fittings.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePush components together.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSeal the joint with aluminum duct sealing tape.\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e \u003cstrong\u003eDucting in cold areas (e.g. loft spaces) must be insulated\u003c\/strong\u003e with at least \u003cstrong\u003e25mm thick material\u003c\/strong\u003e with \u003cstrong\u003ethermal conductivity ≤ 0.04W\/(m·K)\u003c\/strong\u003e to prevent condensation.  \u003cstrong\u003eIntake and exhaust ducts should be insulated\u003c\/strong\u003e even if there is no loft space.  \u003cstrong\u003eBubble wrap insulation is not compliant with building regulations.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003eComplete your ventilation system with a range of \u003cstrong\u003econtrols, sensors, silencers, and valves\/diffusers\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGuarantee\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eImportant Information\u003c\/h3\u003e\n\u003cp\u003eThese units are \u003cstrong\u003ebuilt to order\u003c\/strong\u003e. For lead times and further inquiries, please contact our sales team at  \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736216265030,"sku":"KCDF028694","price":7538.17,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/silvertop_2.png?v=1732551602"},{"product_id":"silvertop-smart-zone-23","title":"Zehnder Caladair Silvertop 23 First Eco Commercial MVHR Unit","description":"\u003cp\u003e\u003cstrong\u003eZehnder Caladair Silvertop 23 First Eco Commercial MVHR Unit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.caladair.com\/en\/details\/produit\/silvertoptm-double-flux-contre-courant\"\u003eCaladair SILVERTOP 23 First Eco\u003c\/a\u003e - CAL09\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003eAirflow zoning options available\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eHighly efficient counter-flow plate energy exchanger\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eLow-energy EC motors\u003c\/strong\u003e with heat \u0026amp; speed protection\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eCompact design \u0026amp; small footprint\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eIndoor installation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003e90%+ heat recovery efficiency\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eEasy, quick, and airtight installation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Zoning Options\u003c\/h3\u003e\n\u003cp\u003eOptional extras for \u003cstrong\u003ezone control\u003c\/strong\u003e via Caladair Commercial Units:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003ePIR sensor\u003c\/strong\u003e – Detects occupation \u0026amp; increases airflow\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eCO₂ sensor\u003c\/strong\u003e – Detects high CO₂ levels \u0026amp; increases airflow\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eWall switch\u003c\/strong\u003e – Manually increase airflow\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eLight sensor\u003c\/strong\u003e – Activates airflow when lights are on\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eBMS integration\u003c\/strong\u003e – Control zones \u0026amp; unit via BMS system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e Dampers can be set to \u003cstrong\u003evarious airflow rates\u003c\/strong\u003e when open or closed.  \u003cstrong\u003eFor more info, contact us at 028 2827 5150.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eHeating \u0026amp; Cooling Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost buildup\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Increases room temperature\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eWater Heater\u003c\/strong\u003e – Can be used as a pre or post heater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnergy Exchanger\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly efficient aluminum counter-flow plate exchanger\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigned for lifetime use\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90%+ heat recovery efficiency\u003c\/strong\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMotors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo low-energy backward curved EC motors\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated heat \u0026amp; speed protection\u003c\/strong\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003eIndoor installation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCompact design \u0026amp; small footprint\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop connections via double-lip circular connectors\u003c\/strong\u003e (except size 52)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy, quick, and airtight installation\u003c\/strong\u003e (no adapters required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilvertop 23\u003c\/td\u003e\n\u003ctd\u003e1735\u003c\/td\u003e\n\u003ctd\u003e1065\u003c\/td\u003e\n\u003ctd\u003e1340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDuctwork Insulation Recommendations\u003c\/h3\u003e\n\u003cp\u003eFor best performance, we recommend using \u003cstrong\u003eMetal Spiral Ducting and Fittings\u003c\/strong\u003e. To ensure airtightness and durability:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eApply duct sealant\u003c\/strong\u003e to male fittings.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePush components together.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSeal the joint with aluminum duct sealing tape.\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e \u003cstrong\u003eDucting in cold areas (e.g. loft spaces) must be insulated\u003c\/strong\u003e with at least \u003cstrong\u003e25mm thick material\u003c\/strong\u003e with \u003cstrong\u003ethermal conductivity ≤ 0.04W\/(m·K)\u003c\/strong\u003e to prevent condensation.  \u003cstrong\u003eIntake and exhaust ducts should be insulated\u003c\/strong\u003e even if there is no loft space.  \u003cstrong\u003eBubble wrap insulation is not compliant with building regulations.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003eComplete your ventilation system with a range of \u003cstrong\u003econtrols, sensors, silencers, and valves\/diffusers\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGuarantee\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eImportant Information\u003c\/h3\u003e\n\u003cp\u003eThese units are \u003cstrong\u003ebuilt to order\u003c\/strong\u003e. For lead times and further inquiries, please contact our sales team at  \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736216297798,"sku":"KCDF028725","price":9962.84,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/silvertop_3.png?v=1732551614"},{"product_id":"caladair-smart-zone-35","title":"Zehnder Caladair Silvertop 35 First Eco Commercial MVHR Unit","description":"\u003cp\u003e\u003cstrong\u003eZehnder Caladair Silvertop 35 First Eco Commercial MVHR Unit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.caladair.com\/en\/details\/produit\/silvertoptm-double-flux-contre-courant\"\u003eCaladair SILVERTOP 35 First Eco\u003c\/a\u003e - CAL10\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003eAirflow zoning options available\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eHighly efficient counter-flow plate energy exchanger\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eLow-energy EC motors\u003c\/strong\u003e with heat \u0026amp; speed protection\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eCompact design \u0026amp; small footprint\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eIndoor installation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003e90%+ heat recovery efficiency\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eEasy, quick, and airtight installation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Zoning Options\u003c\/h3\u003e\n\u003cp\u003eOptional extras for \u003cstrong\u003ezone control\u003c\/strong\u003e via Caladair Commercial Units:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003ePIR sensor\u003c\/strong\u003e – Detects occupation \u0026amp; increases airflow\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eCO₂ sensor\u003c\/strong\u003e – Detects high CO₂ levels \u0026amp; increases airflow\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eWall switch\u003c\/strong\u003e – Manually increase airflow\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eLight sensor\u003c\/strong\u003e – Activates airflow when lights are on\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eBMS integration\u003c\/strong\u003e – Control zones \u0026amp; unit via BMS system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e Dampers can be set to \u003cstrong\u003evarious airflow rates\u003c\/strong\u003e when open or closed.  \u003cstrong\u003eFor more info, contact us at 028 2827 5150.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eHeating \u0026amp; Cooling Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost buildup\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Increases room temperature\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eWater Heater\u003c\/strong\u003e – Can be used as a pre or post heater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnergy Exchanger\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly efficient aluminum counter-flow plate exchanger\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigned for lifetime use\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90%+ heat recovery efficiency\u003c\/strong\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMotors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo low-energy backward curved EC motors\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated heat \u0026amp; speed protection\u003c\/strong\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003eIndoor installation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCompact design \u0026amp; small footprint\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop connections via double-lip circular connectors\u003c\/strong\u003e (except size 52)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy, quick, and airtight installation\u003c\/strong\u003e (no adapters required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eLength (mm)\u003c\/th\u003e\n\u003cth\u003eWidth (mm)\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilvertop 35\u003c\/td\u003e\n\u003ctd\u003e1950\u003c\/td\u003e\n\u003ctd\u003e1210\u003c\/td\u003e\n\u003ctd\u003e1495\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDuctwork Insulation Recommendations\u003c\/h3\u003e\n\u003cp\u003eFor best performance, we recommend using \u003cstrong\u003eMetal Spiral Ducting and Fittings\u003c\/strong\u003e. To ensure airtightness and durability:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eApply duct sealant\u003c\/strong\u003e to male fittings.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePush components together.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSeal the joint with aluminum duct sealing tape.\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e \u003cstrong\u003eDucting in cold areas (e.g. loft spaces) must be insulated\u003c\/strong\u003e with at least \u003cstrong\u003e25mm thick material\u003c\/strong\u003e with \u003cstrong\u003ethermal conductivity ≤ 0.04W\/(m·K)\u003c\/strong\u003e to prevent condensation.  \u003cstrong\u003eIntake and exhaust ducts should be insulated\u003c\/strong\u003e even if there is no loft space.  \u003cstrong\u003eBubble wrap insulation is not compliant with building regulations.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003eComplete your ventilation system with a range of \u003cstrong\u003econtrols, sensors, silencers, and valves\/diffusers\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGuarantee\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003e2-Year Parts Guarantee\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eImportant Information\u003c\/h3\u003e\n\u003cp\u003eThese units are \u003cstrong\u003ebuilt to order\u003c\/strong\u003e. For lead times and further inquiries, please contact our sales team at  \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736216330566,"sku":"KCDF028756","price":13091.76,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/silvertop_4.png?v=1732551561"},{"product_id":"silvertop-smart-zone-52","title":"Zehnder Caladair Silvertop 52 First Eco Commercial MVHR Unit","description":"\u003ch3\u003e\u003cstrong\u003eZehnder Caladair Silvertop 52 First Eco Commercial MVHR Unit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Part Number:\u003c\/strong\u003e CAL11\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e Product Description \u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \u003ca href=\"SILVERTOP%E2%84%A2,%20self-regulating%20energy%20recovery%20unit,%20high%20efficiency%20\u0026gt;90%%20(EN308),%20for%20offices%20and%20industrial%20applications%20in%20ventilation%20and%20energy%20recovery.\"\u003e\u003cstrong\u003eZehnder Caladair Silvertop 52 First Eco\u003c\/strong\u003e\u003c\/a\u003e is a high-performance \u003cstrong\u003eMVHR (Mechanical Ventilation with Heat Recovery) unit\u003c\/strong\u003e designed for commercial use. It provides efficient energy recovery, exceptional air quality, and long-lasting performance.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e Additional Zoning Options\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eOptional extras are available for enhanced control over the zoning of your \u003cstrong\u003eCaladair Commercial Units\u003c\/strong\u003e. Zones can be managed with the following solutions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePIR Sensor\u003c\/strong\u003e – Detects occupancy and increases airflow automatically\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO₂ Sensor\u003c\/strong\u003e – Monitors CO₂ levels and boosts airflow when needed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall Switch\u003c\/strong\u003e – Manually increases airflow with a simple switch press\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Activation\u003c\/strong\u003e – Boosts airflow when the light is turned on\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMS Control\u003c\/strong\u003e – Adjusts airflow and zones via Building Management System (BMS)\u003cbr\u003eThe electric duct dampers are adjustable to provide different airflow rates when open or closed.\u003cbr\u003e \u003cstrong\u003eNeed more details on extras?\u003c\/strong\u003e Contact us at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e for more information!\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003e Heating \u0026amp;  Cooling Options\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eChoose from a range of heating and cooling accessories:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Preheater\u003c\/strong\u003e – Prevents frost damage to the unit \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Post Heater\u003c\/strong\u003e – Increases room temperature \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Heater\u003c\/strong\u003e – Can be used as either a preheater or post heater \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003e Energy Exchanger\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThis unit features a \u003cstrong\u003ehighly efficient counter-flow plate energy exchanger\u003c\/strong\u003e, made of durable aluminum. It offers \u003cstrong\u003e90% or more heat recovery\u003c\/strong\u003e for optimal energy efficiency. \u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e Motors\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEquipped with \u003cstrong\u003e2 x low-energy consumption\u003c\/strong\u003e EC motors for maximum efficiency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackward curved\u003c\/strong\u003e design for improved airflow and energy savings\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003eheat \u0026amp; speed protection\u003c\/strong\u003e for added reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003e Installation\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor Installation\u003c\/strong\u003e: Compact design with small footprint for easy installation in tight spaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop Connections\u003c\/strong\u003e: Double-lip circular connectors (except size 52) for quick, airtight, and cost-efficient setup (no adapters required)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuctwork Recommendation\u003c\/strong\u003e: We suggest using \u003cstrong\u003eMetal Spiral Ducting\u003c\/strong\u003e for superior strength and durability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003e Dimensions\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eLength (mm)\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eWidth (mm)\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eHeight (mm)\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilvertop 52\u003c\/td\u003e\n\u003ctd\u003e2185\u003c\/td\u003e\n\u003ctd\u003e1520\u003c\/td\u003e\n\u003ctd\u003e1625\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003e Accessories\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eWe offer a full range of accessories including compatible \u003cstrong\u003educting systems\u003c\/strong\u003e, \u003cstrong\u003econtrols\u003c\/strong\u003e, \u003cstrong\u003esensors\u003c\/strong\u003e, \u003cstrong\u003ein-line silencers\u003c\/strong\u003e, and \u003cstrong\u003ediffusers\u003c\/strong\u003e (for floor\/wall\/ceiling installations). Perfect for completing your setup!\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e Guarantee\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eEnjoy peace of mind with a \u003cstrong\u003e2-year parts guarantee\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease Note\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThese units are \u003cstrong\u003ebuilt to order\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eFor the lead time on the \u003cstrong\u003eCaladair Neotime Commercial Units\u003c\/strong\u003e, please \u003cstrong\u003econtact our sales team\u003c\/strong\u003e at \u003cstrong\u003e028 2827 5150\u003c\/strong\u003e for more details.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Zehnder Caladair","offers":[{"title":"Default Title","offer_id":53736216363334,"sku":"KCDF028787","price":15749.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/silvertop_5.png?v=1732551572"},{"product_id":"bsk-scholar500-unit","title":"BSK Scholar 500 Classroom Heat Recovery Unit","description":"\u003ch2\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"\u003eBSK Scholar Classroom Heat Recovery Unit\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(31, 201, 49);\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif;\"\u003ePossible 8 Week Lead Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e Scholar 500\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHighly efficient heat recovery unit specially designed for classrooms, meeting rooms and offices with C02 demand control operation.\u003c\/p\u003e\n\u003cp\u003eThese units get rid of dust, pollen, spores and other harmful particles to provide 100% fresh filtered air and can either recover up to 95% of normally wasted heat or provide comfort cooling via the free cooling mode\u003c\/p\u003e\n\u003cp\u003eBPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFully automatic control\u003c\/li\u003e\n\u003cli\u003eInternal Co2 sensors\u003c\/li\u003e\n\u003cli\u003eSuitable for offices with up to 15 staff\u003c\/li\u003e\n\u003cli\u003eAirflow rate 500m3\/h\u003c\/li\u003e\n\u003cli\u003e160m pipe connections\u003c\/li\u003e\n\u003cli\u003eUp to 95% heat recovery efficiency.\u003c\/li\u003e\n\u003cli\u003eFree cooling mode via By-Pass\u003c\/li\u003e\n\u003cli\u003eUnit mounted digital controller\u003c\/li\u003e\n\u003cli\u003eTop or rear external pipe spigots\u003c\/li\u003e\n\u003cli\u003e100% full and filtered modulating summer bypass\u003c\/li\u003e\n\u003cli\u003eInternal attenuating silencer\u003c\/li\u003e\n\u003cli\u003eAir quality pressure sensor\u003c\/li\u003e\n\u003cli\u003eTriple filter design of G4, G5 and F7 pollen filter\u003c\/li\u003e\n\u003cli\u003eDouble walled construction with 25mm sound insulation\u003c\/li\u003e\n\u003cli\u003eAnti draft electronic dampers to prevent draft when off\u003c\/li\u003e\n\u003cli\u003eFilter warning\u003c\/li\u003e\n\u003cli\u003eBMS integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg height=\"332\" width=\"332\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/scholar500control_bd3e8dcd-c879-4324-97b5-1525dd6630b0.jpg?v=1732552989\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eControllability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BSK Scholar has a unit mounted controller with a passcode that will allow the authorised person to adjust all setting including\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAir flow settings\u003c\/li\u003e\n\u003cli\u003etemperature,\u003c\/li\u003e\n\u003cli\u003eCo2 levels\u003c\/li\u003e\n\u003cli\u003eWeekley programme\u003c\/li\u003e\n\u003cli\u003eAuto Mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInternal Co2 Sensors \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAn internal mounted Co2 will boost the units speed when required\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBMS Control\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBMS integration is possible through the Modbus port on top of the unit\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBoost Input\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA boost input is positioned on top of the unit\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"574\" width=\"664\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/Scholar500layout_e2a4dbce-dd81-400c-b5b8-9dc65b772708.png?v=1732552995\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBoth the Scholar 500\/700 can be positioned against an external wall or at an internal wall and ducted to the outside (This method will give a slight decrease in performance due to the longer duct pressure increase, as the units are designed to be used with a short duct run or no ducting.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe casing is double walled 0.7mm galvanised steel filled with 25mm of sound insulation in order to keep the sound and heat insulation at the highest level. The outside as well as the inside surfaces of our devices are painted with electrostatic powder paint and deliver a long life, while providing a stylish and clean appearance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMotors\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eHighly efficient backward curved EC fans for maximum efficiency and performance\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFiltration \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA total of 3 filters are fitted as standard to supply superior filtration\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x G4 filter to exhaust air to outside\u003c\/li\u003e\n\u003cli\u003e1 x G4 pre filter to room air supply\u003c\/li\u003e\n\u003cli\u003e1 x F7 post filter to room air supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSummer By-Pass\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BSK Scholar range of units have a 100% summer by-Pass\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLow Noise Levels \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWith airtight, aerodynamic and sound absorbing construction with perfectly balanced fans the noise levels are ultra quiet\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHeat Exchanger \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Highest performing heat recovery exchanger that can recover up to 95% of otherwise lost heat\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrost Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe unit has a frost protection programme\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSilencer\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BSK Scholar as an internal silencer at the fresh air outlet of our device that allows silent\u003c\/p\u003e\n\u003cp\u003eoperation which provides a quiet working environment for classrooms or offices\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOrientation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOnly one orientation is possible\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eManufactured of powder coated galvanised steel outer cover for durability and an inside EPP lining for quietness and efficiency\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMounting \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe unit is floor mounted\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBSK offer a 2-year Parts warranty\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFurther Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFurther information is available on the Manufactures website \u003ca href=\"https:\/\/www.bskhvac.com.tr\/en\/product-detail\/heat-recovery-units\/scholar-high-efficiency-school-type-hru?kat=commercial-ventilation\"\u003e(Click Here)\u003c\/a\u003e\u003c\/p\u003e","brand":"BSK","offers":[{"title":"Default Title","offer_id":53736316535110,"sku":"Scholar 500","price":2765.76,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/bsk_scholar_2.jpg?v=1732553010"},{"product_id":"mitsubishi-50lgh-rvs-e-with-pvc-core-requires-pz-62-controller","title":"Mitsubishi LGH-50 RVS-E  With PVC core","description":"\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for commercial offices and schools \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePerfect for higher humidity environments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAirflow Rate of 500 m3\/hr \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e200 mm duct diameter \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSide and rear spigot options to external pipes \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUp to 93% heat Recovery rate \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe Mitsubishi LGH-50 RVS-E is a popular commercial heat recovery unit and is suitable for any type of commercial application including shower and changing rooms due to the latest PVC heat exchanger\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eKey features- Mitsubishi Lossnay LGH-50 RVS-E\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAirflow Rate of 500 m3\/hr @ 100Pa\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e200 mm duct diameter \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSide and rear spigot options to external pipes \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUp to 93% heat Recovery rate \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLatest PVC core suitable for wet areas \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ecompliance with Part L\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional Mitsubishi Electric energy saving CO2 sensors \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e100% Summer By-Pass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLightweight structure ideal for easy ceiling installation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional digital Controller\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional F7 filtration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e0-10V input option.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eControllability\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eVolt Free contact\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePCB Dipswitch function\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional Controller\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional 12v signal \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional External sensors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional 0-10v DC Input \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional Wi-Fi Interface \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional M-Net connectivity \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eControl compatibility with Mr Slim and City Multi air conditioning systems for a complete and highly effective system operation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg height=\"330\" width=\"360\" src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXc6DAA41q7TQkDOKowTXlVVJd98gJGsySGd43Yr6SudvNeXcOQMJnElewe2COvWecOHgcxKtqmvEieEjNkSqeJZCSO_BXAHF2cXLyXqMyL5b7LpEY0lfK0dTnuGqgMNoRs5MZXXNfMFqKaeUHMP1Ok?key=JKOIStyKTWAA02DmAwxUVjG6\"\u003e\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWall LCD controller (optional)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe optional wall controller PZ-62DR-EB\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003ewill allow you to\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAdjust Fan Speed in 5% increments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFilter warning \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWeekley Timer \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNighttime Purge\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSummer By-Pass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTemperature \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional Co2 display\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance and Run Time \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect to other Mitsubishi products \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperate Multiple Units (max 15)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg height=\"228\" width=\"624\" src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXfOtBy-AAuqNbkm7jRfv7lRGJ6r1W2m28d91u_HVVaBZl7Y847KGsUn_S9mj6iGpDl4y4lPhz_wvfE6xI4VbfmLtRHobEPWtv5ZPOSRTUPlmbMdPB2xnLcdxr8EcvjHwZwlY_CW545_KXAzvzFY1e0?key=JKOIStyKTWAA02DmAwxUVjG6\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eCo2 Sensors \u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWith the option of an additional CO2 sensor. When connected with the optional Wi-Fi Control Interface, CO2 levels can be viewed in real-time making it ideal for schools, medical facilities and offices.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIt is well known that poor air quality impacts health, wellbeing and concentration levels. In conjunction with the CO2 sensor, the Lossnay LGH-RVX3-E system intuitively adjusts airflow to ensure optimum air quality, no matter how many people are in the room.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTwo types of CO2 sensors are available: wall-mounted and duct-mounted types. Power is supplied to the CO2 sensor from the Lossnay board.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg height=\"345\" width=\"650\" src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXftvg7Q68256oEJ4A-sNQmh5UB2f_ppRdgOu-2PQA9CMOAmNKWsZPdyWULBxrASApyJou6hquH1lFlV5LX4zVSYyVg_xnS21F1QV80-meu-byASlz_jGqIbCX9e-V7R9Ygt_IYzC0GlaRy85Ts-z7o?key=JKOIStyKTWAA02DmAwxUVjG6\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe Mitsubishi LGH units’ range are manufactured of airtight and noise absorbing EPP with a metal outer cover\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg height=\"305\" width=\"624\" src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXcy2k1mZICkuYlBGZZcr8Xmmfi51lFY6wr4huTsl_jb4xPT8W61iK640bNV88yzJURdHhkAr5dh1tIy7NvLGFl9HsP2hsnGqnQEYSyydwqoZzu-qsfw89PbqGlaeVGIYMmJWCFQOdzia2VAv3dPmlQ?key=JKOIStyKTWAA02DmAwxUVjG6\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eMotors\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHigh quality commercial motors with Dual-Barrier coating on the fan prevents dust and grease accumulation, ensuring long-term efficient operation \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFlexible supply and exhaust fan commissioning in 5% increments, offering low running costs and easier\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe default fan speed value (Fan speed 1: 25%, Fan speed 2: 50%, Fan speed 3: 75%, and Fan speed 4: 100%) of both supply air and exhaust air can be adjusted flexibly. Within the range between 25% and 100%, airflow can be adjusted by 5% increments to satisfactorily meet the designed airflow rate.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eDual Barrier Coating\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDual Barrier Coating prevents dust and oil build-up on the interior of the Lossnay unit, helping to keep it clean for optimal performance. A water-repellent effect is achieved by creating a coating film that has nano-sized concave-convex structures formed by silica nanoparticles made of water-repellent fluor resin and micron-sized concave-convex structures formed by combining micronized special-shaped particles (silicate) with the silica nanoparticles. At the same time, the uneven structure forms an air layer that suppresses the adhesion of dust and sand that contain a lot of humidity, reducing the amount of dirt that adheres to the substrate.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eFiltration \u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003e2 x G3 filters are fitted to the unit that are easy to replace \u003c\/span\u003e\u003c\/li\u003e\n\u003cli role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eOptional F7 to air supply\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eSummer By-Pass\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe units have a 100% summer by-Pass \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg height=\"220\" width=\"399\" src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXdb_XPM-2nrSTjUpqvx-O1AexQ3qrsyi0AWlHuqYHH5L5B2K_-Uc7VUUd93b7U8qi0tQmJt40gpSVMW1pIxFwl5QsfVgsrScCOfcyQYkupua6jB_4wW1BJ-ovwuihgj0Z47RCvNRZm3NLW-XErb1A?key=JKOIStyKTWAA02DmAwxUVjG6\" alt=\"A close-up of a black and silver air conditioner\n\nAI-generated content may be incorrect.\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eHeat Exchanger \u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe PVC heat exchange can recover up to 90% of normally wasted heat and can be used in areas of high humidity like showers and changing rooms \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eFrost Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe unit has a frost protection programme \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eOrientation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe unit is available in only one orientation \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe external pipes can be repositioned from the rear to side if required \u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eMounting \u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe units are supplied with ceiling mounting brackets and optional wall mounting brackets are available \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMitsubishi offer a 3-year warranty with this unit \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAccessories \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eRemote controller – PZ-62DR-EB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eStandard Filters – PZ-50RF3-E\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eF7 Filter – PZ-50RFP3-E\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eWall Mounted Co2 Sensor – PZ-70CSW-E\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eDuct Mounted Co2 Sensor – PZ-70CSD-E\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eVertical Mounting Bracket – PZ-1VS-E\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFurther Information\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFurther information is available on the Manufactures website \u003c\/span\u003e\u003ca href=\"https:\/\/les.mitsubishielectric.co.uk\/products\/ventilation\/commercial-ventilation-units\/commercial-lossnay-series\/rvx3\"\u003e\u003cspan\u003e(Click Here)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cspan\u003eTechnical \u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg height=\"247\" width=\"624\" src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXevNg22WblorX4Dh-oWw2Ed4vJPHAWw4JfuYxxZWDwyn87w8pVKyTdKx4m7at8S2Db6Zv35R599qwZYJQN11FaC6hlpbqJJ4hp81MU9hGyrDsC1a9xtrW_0McnRRr5d2xbJ36zikd3a9ByucKIRQxw?key=JKOIStyKTWAA02DmAwxUVjG6\" alt=\"A screenshot of a computer\n\nAI-generated content may be incorrect.\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv align=\"left\" dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"311\"\u003e \u003ccol width=\"101\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eLGH-50RVS-E\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHeat Recovery efficiency %\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e93\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAirflow rate @ 100-Pa m3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e500\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSFP (lowest)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e0.72\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDimensions W x H x D (mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e974-947-465\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWeight Kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e55\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFiltration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e2xG3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePre\/ Post Heater\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ex\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSummer Bypass \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFrost protection \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSound level @3m db.(a)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e18-33\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCeiling \/ Floor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDuctwork Connection Location\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSide\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDuctwork Diameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e200\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCondensate drain\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e3 Years\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCountry of manufacture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHeat exchanger\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCounterflow\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDigital Controller\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOptional\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBoost Switch control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eInteractive App Control \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eInternal Humidity control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eInternal Co2 Sensor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eElectronic Orientation change\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAvailable room sensors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBMS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eKNX\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFireplace mode\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAlarm system integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOptional\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSAP Appendix Q\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePassive House Approved\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cb id=\"docs-internal-guid-4d6b626a-7fff-e12c-e4e7-d41eebbaaf3d\"\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":53736424571206,"sku":"LGH-50RVS-E","price":2016.24,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lgh-50rvs-e.jpg?v=1732555693"},{"product_id":"mitsubishi-lossnay-lgh-15rvx3-e","title":"Mitsubishi Lossnay LGH-15RVX3-E","description":"\u003cp\u003e•    Suitable for commercial offices and schools \u003cbr\u003e•    Airflow Rate of 150 m3\/hr @ 100Pa\u003cbr\u003e•    100 mm duct diameter \u003cbr\u003e•    Side and rear spigot options to external pipes \u003cbr\u003e•    Up to 81% heat Recovery rate \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Mitsubishi LGH-15 RVX3-E is one of the most popular commercial heat recovery units  and are suitable for any type of commercial application including Schools and Offices or any property that do not require extraction from showers or other areas of high humidity   \u003c\/p\u003e\n\u003cp\u003eBPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems,\u003c\/p\u003e\n\u003ch3\u003eKey features- Mitsubishi Lossnay LGH-15 RVX3-E\u003c\/h3\u003e\n\u003cp\u003e•    Airflow Rate of 150 m3\/hr @ 100Pa\u003cbr\u003e•    100 mm duct diameter \u003cbr\u003e•    Side and rear spigot options to external pipes \u003cbr\u003e•    Up to 81% heat Recovery rate \u003cbr\u003e•    Lossnay paper core enables total heat exchange (sensible and latent) \u003cbr\u003e•    compliance with Part L\u003cbr\u003e•    Optional Mitsubishi Electric energy saving CO2 sensors \u003cbr\u003e•    100% Summer By-Pass\u003cbr\u003e•    Lightweight structure ideal for easy ceiling installation\u003cbr\u003e•    Vertical installation available for flexibility of application\u003cbr\u003e•    Optional digital Controller\u003cbr\u003e•    Optional F7 filtration\u003cbr\u003e•    0-10V input option.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eControllability\u003c\/h3\u003e\n\u003cp\u003e•    Volt Free contact\u003cbr\u003e•    PCB Dipswitch function\u003cbr\u003e•    Optional Controller\u003cbr\u003e•    Optional 12v signal \u003cbr\u003e•    Optional External sensors\u003cbr\u003e•    Optional 0-10v DC Input \u003cbr\u003e•    Optional Wi-Fi Interface \u003cbr\u003e•    Optional M-Net connectivity \u003cbr\u003e•    Control compatibility with Mr Slim and City \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaycontrol.png?v=1739274693\"\u003e\u003c\/p\u003e\n\u003ch3\u003eWall LCD controller (optional)\u003c\/h3\u003e\n\u003cp\u003eThe optional wall controller PZ-62DR-EB will allow you to \u003cbr\u003e•    Adjust Fan Speed in 5% increments\u003cbr\u003e•    Automatic control\u003cbr\u003e•    Filter warning \u003cbr\u003e•    Weekley Timer \u003cbr\u003e•    Nighttime Purge\u003cbr\u003e•    Summer By-Pass\u003cbr\u003e•    Temperature \u003cbr\u003e•    Optional Co2 display\u003cbr\u003e•    Maintenance and Run Time \u003cbr\u003e•    Connect to other Mitsubishi products \u003cbr\u003e•    Operate Multiple Units (max 15)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaytimer.png?v=1739274788\"\u003e\u003c\/p\u003e\n\u003ch3\u003eCo2 Sensors\u003c\/h3\u003e\n\u003cp\u003eWith the option of an additional CO2 sensor. When connected with the optional Wi-Fi Control Interface, CO2 levels can be viewed in real-time making it ideal for schools, medical facilities and offices.\u003cbr\u003eIt is well known that poor air quality impacts health, wellbeing and concentration levels. In conjunction with the CO2 sensor, the Lossnay LGH-RVX3-E system intuitively adjusts airflow to ensure optimum air quality, no matter how many people are in the room.\u003cbr\u003eTwo types of CO2 sensors are available: wall-mounted and duct-mounted types. Power is supplied to the CO2 sensor from the Lossnay board.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaysensors.png?v=1739274868\"\u003e\u003c\/p\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cp\u003eThe Mitsubishi LGH units’ range are manufactured of airtight and noise absorbing EPP with a metal outer cover\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaymotors.png?v=1739274952\"\u003e\u003c\/p\u003e\n\u003ch3\u003eMotors\u003c\/h3\u003e\n\u003cp\u003eHigh quality commercial motors with Dual-Barrier coating on the fan prevents dust and grease accumulation, ensuring long-term efficient operation\u003c\/p\u003e\n\u003cp\u003eFlexible supply and exhaust fan commissioning in 5% increments, offering low running costs and easier\u003c\/p\u003e\n\u003cp\u003eThe default fan speed value (Fan speed 1: 25%, Fan speed 2: 50%, Fan speed 3: 75%, and Fan speed 4: 100%) of both supply air and exhaust air can be adjusted flexibly. Within the range between 25% and 100%, airflow can be adjusted by 5% increments to satisfactorily meet the designed airflow rate.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDual Barrier Coating\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDual Barrier Coating prevents dust and oil build-up on the interior of the Lossnay unit, helping to keep it clean for optimal performance. A water-repellent effect is achieved by creating a coating film that has nano-sized concave-convex structures formed by silica nanoparticles made of water-repellent fluor resin and micron-sized concave-convex structures formed by combining micronized special-shaped particles (silicate) with the silica nanoparticles. At the same time, the uneven structure forms an air layer that suppresses the adhesion of dust and sand that contain a lot of humidity, reducing the amount of dirt that adheres to the substrate.\u003c\/p\u003e\n\u003ch3\u003eFiltration\u003c\/h3\u003e\n\u003cp\u003e•    2 x G3 filters are fitted to the unit that are easy to replace \u003cbr\u003e•    Optional F7 to air supply\u003c\/p\u003e\n\u003ch3\u003eSummer By-Pass\u003c\/h3\u003e\n\u003cp\u003eThe units have a 100% summer by-Pass \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnayheatexchange.png?v=1739275095\"\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003eHeat Exchanger\u003c\/h3\u003e\n\u003cp\u003eThe key to Lossnay is the unique heat transfer core. Through the Lossnay Core, up to 88%* of the energy in the stale exhaust air is recovered and transferred to pre-warm (or cool) incoming fresh, filtered air.\u003c\/p\u003e\n\u003cp\u003eFor example, in winter a building that has an inside temperature of 20°C and 4°C air outside, the incoming fresh air can be warmed to over 18°C by transferring through a Lossnay Ventilation System and benefitting from the efficient energy transfer process. The building’s air conditioning systems no longer have to work as hard to maintain desired indoor air temperatures.\u003c\/p\u003e\n\u003cp\u003eLossnay LGH-RVX3-E models are equipped with chemically treated paper core to recover sensible and latent heat from the outgoing stale air to pre-warm (or pre-cool) incoming fresh air to achieve higher levels of heat recovery, resulting in both cost and energy savings\u003c\/p\u003e\n\u003cp\u003eThe paper core is Not Suitable for extracting from areas of High Humidity (showers rooms etc)\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003eFrost Protection\u003c\/h3\u003e\n\u003cp\u003eThe unit has a frost protection programme \u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003e\u003cspan style=\"font-size: 10.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-color-alt: windowtext; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnayheatexchangeunit.png?v=1739275187\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eOrientation\u003c\/h3\u003e\n\u003cp\u003eThe unit is available in only one orientation \u003cbr\u003eThe external pipes can be repositioned from the rear to side if required \u003c\/p\u003e\n\u003ch3\u003eMounting\u003c\/h3\u003e\n\u003cp\u003eThe units are supplied with ceiling mounting brackets and optional wall mounting brackets are available\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eMitsubishi offer a 3-year warranty with this unit\u003c\/p\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e•    Remote controller – PZ-62DR-EB\u003cbr\u003e•    Standard Filters – PZ-80RF3-E\u003cbr\u003e•    F7 Filter – PZ-80RFP3-E\u003cbr\u003e•    Wall Mounted Co2 Sensor – PZ-70CSW-E\u003cbr\u003e•    Duct Mounted Co2 Sensor – PZ-70CSD-E\u003cbr\u003e•    Vertical Mounting Bracket – PZ-2VS-E\u003c\/p\u003e\n\u003ch3\u003eFurther Information\u003c\/h3\u003e\n\u003cp\u003eFurther information is available on the \u003ca href=\"https:\/\/les.mitsubishielectric.co.uk\/products\/ventilation\/commercial-ventilation-units\/commercial-lossnay-series\/rvx3\"\u003eManufactures website\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":53736425881926,"sku":"LGH15RVX3-E","price":780.71,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/rvx3-e-commercial-lossnay-ventilation.jpg?v=1732555767"},{"product_id":"mitsubishi-lgh160rvx3-e","title":"Mitsubishi LGH160RVX3-E","description":"\u003cp\u003e•    Suitable for commercial offices and schools \u003cbr\u003e•    Airflow Rate of 1600 m3\/hr @ 100Pa\u003cbr\u003e•    4 x 250 mm duct diameter \u003cbr\u003e•    Side and rear spigot options to external pipes \u003cbr\u003e•    Up to 80% heat Recovery rate \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Mitsubishi LGH-160 RVX3-E are suitable for any type of commercial application including Schools and Offices or any property that do not require extraction from showers or other areas of high humidity\u003c\/p\u003e\n\u003cp\u003ePlease note the depth of this unit and due to 4 x spigots you may require additional transition pieces to connect to ductwork \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eBPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems,\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 14.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003eKey features- Mitsubishi Lossnay LGH-160 RVX3-E\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca name=\"_Hlk174603338\"\u003e\u003c\/a\u003e\u003ca name=\"_Hlk175747586\"\u003e\u003c\/a\u003e\u003cspan style=\"mso-bookmark: _Hlk174603338;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003eAirflow Rate of 1600 m3\/hr @ 100Pa\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"mso-bookmark: _Hlk175747586;\"\u003e\u003cspan style=\"mso-bookmark: _Hlk174603338;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003e4 x 250 mm duct diameter \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"mso-bookmark: _Hlk175747586;\"\u003e\u003cspan style=\"mso-bookmark: _Hlk174603338;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003eSide and rear spigot options to external pipes \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"mso-bookmark: _Hlk175747586;\"\u003e\u003cspan style=\"mso-bookmark: _Hlk174603338;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003eUp to 80% heat Recovery rate \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"mso-bookmark: _Hlk174603338;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003eLossnay paper core enables total heat exchange (sensible and latent) \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"mso-bookmark: _Hlk174603338;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003ecompliance with Part L\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"mso-bookmark: _Hlk174603338;\"\u003e\u003ca name=\"_Hlk175739077\"\u003e\u003c\/a\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003eOptional Mitsubishi Electric energy saving CO2 sensors \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"mso-bookmark: _Hlk174603338;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003e100% Summer By-Pass\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"mso-bookmark: _Hlk174603338;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003eLightweight structure ideal for easy ceiling installation\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"mso-bookmark: _Hlk174603338;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003eVertical installation available for flexibility of application\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"mso-bookmark: _Hlk174603338;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003eOptional digital Controller\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"mso-bookmark: _Hlk174603338;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003eOptional F7 filtration\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"mso-bookmark: _Hlk174603338;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003e0-10V input option.\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan style=\"font-size: 14.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoListParagraphCxSpFirst\" style=\"text-indent: -18.0pt; mso-list: l0 level1 lfo1;\"\u003e\n\u003ca name=\"_Hlk174603338\"\u003e\u003c\/a\u003e\u003ca name=\"_Hlk175747586\"\u003e\u003c\/a\u003e\u003cspan style=\"mso-bookmark: _Hlk174603338;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; line-height: 107%; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eControllability\u003c\/h3\u003e\n\u003cp\u003e•    Volt Free contact\u003cbr\u003e•    PCB Dipswitch function\u003cbr\u003e•    Optional Controller\u003cbr\u003e•    Optional 12v signal \u003cbr\u003e•    Optional External sensors\u003cbr\u003e•    Optional 0-10v DC Input \u003cbr\u003e•    Optional Wi-Fi Interface \u003cbr\u003e•    Optional M-Net connectivity \u003cbr\u003e•    Control compatibility with Mr Slim and City Multi air conditioning systems for a complete and highly effective system operation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaycontrol.png?v=1739274693\"\u003e\u003c\/p\u003e\n\u003ch3\u003eWall LCD controller (optional)\u003c\/h3\u003e\n\u003cp\u003eThe optional wall controller PZ-62DR-EB will allow you to \u003cbr\u003e•    Adjust Fan Speed in 5% increments\u003cbr\u003e•    Automatic control\u003cbr\u003e•    Filter warning \u003cbr\u003e•    Weekley Timer \u003cbr\u003e•    Nighttime Purge\u003cbr\u003e•    Summer By-Pass\u003cbr\u003e•    Temperature \u003cbr\u003e•    Optional Co2 display\u003cbr\u003e•    Maintenance and Run Time \u003cbr\u003e•    Connect to other Mitsubishi products \u003cbr\u003e•    Operate Multiple Units (max 15)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaytimer.png?v=1739274788\"\u003e\u003c\/p\u003e\n\u003ch3\u003eCo2 Sensors\u003c\/h3\u003e\n\u003cp\u003eWith the option of an additional CO2 sensor. When connected with the optional Wi-Fi Control Interface, CO2 levels can be viewed in real-time making it ideal for schools, medical facilities and offices.\u003cbr\u003eIt is well known that poor air quality impacts health, wellbeing and concentration levels. In conjunction with the CO2 sensor, the Lossnay LGH-RVX3-E system intuitively adjusts airflow to ensure optimum air quality, no matter how many people are in the room.\u003cbr\u003eTwo types of CO2 sensors are available: wall-mounted and duct-mounted types. Power is supplied to the CO2 sensor from the Lossnay board.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaysensors.png?v=1739274868\"\u003e\u003c\/p\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cp\u003eThe Mitsubishi LGH units’ range are manufactured of airtight and noise absorbing EPP with a metal outer cover\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaymotors.png?v=1739274952\"\u003e\u003c\/p\u003e\n\u003ch3\u003eMotors\u003c\/h3\u003e\n\u003cp\u003eHigh quality commercial motors with Dual-Barrier coating on the fan prevents dust and grease accumulation, ensuring long-term efficient operation\u003c\/p\u003e\n\u003cp\u003eFlexible supply and exhaust fan commissioning in 5% increments, offering low running costs and easier\u003c\/p\u003e\n\u003cp\u003eThe default fan speed value (Fan speed 1: 25%, Fan speed 2: 50%, Fan speed 3: 75%, and Fan speed 4: 100%) of both supply air and exhaust air can be adjusted flexibly. Within the range between 25% and 100%, airflow can be adjusted by 5% increments to satisfactorily meet the designed airflow rate.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDual Barrier Coating\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDual Barrier Coating prevents dust and oil build-up on the interior of the Lossnay unit, helping to keep it clean for optimal performance. A water-repellent effect is achieved by creating a coating film that has nano-sized concave-convex structures formed by silica nanoparticles made of water-repellent fluor resin and micron-sized concave-convex structures formed by combining micronized special-shaped particles (silicate) with the silica nanoparticles. At the same time, the uneven structure forms an air layer that suppresses the adhesion of dust and sand that contain a lot of humidity, reducing the amount of dirt that adheres to the substrate.\u003c\/p\u003e\n\u003ch3\u003eFiltration\u003c\/h3\u003e\n\u003cp\u003e•    2 x G3 filters are fitted to the unit that are easy to replace \u003cbr\u003e•    Optional F7 to air supply\u003c\/p\u003e\n\u003ch3\u003eSummer By-Pass\u003c\/h3\u003e\n\u003cp\u003eThe units have a 100% summer by-Pass \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnayheatexchange.png?v=1739275095\"\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003eHeat Exchanger\u003c\/h3\u003e\n\u003cp\u003eThe key to Lossnay is the unique heat transfer core. Through the Lossnay Core, up to 88%* of the energy in the stale exhaust air is recovered and transferred to pre-warm (or cool) incoming fresh, filtered air.\u003c\/p\u003e\n\u003cp\u003eFor example, in winter a building that has an inside temperature of 20°C and 4°C air outside, the incoming fresh air can be warmed to over 18°C by transferring through a Lossnay Ventilation System and benefitting from the efficient energy transfer process. The building’s air conditioning systems no longer have to work as hard to maintain desired indoor air temperatures.\u003c\/p\u003e\n\u003cp\u003eLossnay LGH-RVX3-E models are equipped with chemically treated paper core to recover sensible and latent heat from the outgoing stale air to pre-warm (or pre-cool) incoming fresh air to achieve higher levels of heat recovery, resulting in both cost and energy savings\u003c\/p\u003e\n\u003cp\u003eThe paper core is Not Suitable for extracting from areas of High Humidity (showers rooms etc)\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003eFrost Protection\u003c\/h3\u003e\n\u003cp\u003eThe unit has a frost protection programme \u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003e\u003cspan style=\"font-size: 10.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-color-alt: windowtext; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnayheatexchangeunit.png?v=1739275187\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eOrientation\u003c\/h3\u003e\n\u003cp\u003eThe unit is available in only one orientation \u003cbr\u003eThe external pipes can be repositioned from the rear to side if required \u003c\/p\u003e\n\u003ch3\u003eMounting\u003c\/h3\u003e\n\u003cp\u003eThe units are supplied with ceiling mounting brackets and optional wall mounting brackets are available\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eMitsubishi offer a 3-year warranty with this unit\u003c\/p\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e•    Remote controller – PZ-62DR-EB\u003cbr\u003e•    Standard Filters – PZ-80RF3-E\u003cbr\u003e•    F7 Filter – PZ-80RFP3-E\u003cbr\u003e•    Wall Mounted Co2 Sensor – PZ-70CSW-E\u003cbr\u003e•    Duct Mounted Co2 Sensor – PZ-70CSD-E\u003cbr\u003e•    Vertical Mounting Bracket – PZ-2VS-E\u003c\/p\u003e\n\u003ch3\u003eFurther Information\u003c\/h3\u003e\n\u003cp\u003eFurther information is available on the \u003ca href=\"https:\/\/les.mitsubishielectric.co.uk\/products\/ventilation\/commercial-ventilation-units\/commercial-lossnay-series\/rvx3\"\u003eManufactures website\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":53736425914694,"sku":"LGH160RVX3-E","price":4249.34,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/rvx3-100-160.jpg?v=1732555789"},{"product_id":"mitsubishi-lossnay-lgh-25rvx3-e","title":"Mitsubishi Lossnay LGH-25RVX3-E","description":"\u003cp\u003e•    Suitable for commercial offices and schools \u003cbr\u003e•    Airflow Rate of 250 m3\/hr @ 100Pa\u003cbr\u003e•    150 mm duct diameter \u003cbr\u003e•    Side and rear spigot options to external pipes \u003cbr\u003e•    Up to 88% heat Recovery rate \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Mitsubishi LGH-25 RVX3-E is one of the most popular commercial heat recovery units and are suitable for any type of commercial application including Schools and Offices or any property that do not require extraction from showers or other areas of high humidity\u003c\/p\u003e\n\u003cp\u003eBPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems,\u003c\/p\u003e\n\u003ch3\u003eKey features- Mitsubishi Lossnay LGH-25 RVX3-E\u003c\/h3\u003e\n\u003cp\u003e•    Airflow Rate of 250 m3\/hr @ 100Pa\u003cbr\u003e•    150 mm duct diameter \u003cbr\u003e•    Side and rear spigot options to external pipes \u003cbr\u003e•    Up to 88% heat Recovery rate \u003cbr\u003e•    Lossnay paper core enables total heat exchange (sensible and latent) \u003cbr\u003e•    compliance with Part L\u003cbr\u003e•    Optional Mitsubishi Electric energy saving CO2 sensors \u003cbr\u003e•    100% Summer By-Pass\u003cbr\u003e•    Lightweight structure ideal for easy ceiling installation\u003cbr\u003e•    Vertical installation available for flexibility of application\u003cbr\u003e•    Optional digital Controller\u003cbr\u003e•    Optional F7 filtration\u003cbr\u003e•    0-10V input option.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eControllability\u003c\/h3\u003e\n\u003cp\u003e•    Volt Free contact\u003cbr\u003e•    PCB Dipswitch function\u003cbr\u003e•    Optional Controller\u003cbr\u003e•    Optional 12v signal \u003cbr\u003e•    Optional External sensors\u003cbr\u003e•    Optional 0-10v DC Input \u003cbr\u003e•    Optional Wi-Fi Interface \u003cbr\u003e•    Optional M-Net connectivity \u003cbr\u003e•    Control compatibility with Mr Slim and City Multi air conditioning systems for a complete and highly effective system operation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaycontrol.png?v=1739274693\"\u003e\u003c\/p\u003e\n\u003ch3\u003eWall LCD controller (optional)\u003c\/h3\u003e\n\u003cp\u003eThe optional wall controller PZ-62DR-EB will allow you to \u003cbr\u003e•    Adjust Fan Speed in 5% increments\u003cbr\u003e•    Automatic control\u003cbr\u003e•    Filter warning \u003cbr\u003e•    Weekley Timer \u003cbr\u003e•    Nighttime Purge\u003cbr\u003e•    Summer By-Pass\u003cbr\u003e•    Temperature \u003cbr\u003e•    Optional Co2 display\u003cbr\u003e•    Maintenance and Run Time \u003cbr\u003e•    Connect to other Mitsubishi products \u003cbr\u003e•    Operate Multiple Units (max 15)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaytimer.png?v=1739274788\"\u003e\u003c\/p\u003e\n\u003ch3\u003eCo2 Sensors\u003c\/h3\u003e\n\u003cp\u003eWith the option of an additional CO2 sensor. When connected with the optional Wi-Fi Control Interface, CO2 levels can be viewed in real-time making it ideal for schools, medical facilities and offices.\u003cbr\u003eIt is well known that poor air quality impacts health, wellbeing and concentration levels. In conjunction with the CO2 sensor, the Lossnay LGH-RVX3-E system intuitively adjusts airflow to ensure optimum air quality, no matter how many people are in the room.\u003cbr\u003eTwo types of CO2 sensors are available: wall-mounted and duct-mounted types. Power is supplied to the CO2 sensor from the Lossnay board.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaysensors.png?v=1739274868\"\u003e\u003c\/p\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cp\u003eThe Mitsubishi LGH units’ range are manufactured of airtight and noise absorbing EPP with a metal outer cover\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaymotors.png?v=1739274952\"\u003e\u003c\/p\u003e\n\u003ch3\u003eMotors\u003c\/h3\u003e\n\u003cp\u003eHigh quality commercial motors with Dual-Barrier coating on the fan prevents dust and grease accumulation, ensuring long-term efficient operation\u003c\/p\u003e\n\u003cp\u003eFlexible supply and exhaust fan commissioning in 5% increments, offering low running costs and easier\u003c\/p\u003e\n\u003cp\u003eThe default fan speed value (Fan speed 1: 25%, Fan speed 2: 50%, Fan speed 3: 75%, and Fan speed 4: 100%) of both supply air and exhaust air can be adjusted flexibly. Within the range between 25% and 100%, airflow can be adjusted by 5% increments to satisfactorily meet the designed airflow rate.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDual Barrier Coating\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDual Barrier Coating prevents dust and oil build-up on the interior of the Lossnay unit, helping to keep it clean for optimal performance. A water-repellent effect is achieved by creating a coating film that has nano-sized concave-convex structures formed by silica nanoparticles made of water-repellent fluor resin and micron-sized concave-convex structures formed by combining micronized special-shaped particles (silicate) with the silica nanoparticles. At the same time, the uneven structure forms an air layer that suppresses the adhesion of dust and sand that contain a lot of humidity, reducing the amount of dirt that adheres to the substrate.\u003c\/p\u003e\n\u003ch3\u003eFiltration\u003c\/h3\u003e\n\u003cp\u003e•    2 x G3 filters are fitted to the unit that are easy to replace \u003cbr\u003e•    Optional F7 to air supply\u003c\/p\u003e\n\u003ch3\u003eSummer By-Pass\u003c\/h3\u003e\n\u003cp\u003eThe units have a 100% summer by-Pass \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnayheatexchange.png?v=1739275095\"\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003eHeat Exchanger\u003c\/h3\u003e\n\u003cp\u003eThe key to Lossnay is the unique heat transfer core. Through the Lossnay Core, up to 88%* of the energy in the stale exhaust air is recovered and transferred to pre-warm (or cool) incoming fresh, filtered air.\u003c\/p\u003e\n\u003cp\u003eFor example, in winter a building that has an inside temperature of 20°C and 4°C air outside, the incoming fresh air can be warmed to over 18°C by transferring through a Lossnay Ventilation System and benefitting from the efficient energy transfer process. The building’s air conditioning systems no longer have to work as hard to maintain desired indoor air temperatures.\u003c\/p\u003e\n\u003cp\u003eLossnay LGH-RVX3-E models are equipped with chemically treated paper core to recover sensible and latent heat from the outgoing stale air to pre-warm (or pre-cool) incoming fresh air to achieve higher levels of heat recovery, resulting in both cost and energy savings\u003c\/p\u003e\n\u003cp\u003eThe paper core is Not Suitable for extracting from areas of High Humidity (showers rooms etc)\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003eFrost Protection\u003c\/h3\u003e\n\u003cp\u003eThe unit has a frost protection programme \u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003e\u003cspan style=\"font-size: 10.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-color-alt: windowtext; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnayheatexchangeunit.png?v=1739275187\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eOrientation\u003c\/h3\u003e\n\u003cp\u003eThe unit is available in only one orientation \u003cbr\u003eThe external pipes can be repositioned from the rear to side if required \u003c\/p\u003e\n\u003ch3\u003eMounting\u003c\/h3\u003e\n\u003cp\u003eThe units are supplied with ceiling mounting brackets and optional wall mounting brackets are available\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eMitsubishi offer a 3-year warranty with this unit\u003c\/p\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e•    Remote controller – PZ-62DR-EB\u003cbr\u003e•    Standard Filters – PZ-80RF3-E\u003cbr\u003e•    F7 Filter – PZ-80RFP3-E\u003cbr\u003e•    Wall Mounted Co2 Sensor – PZ-70CSW-E\u003cbr\u003e•    Duct Mounted Co2 Sensor – PZ-70CSD-E\u003cbr\u003e•    Vertical Mounting Bracket – PZ-2VS-E\u003c\/p\u003e\n\u003ch3\u003eFurther Information\u003c\/h3\u003e\n\u003cp\u003eFurther information is available on the \u003ca href=\"https:\/\/les.mitsubishielectric.co.uk\/products\/ventilation\/commercial-ventilation-units\/commercial-lossnay-series\/rvx3\"\u003eManufactures website\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":53736451670342,"sku":"LGH25RVX3-E","price":920.21,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/rvx3-e-commercial-lossnay-ventilation_1.jpg?v=1732556244"},{"product_id":"mitsubishi-lossnay-lgh-35rvx3-e","title":"Mitsubishi Lossnay LGH-35RVX3-E","description":"\u003cp\u003e•    Suitable for commercial offices and schools \u003cbr\u003e•    Airflow Rate of 350 m3\/hr @ 100Pa\u003cbr\u003e•    150 mm duct diameter \u003cbr\u003e•    Side and rear spigot options to external pipes \u003cbr\u003e•    Up to 82% heat Recovery rate \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Mitsubishi LGH-35 RVX3-E is one of the most popular commercial heat recovery units and are suitable for any type of commercial application including Schools and Offices or any property that do not require extraction from showers or other areas of high humidity  \u003c\/p\u003e\n\u003cp\u003eBPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems,\u003c\/p\u003e\n\u003ch3\u003eKey features- Mitsubishi Lossnay LGH-35 RVX3-E\u003c\/h3\u003e\n\u003cp\u003e•    Airflow Rate of 350 m3\/hr @ 100Pa\u003cbr\u003e•    150 mm duct diameter \u003cbr\u003e•    Side and rear spigot options to external pipes \u003cbr\u003e•    Up to 82% heat Recovery rate \u003cbr\u003e•    Lossnay paper core enables total heat exchange (sensible and latent) \u003cbr\u003e•    compliance with Part L\u003cbr\u003e•    Optional Mitsubishi Electric energy saving CO2 sensors \u003cbr\u003e•    100% Summer By-Pass\u003cbr\u003e•    Lightweight structure ideal for easy ceiling installation\u003cbr\u003e•    Vertical installation available for flexibility of application\u003cbr\u003e•    Optional digital Controller\u003cbr\u003e•    Optional F7 filtration\u003cbr\u003e•    0-10V input option.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eControllability\u003c\/h3\u003e\n\u003cp\u003e•    Volt Free contact\u003cbr\u003e•    PCB Dipswitch function\u003cbr\u003e•    Optional Controller\u003cbr\u003e•    Optional 12v signal \u003cbr\u003e•    Optional External sensors\u003cbr\u003e•    Optional 0-10v DC Input \u003cbr\u003e•    Optional Wi-Fi Interface \u003cbr\u003e•    Optional M-Net connectivity \u003cbr\u003e•    Control compatibility with Mr Slim and City Multi air conditioning systems for a complete and highly effective system operation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaycontrol.png?v=1739274693\"\u003e\u003c\/p\u003e\n\u003ch3\u003eWall LCD controller (optional)\u003c\/h3\u003e\n\u003cp\u003eThe optional wall controller PZ-62DR-EB will allow you to \u003cbr\u003e•    Adjust Fan Speed in 5% increments\u003cbr\u003e•    Automatic control\u003cbr\u003e•    Filter warning \u003cbr\u003e•    Weekley Timer \u003cbr\u003e•    Nighttime Purge\u003cbr\u003e•    Summer By-Pass\u003cbr\u003e•    Temperature \u003cbr\u003e•    Optional Co2 display\u003cbr\u003e•    Maintenance and Run Time \u003cbr\u003e•    Connect to other Mitsubishi products \u003cbr\u003e•    Operate Multiple Units (max 15)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaytimer.png?v=1739274788\"\u003e\u003c\/p\u003e\n\u003ch3\u003eCo2 Sensors\u003c\/h3\u003e\n\u003cp\u003eWith the option of an additional CO2 sensor. When connected with the optional Wi-Fi Control Interface, CO2 levels can be viewed in real-time making it ideal for schools, medical facilities and offices.\u003cbr\u003eIt is well known that poor air quality impacts health, wellbeing and concentration levels. In conjunction with the CO2 sensor, the Lossnay LGH-RVX3-E system intuitively adjusts airflow to ensure optimum air quality, no matter how many people are in the room.\u003cbr\u003eTwo types of CO2 sensors are available: wall-mounted and duct-mounted types. Power is supplied to the CO2 sensor from the Lossnay board.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaysensors.png?v=1739274868\"\u003e\u003c\/p\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cp\u003eThe Mitsubishi LGH units’ range are manufactured of airtight and noise absorbing EPP with a metal outer cover\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaymotors.png?v=1739274952\"\u003e\u003c\/p\u003e\n\u003ch3\u003eMotors\u003c\/h3\u003e\n\u003cp\u003eHigh quality commercial motors with Dual-Barrier coating on the fan prevents dust and grease accumulation, ensuring long-term efficient operation\u003c\/p\u003e\n\u003cp\u003eFlexible supply and exhaust fan commissioning in 5% increments, offering low running costs and easier\u003c\/p\u003e\n\u003cp\u003eThe default fan speed value (Fan speed 1: 25%, Fan speed 2: 50%, Fan speed 3: 75%, and Fan speed 4: 100%) of both supply air and exhaust air can be adjusted flexibly. Within the range between 25% and 100%, airflow can be adjusted by 5% increments to satisfactorily meet the designed airflow rate.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDual Barrier Coating\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDual Barrier Coating prevents dust and oil build-up on the interior of the Lossnay unit, helping to keep it clean for optimal performance. A water-repellent effect is achieved by creating a coating film that has nano-sized concave-convex structures formed by silica nanoparticles made of water-repellent fluor resin and micron-sized concave-convex structures formed by combining micronized special-shaped particles (silicate) with the silica nanoparticles. At the same time, the uneven structure forms an air layer that suppresses the adhesion of dust and sand that contain a lot of humidity, reducing the amount of dirt that adheres to the substrate.\u003c\/p\u003e\n\u003ch3\u003eFiltration\u003c\/h3\u003e\n\u003cp\u003e•    2 x G3 filters are fitted to the unit that are easy to replace \u003cbr\u003e•    Optional F7 to air supply\u003c\/p\u003e\n\u003ch3\u003eSummer By-Pass\u003c\/h3\u003e\n\u003cp\u003eThe units have a 100% summer by-Pass \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnayheatexchange.png?v=1739275095\"\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003eHeat Exchanger\u003c\/h3\u003e\n\u003cp\u003eThe key to Lossnay is the unique heat transfer core. Through the Lossnay Core, up to 88%* of the energy in the stale exhaust air is recovered and transferred to pre-warm (or cool) incoming fresh, filtered air.\u003c\/p\u003e\n\u003cp\u003eFor example, in winter a building that has an inside temperature of 20°C and 4°C air outside, the incoming fresh air can be warmed to over 18°C by transferring through a Lossnay Ventilation System and benefitting from the efficient energy transfer process. The building’s air conditioning systems no longer have to work as hard to maintain desired indoor air temperatures.\u003c\/p\u003e\n\u003cp\u003eLossnay LGH-RVX3-E models are equipped with chemically treated paper core to recover sensible and latent heat from the outgoing stale air to pre-warm (or pre-cool) incoming fresh air to achieve higher levels of heat recovery, resulting in both cost and energy savings\u003c\/p\u003e\n\u003cp\u003eThe paper core is Not Suitable for extracting from areas of High Humidity (showers rooms etc)\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003eFrost Protection\u003c\/h3\u003e\n\u003cp\u003eThe unit has a frost protection programme \u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003e\u003cspan style=\"font-size: 10.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-color-alt: windowtext; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnayheatexchangeunit.png?v=1739275187\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eOrientation\u003c\/h3\u003e\n\u003cp\u003eThe unit is available in only one orientation \u003cbr\u003eThe external pipes can be repositioned from the rear to side if required \u003c\/p\u003e\n\u003ch3\u003eMounting\u003c\/h3\u003e\n\u003cp\u003eThe units are supplied with ceiling mounting brackets and optional wall mounting brackets are available\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eMitsubishi offer a 3-year warranty with this unit\u003c\/p\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e•    Remote controller – PZ-62DR-EB\u003cbr\u003e•    Standard Filters – PZ-80RF3-E\u003cbr\u003e•    F7 Filter – PZ-80RFP3-E\u003cbr\u003e•    Wall Mounted Co2 Sensor – PZ-70CSW-E\u003cbr\u003e•    Duct Mounted Co2 Sensor – PZ-70CSD-E\u003cbr\u003e•    Vertical Mounting Bracket – PZ-2VS-E\u003c\/p\u003e\n\u003ch3\u003eFurther Information\u003c\/h3\u003e\n\u003cp\u003eFurther information is available on the \u003ca href=\"https:\/\/les.mitsubishielectric.co.uk\/products\/ventilation\/commercial-ventilation-units\/commercial-lossnay-series\/rvx3\"\u003eManufactures website\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":53736451703110,"sku":"LGH35RVX3-E","price":1206.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/rvx3-e-commercial-lossnay-ventilation_1_1.jpg?v=1732556253"},{"product_id":"mitsubishi-lossnay-lgh-50rvx3-e","title":"Mitsubishi Lossnay LGH-50RVX3-E","description":"\u003cp\u003e•    Suitable for commercial offices and schools \u003cbr\u003e•    Airflow Rate of 500 m3\/hr @ 100Pa\u003cbr\u003e•    200 mm duct diameter \u003cbr\u003e•    Side and rear spigot options to external pipes \u003cbr\u003e•    Up to 75% heat Recovery rate \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Mitsubishi LGH-50 RVX3-E is one of the most popular commercial heat recovery units and are suitable for any type of commercial application including Schools and Offices or any property that do not require extraction from showers or other areas of high humidity  \u003c\/p\u003e\n\u003cp\u003eBPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems,\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 14.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003eKey features- Mitsubishi Lossnay LGH-50 RVX3-E\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e•    Airflow Rate of 500 m3\/hr @ 100Pa\u003cbr\u003e•    200 mm duct diameter \u003cbr\u003e•    Side and rear spigot options to external pipes \u003cbr\u003e•    Up to 75% heat Recovery rate \u003cbr\u003e•    Lossnay paper core enables total heat exchange (sensible and latent) \u003cbr\u003e•    compliance with Part L\u003cbr\u003e•    Optional Mitsubishi Electric energy saving CO2 sensors \u003cbr\u003e•    100% Summer By-Pass\u003cbr\u003e•    Lightweight structure ideal for easy ceiling installation\u003cbr\u003e•    Vertical installation available for flexibility of application\u003cbr\u003e•    Optional digital Controller\u003cbr\u003e•    Optional F7 filtration\u003cbr\u003e•    0-10V input option.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eControllability\u003c\/h3\u003e\n\u003cp\u003e•    Volt Free contact\u003cbr\u003e•    PCB Dipswitch function\u003cbr\u003e•    Optional Controller\u003cbr\u003e•    Optional 12v signal \u003cbr\u003e•    Optional External sensors\u003cbr\u003e•    Optional 0-10v DC Input \u003cbr\u003e•    Optional Wi-Fi Interface \u003cbr\u003e•    Optional M-Net connectivity \u003cbr\u003e•    Control compatibility with Mr Slim and City Multi air conditioning systems for a complete and highly effective system operation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaycontrol.png?v=1739274693\"\u003e\u003c\/p\u003e\n\u003ch3\u003eWall LCD controller (optional)\u003c\/h3\u003e\n\u003cp\u003eThe optional wall controller PZ-62DR-EB will allow you to \u003cbr\u003e•    Adjust Fan Speed in 5% increments\u003cbr\u003e•    Automatic control\u003cbr\u003e•    Filter warning \u003cbr\u003e•    Weekley Timer \u003cbr\u003e•    Nighttime Purge\u003cbr\u003e•    Summer By-Pass\u003cbr\u003e•    Temperature \u003cbr\u003e•    Optional Co2 display\u003cbr\u003e•    Maintenance and Run Time \u003cbr\u003e•    Connect to other Mitsubishi products \u003cbr\u003e•    Operate Multiple Units (max 15)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaytimer.png?v=1739274788\"\u003e\u003c\/p\u003e\n\u003ch3\u003eCo2 Sensors\u003c\/h3\u003e\n\u003cp\u003eWith the option of an additional CO2 sensor. When connected with the optional Wi-Fi Control Interface, CO2 levels can be viewed in real-time making it ideal for schools, medical facilities and offices.\u003cbr\u003eIt is well known that poor air quality impacts health, wellbeing and concentration levels. In conjunction with the CO2 sensor, the Lossnay LGH-RVX3-E system intuitively adjusts airflow to ensure optimum air quality, no matter how many people are in the room.\u003cbr\u003eTwo types of CO2 sensors are available: wall-mounted and duct-mounted types. Power is supplied to the CO2 sensor from the Lossnay board.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaysensors.png?v=1739274868\"\u003e\u003c\/p\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cp\u003eThe Mitsubishi LGH units’ range are manufactured of airtight and noise absorbing EPP with a metal outer cover\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaymotors.png?v=1739274952\"\u003e\u003c\/p\u003e\n\u003ch3\u003eMotors\u003c\/h3\u003e\n\u003cp\u003eHigh quality commercial motors with Dual-Barrier coating on the fan prevents dust and grease accumulation, ensuring long-term efficient operation\u003c\/p\u003e\n\u003cp\u003eFlexible supply and exhaust fan commissioning in 5% increments, offering low running costs and easier\u003c\/p\u003e\n\u003cp\u003eThe default fan speed value (Fan speed 1: 25%, Fan speed 2: 50%, Fan speed 3: 75%, and Fan speed 4: 100%) of both supply air and exhaust air can be adjusted flexibly. Within the range between 25% and 100%, airflow can be adjusted by 5% increments to satisfactorily meet the designed airflow rate.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDual Barrier Coating\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDual Barrier Coating prevents dust and oil build-up on the interior of the Lossnay unit, helping to keep it clean for optimal performance. A water-repellent effect is achieved by creating a coating film that has nano-sized concave-convex structures formed by silica nanoparticles made of water-repellent fluor resin and micron-sized concave-convex structures formed by combining micronized special-shaped particles (silicate) with the silica nanoparticles. At the same time, the uneven structure forms an air layer that suppresses the adhesion of dust and sand that contain a lot of humidity, reducing the amount of dirt that adheres to the substrate.\u003c\/p\u003e\n\u003ch3\u003eFiltration\u003c\/h3\u003e\n\u003cp\u003e•    2 x G3 filters are fitted to the unit that are easy to replace \u003cbr\u003e•    Optional F7 to air supply\u003c\/p\u003e\n\u003ch3\u003eSummer By-Pass\u003c\/h3\u003e\n\u003cp\u003eThe units have a 100% summer by-Pass \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnayheatexchange.png?v=1739275095\"\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003eHeat Exchanger\u003c\/h3\u003e\n\u003cp\u003eThe key to Lossnay is the unique heat transfer core. Through the Lossnay Core, up to 88%* of the energy in the stale exhaust air is recovered and transferred to pre-warm (or cool) incoming fresh, filtered air.\u003c\/p\u003e\n\u003cp\u003eFor example, in winter a building that has an inside temperature of 20°C and 4°C air outside, the incoming fresh air can be warmed to over 18°C by transferring through a Lossnay Ventilation System and benefitting from the efficient energy transfer process. The building’s air conditioning systems no longer have to work as hard to maintain desired indoor air temperatures.\u003c\/p\u003e\n\u003cp\u003eLossnay LGH-RVX3-E models are equipped with chemically treated paper core to recover sensible and latent heat from the outgoing stale air to pre-warm (or pre-cool) incoming fresh air to achieve higher levels of heat recovery, resulting in both cost and energy savings\u003c\/p\u003e\n\u003cp\u003eThe paper core is Not Suitable for extracting from areas of High Humidity (showers rooms etc)\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003eFrost Protection\u003c\/h3\u003e\n\u003cp\u003eThe unit has a frost protection programme \u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003e\u003cspan style=\"font-size: 10.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-color-alt: windowtext; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnayheatexchangeunit.png?v=1739275187\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eOrientation\u003c\/h3\u003e\n\u003cp\u003eThe unit is available in only one orientation \u003cbr\u003eThe external pipes can be repositioned from the rear to side if required \u003c\/p\u003e\n\u003ch3\u003eMounting\u003c\/h3\u003e\n\u003cp\u003eThe units are supplied with ceiling mounting brackets and optional wall mounting brackets are available\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eMitsubishi offer a 3-year warranty with this unit\u003c\/p\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e•    Remote controller – PZ-62DR-EB\u003cbr\u003e•    Standard Filters – PZ-80RF3-E\u003cbr\u003e•    F7 Filter – PZ-80RFP3-E\u003cbr\u003e•    Wall Mounted Co2 Sensor – PZ-70CSW-E\u003cbr\u003e•    Duct Mounted Co2 Sensor – PZ-70CSD-E\u003cbr\u003e•    Vertical Mounting Bracket – PZ-2VS-E\u003c\/p\u003e\n\u003ch3\u003eFurther Information\u003c\/h3\u003e\n\u003cp\u003eFurther information is available on the \u003ca href=\"https:\/\/les.mitsubishielectric.co.uk\/products\/ventilation\/commercial-ventilation-units\/commercial-lossnay-series\/rvx3\"\u003eManufactures website\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":53736451735878,"sku":"LGH50RVX3-E","price":1474.67,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/rvx3-e-commercial-lossnay-ventilation_1_1_1.jpg?v=1732556262"},{"product_id":"mitsubishi-lossnay-lgh-65rvx3-e","title":"Mitsubishi Lossnay LGH-65RVX3-E","description":"\u003cp\u003e•    Suitable for commercial offices and schools \u003cbr\u003e•    Airflow Rate of 650 m3\/hr @ 100Pa\u003cbr\u003e•    200 mm duct diameter \u003cbr\u003e•    Side and rear spigot options to external pipes \u003cbr\u003e•    Up to 82% heat Recovery rate \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Mitsubishi LGH-65 RVX3-E is one of the most popular commercial heat recovery units and are suitable for any type of commercial application including Schools and Offices or any property that do not require extraction from showers or other areas of high humidity    \u003c\/p\u003e\n\u003cp\u003eBPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems,\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 14.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003eKey features- Mitsubishi Lossnay LGH-65 RVX3-E\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e•    Airflow Rate of 650 m3\/hr @ 100Pa\u003cbr\u003e•    200 mm duct diameter \u003cbr\u003e•    Side and rear spigot options to external pipes \u003cbr\u003e•    Up to 82% heat Recovery rate \u003cbr\u003e•    Lossnay paper core enables total heat exchange (sensible and latent) \u003cbr\u003e•    compliance with Part L\u003cbr\u003e•    Optional Mitsubishi Electric energy saving CO2 sensors \u003cbr\u003e•    100% Summer By-Pass\u003cbr\u003e•    Lightweight structure ideal for easy ceiling installation\u003cbr\u003e•    Vertical installation available for flexibility of application\u003cbr\u003e•    Optional digital Controller\u003cbr\u003e•    Optional F7 filtration\u003cbr\u003e•    0-10V input option.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eControllability\u003c\/h3\u003e\n\u003cp\u003e•    Volt Free contact\u003cbr\u003e•    PCB Dipswitch function\u003cbr\u003e•    Optional Controller\u003cbr\u003e•    Optional 12v signal \u003cbr\u003e•    Optional External sensors\u003cbr\u003e•    Optional 0-10v DC Input \u003cbr\u003e•    Optional Wi-Fi Interface \u003cbr\u003e•    Optional M-Net connectivity \u003cbr\u003e•    Control compatibility with Mr Slim and City Multi air conditioning systems for a complete and highly effective system operation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaycontrol.png?v=1739274693\"\u003e\u003c\/p\u003e\n\u003ch3\u003eWall LCD controller (optional)\u003c\/h3\u003e\n\u003cp\u003eThe optional wall controller PZ-62DR-EB will allow you to \u003cbr\u003e•    Adjust Fan Speed in 5% increments\u003cbr\u003e•    Automatic control\u003cbr\u003e•    Filter warning \u003cbr\u003e•    Weekley Timer \u003cbr\u003e•    Nighttime Purge\u003cbr\u003e•    Summer By-Pass\u003cbr\u003e•    Temperature \u003cbr\u003e•    Optional Co2 display\u003cbr\u003e•    Maintenance and Run Time \u003cbr\u003e•    Connect to other Mitsubishi products \u003cbr\u003e•    Operate Multiple Units (max 15)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaytimer.png?v=1739274788\"\u003e\u003c\/p\u003e\n\u003ch3\u003eCo2 Sensors\u003c\/h3\u003e\n\u003cp\u003eWith the option of an additional CO2 sensor. When connected with the optional Wi-Fi Control Interface, CO2 levels can be viewed in real-time making it ideal for schools, medical facilities and offices.\u003cbr\u003eIt is well known that poor air quality impacts health, wellbeing and concentration levels. In conjunction with the CO2 sensor, the Lossnay LGH-RVX3-E system intuitively adjusts airflow to ensure optimum air quality, no matter how many people are in the room.\u003cbr\u003eTwo types of CO2 sensors are available: wall-mounted and duct-mounted types. Power is supplied to the CO2 sensor from the Lossnay board.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaysensors.png?v=1739274868\"\u003e\u003c\/p\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cp\u003eThe Mitsubishi LGH units’ range are manufactured of airtight and noise absorbing EPP with a metal outer cover\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaymotors.png?v=1739274952\"\u003e\u003c\/p\u003e\n\u003ch3\u003eMotors\u003c\/h3\u003e\n\u003cp\u003eHigh quality commercial motors with Dual-Barrier coating on the fan prevents dust and grease accumulation, ensuring long-term efficient operation\u003c\/p\u003e\n\u003cp\u003eFlexible supply and exhaust fan commissioning in 5% increments, offering low running costs and easier\u003c\/p\u003e\n\u003cp\u003eThe default fan speed value (Fan speed 1: 25%, Fan speed 2: 50%, Fan speed 3: 75%, and Fan speed 4: 100%) of both supply air and exhaust air can be adjusted flexibly. Within the range between 25% and 100%, airflow can be adjusted by 5% increments to satisfactorily meet the designed airflow rate.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDual Barrier Coating\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDual Barrier Coating prevents dust and oil build-up on the interior of the Lossnay unit, helping to keep it clean for optimal performance. A water-repellent effect is achieved by creating a coating film that has nano-sized concave-convex structures formed by silica nanoparticles made of water-repellent fluor resin and micron-sized concave-convex structures formed by combining micronized special-shaped particles (silicate) with the silica nanoparticles. At the same time, the uneven structure forms an air layer that suppresses the adhesion of dust and sand that contain a lot of humidity, reducing the amount of dirt that adheres to the substrate.\u003c\/p\u003e\n\u003ch3\u003eFiltration\u003c\/h3\u003e\n\u003cp\u003e•    2 x G3 filters are fitted to the unit that are easy to replace \u003cbr\u003e•    Optional F7 to air supply\u003c\/p\u003e\n\u003ch3\u003eSummer By-Pass\u003c\/h3\u003e\n\u003cp\u003eThe units have a 100% summer by-Pass \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnayheatexchange.png?v=1739275095\"\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003eHeat Exchanger\u003c\/h3\u003e\n\u003cp\u003eThe key to Lossnay is the unique heat transfer core. Through the Lossnay Core, up to 88%* of the energy in the stale exhaust air is recovered and transferred to pre-warm (or cool) incoming fresh, filtered air.\u003c\/p\u003e\n\u003cp\u003eFor example, in winter a building that has an inside temperature of 20°C and 4°C air outside, the incoming fresh air can be warmed to over 18°C by transferring through a Lossnay Ventilation System and benefitting from the efficient energy transfer process. The building’s air conditioning systems no longer have to work as hard to maintain desired indoor air temperatures.\u003c\/p\u003e\n\u003cp\u003eLossnay LGH-RVX3-E models are equipped with chemically treated paper core to recover sensible and latent heat from the outgoing stale air to pre-warm (or pre-cool) incoming fresh air to achieve higher levels of heat recovery, resulting in both cost and energy savings\u003c\/p\u003e\n\u003cp\u003eThe paper core is Not Suitable for extracting from areas of High Humidity (showers rooms etc)\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003eFrost Protection\u003c\/h3\u003e\n\u003cp\u003eThe unit has a frost protection programme \u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003e\u003cspan style=\"font-size: 10.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-color-alt: windowtext; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnayheatexchangeunit.png?v=1739275187\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eOrientation\u003c\/h3\u003e\n\u003cp\u003eThe unit is available in only one orientation \u003cbr\u003eThe external pipes can be repositioned from the rear to side if required \u003c\/p\u003e\n\u003ch3\u003eMounting\u003c\/h3\u003e\n\u003cp\u003eThe units are supplied with ceiling mounting brackets and optional wall mounting brackets are available\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eMitsubishi offer a 3-year warranty with this unit\u003c\/p\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e•    Remote controller – PZ-62DR-EB\u003cbr\u003e•    Standard Filters – PZ-80RF3-E\u003cbr\u003e•    F7 Filter – PZ-80RFP3-E\u003cbr\u003e•    Wall Mounted Co2 Sensor – PZ-70CSW-E\u003cbr\u003e•    Duct Mounted Co2 Sensor – PZ-70CSD-E\u003cbr\u003e•    Vertical Mounting Bracket – PZ-2VS-E\u003c\/p\u003e\n\u003ch3\u003eFurther Information\u003c\/h3\u003e\n\u003cp\u003eFurther information is available on the \u003ca href=\"https:\/\/les.mitsubishielectric.co.uk\/products\/ventilation\/commercial-ventilation-units\/commercial-lossnay-series\/rvx3\"\u003eManufactures website\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":53736451768646,"sku":"LGH65RVX3-E","price":1842.76,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/rvx3-e-commercial-lossnay-ventilation_1_1_1_1.jpg?v=1732556270"},{"product_id":"mitsubishi-lossnay-lgh-80rvx3-e","title":"Mitsubishi Lossnay LGH-80RVX3-E","description":"\u003cp\u003e•    Suitable for commercial offices and schools \u003cbr\u003e•    Airflow Rate of 800 m3\/hr @ 100Pa\u003cbr\u003e•    250 mm duct diameter \u003cbr\u003e•    Side and rear spigot options to external pipes \u003cbr\u003e•    Up to 80% heat Recovery rate \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Mitsubishi LGH-80 RVX3-E is one of the most popular commercial heat recovery units and are suitable for any type of commercial application including Schools and Offices or any property that do not require extraction from showers or other areas of high humidity  \u003c\/p\u003e\n\u003cp\u003eBPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems,\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 14.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003eKey features- Mitsubishi Lossnay LGH-80 RVX3-E\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e•    Airflow Rate of 800 m3\/hr @ 100Pa\u003cbr\u003e•    250 mm duct diameter \u003cbr\u003e•    Side and rear spigot options to external pipes \u003cbr\u003e•    Up to 80% heat Recovery rate \u003cbr\u003e•    Lossnay paper core enables total heat exchange (sensible and latent) \u003cbr\u003e•    compliance with Part L\u003cbr\u003e•    Optional Mitsubishi Electric energy saving CO2 sensors \u003cbr\u003e•    100% Summer By-Pass\u003cbr\u003e•    Lightweight structure ideal for easy ceiling installation\u003cbr\u003e•    Vertical installation available for flexibility of application\u003cbr\u003e•    Optional digital Controller\u003cbr\u003e•    Optional F7 filtration\u003cbr\u003e•    0-10V input option.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eControllability\u003c\/h3\u003e\n\u003cp\u003e•    Volt Free contact\u003cbr\u003e•    PCB Dipswitch function\u003cbr\u003e•    Optional Controller\u003cbr\u003e•    Optional 12v signal \u003cbr\u003e•    Optional External sensors\u003cbr\u003e•    Optional 0-10v DC Input \u003cbr\u003e•    Optional Wi-Fi Interface \u003cbr\u003e•    Optional M-Net connectivity \u003cbr\u003e•    Control compatibility with Mr Slim and City Multi air conditioning systems for a complete and highly effective system operation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaycontrol.png?v=1739274693\"\u003e\u003c\/p\u003e\n\u003ch3\u003eWall LCD controller (optional)\u003c\/h3\u003e\n\u003cp\u003eThe optional wall controller PZ-62DR-EB will allow you to \u003cbr\u003e•    Adjust Fan Speed in 5% increments\u003cbr\u003e•    Automatic control\u003cbr\u003e•    Filter warning \u003cbr\u003e•    Weekley Timer \u003cbr\u003e•    Nighttime Purge\u003cbr\u003e•    Summer By-Pass\u003cbr\u003e•    Temperature \u003cbr\u003e•    Optional Co2 display\u003cbr\u003e•    Maintenance and Run Time \u003cbr\u003e•    Connect to other Mitsubishi products \u003cbr\u003e•    Operate Multiple Units (max 15)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaytimer.png?v=1739274788\"\u003e\u003c\/p\u003e\n\u003ch3\u003eCo2 Sensors\u003c\/h3\u003e\n\u003cp\u003eWith the option of an additional CO2 sensor. When connected with the optional Wi-Fi Control Interface, CO2 levels can be viewed in real-time making it ideal for schools, medical facilities and offices.\u003cbr\u003eIt is well known that poor air quality impacts health, wellbeing and concentration levels. In conjunction with the CO2 sensor, the Lossnay LGH-RVX3-E system intuitively adjusts airflow to ensure optimum air quality, no matter how many people are in the room.\u003cbr\u003eTwo types of CO2 sensors are available: wall-mounted and duct-mounted types. Power is supplied to the CO2 sensor from the Lossnay board.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaysensors.png?v=1739274868\"\u003e\u003c\/p\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cp\u003eThe Mitsubishi LGH units’ range are manufactured of airtight and noise absorbing EPP with a metal outer cover\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaymotors.png?v=1739274952\"\u003e\u003c\/p\u003e\n\u003ch3\u003eMotors\u003c\/h3\u003e\n\u003cp\u003eHigh quality commercial motors with Dual-Barrier coating on the fan prevents dust and grease accumulation, ensuring long-term efficient operation\u003c\/p\u003e\n\u003cp\u003eFlexible supply and exhaust fan commissioning in 5% increments, offering low running costs and easier\u003c\/p\u003e\n\u003cp\u003eThe default fan speed value (Fan speed 1: 25%, Fan speed 2: 50%, Fan speed 3: 75%, and Fan speed 4: 100%) of both supply air and exhaust air can be adjusted flexibly. Within the range between 25% and 100%, airflow can be adjusted by 5% increments to satisfactorily meet the designed airflow rate.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDual Barrier Coating\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDual Barrier Coating prevents dust and oil build-up on the interior of the Lossnay unit, helping to keep it clean for optimal performance. A water-repellent effect is achieved by creating a coating film that has nano-sized concave-convex structures formed by silica nanoparticles made of water-repellent fluor resin and micron-sized concave-convex structures formed by combining micronized special-shaped particles (silicate) with the silica nanoparticles. At the same time, the uneven structure forms an air layer that suppresses the adhesion of dust and sand that contain a lot of humidity, reducing the amount of dirt that adheres to the substrate.\u003c\/p\u003e\n\u003ch3\u003eFiltration\u003c\/h3\u003e\n\u003cp\u003e•    2 x G3 filters are fitted to the unit that are easy to replace \u003cbr\u003e•    Optional F7 to air supply\u003c\/p\u003e\n\u003ch3\u003eSummer By-Pass\u003c\/h3\u003e\n\u003cp\u003eThe units have a 100% summer by-Pass \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnayheatexchange.png?v=1739275095\"\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003eHeat Exchanger\u003c\/h3\u003e\n\u003cp\u003eThe key to Lossnay is the unique heat transfer core. Through the Lossnay Core, up to 88%* of the energy in the stale exhaust air is recovered and transferred to pre-warm (or cool) incoming fresh, filtered air.\u003c\/p\u003e\n\u003cp\u003eFor example, in winter a building that has an inside temperature of 20°C and 4°C air outside, the incoming fresh air can be warmed to over 18°C by transferring through a Lossnay Ventilation System and benefitting from the efficient energy transfer process. The building’s air conditioning systems no longer have to work as hard to maintain desired indoor air temperatures.\u003c\/p\u003e\n\u003cp\u003eLossnay LGH-RVX3-E models are equipped with chemically treated paper core to recover sensible and latent heat from the outgoing stale air to pre-warm (or pre-cool) incoming fresh air to achieve higher levels of heat recovery, resulting in both cost and energy savings\u003c\/p\u003e\n\u003cp\u003eThe paper core is Not Suitable for extracting from areas of High Humidity (showers rooms etc)\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003eFrost Protection\u003c\/h3\u003e\n\u003cp\u003eThe unit has a frost protection programme \u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003e\u003cspan style=\"font-size: 10.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-color-alt: windowtext; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnayheatexchangeunit.png?v=1739275187\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eOrientation\u003c\/h3\u003e\n\u003cp\u003eThe unit is available in only one orientation \u003cbr\u003eThe external pipes can be repositioned from the rear to side if required \u003c\/p\u003e\n\u003ch3\u003eMounting\u003c\/h3\u003e\n\u003cp\u003eThe units are supplied with ceiling mounting brackets and optional wall mounting brackets are available\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eMitsubishi offer a 3-year warranty with this unit\u003c\/p\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e•    Remote controller – PZ-62DR-EB\u003cbr\u003e•    Standard Filters – PZ-80RF3-E\u003cbr\u003e•    F7 Filter – PZ-80RFP3-E\u003cbr\u003e•    Wall Mounted Co2 Sensor – PZ-70CSW-E\u003cbr\u003e•    Duct Mounted Co2 Sensor – PZ-70CSD-E\u003cbr\u003e•    Vertical Mounting Bracket – PZ-2VS-E\u003c\/p\u003e\n\u003ch3\u003eFurther Information\u003c\/h3\u003e\n\u003cp\u003eFurther information is available on the \u003ca href=\"https:\/\/les.mitsubishielectric.co.uk\/products\/ventilation\/commercial-ventilation-units\/commercial-lossnay-series\/rvx3\"\u003eManufactures website\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":53736451801414,"sku":"LGH80RVX3-E","price":2158.08,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/rvx3-e-commercial-lossnay-ventilation_1_1_1_1_1.jpg?v=1732556279"},{"product_id":"mitsubishi-lossnay-lgh-80rvx3-e-1","title":"Mitsubishi Lossnay LGH-100RVX3-E","description":"\u003cp\u003e•    Suitable for commercial offices and schools \u003cbr\u003e•    Airflow Rate of 1000 m3\/hr @ 100Pa\u003cbr\u003e•    250 mm duct diameter \u003cbr\u003e•    Side and rear spigot options to external pipes \u003cbr\u003e•    Up to 83% heat Recovery rate\u003c\/p\u003e\n\u003cp\u003eThe Mitsubishi LGH-100 RVX3-E is one of the most popular commercial heat recovery units and are suitable for any type of commercial application including Schools and Offices or any property that do not require extraction from showers or other areas of high humidity  \u003c\/p\u003e\n\u003cp\u003eBPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems,\u003c\/p\u003e\n\u003ch3\u003eKey features- Mitsubishi Lossnay LGH-100 RVX3-E\u003c\/h3\u003e\n\u003cp\u003e•    Airflow Rate of 1000 m3\/hr @ 100Pa\u003cbr\u003e•    250 mm duct diameter \u003cbr\u003e•    Side and rear spigot options to external pipes \u003cbr\u003e•    Up to 83% heat Recovery rate \u003cbr\u003e•    Lossnay paper core enables total heat exchange (sensible and latent) \u003cbr\u003e•    compliance with Part L\u003cbr\u003e•    Optional Mitsubishi Electric energy saving CO2 sensors \u003cbr\u003e•    100% Summer By-Pass\u003cbr\u003e•    Lightweight structure ideal for easy ceiling installation\u003cbr\u003e•    Vertical installation available for flexibility of application\u003cbr\u003e•    Optional digital Controller\u003cbr\u003e•    Optional F7 filtration\u003cbr\u003e•    0-10V input option.\u003c\/p\u003e\n\u003ch3\u003eControllability\u003c\/h3\u003e\n\u003cp\u003e•    Volt Free contact\u003cbr\u003e•    PCB Dipswitch function\u003cbr\u003e•    Optional Controller\u003cbr\u003e•    Optional 12v signal \u003cbr\u003e•    Optional External sensors\u003cbr\u003e•    Optional 0-10v DC Input \u003cbr\u003e•    Optional Wi-Fi Interface \u003cbr\u003e•    Optional M-Net connectivity \u003cbr\u003e•    Control compatibility with Mr Slim and City Multi air conditioning systems for a complete and highly effective system operation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaycontrol.png?v=1739274693\"\u003e\u003c\/p\u003e\n\u003ch3\u003eWall LCD controller (optional)\u003c\/h3\u003e\n\u003cp\u003eThe optional wall controller PZ-62DR-EB will allow you to \u003cbr\u003e•    Adjust Fan Speed in 5% increments\u003cbr\u003e•    Automatic control\u003cbr\u003e•    Filter warning \u003cbr\u003e•    Weekley Timer \u003cbr\u003e•    Nighttime Purge\u003cbr\u003e•    Summer By-Pass\u003cbr\u003e•    Temperature \u003cbr\u003e•    Optional Co2 display\u003cbr\u003e•    Maintenance and Run Time \u003cbr\u003e•    Connect to other Mitsubishi products \u003cbr\u003e•    Operate Multiple Units (max 15)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaytimer.png?v=1739274788\"\u003e\u003c\/p\u003e\n\u003ch3\u003eCo2 Sensors\u003c\/h3\u003e\n\u003cp\u003eWith the option of an additional CO2 sensor. When connected with the optional Wi-Fi Control Interface, CO2 levels can be viewed in real-time making it ideal for schools, medical facilities and offices.\u003cbr\u003eIt is well known that poor air quality impacts health, wellbeing and concentration levels. In conjunction with the CO2 sensor, the Lossnay LGH-RVX3-E system intuitively adjusts airflow to ensure optimum air quality, no matter how many people are in the room.\u003cbr\u003eTwo types of CO2 sensors are available: wall-mounted and duct-mounted types. Power is supplied to the CO2 sensor from the Lossnay board.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaysensors.png?v=1739274868\"\u003e\u003c\/p\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cp\u003eThe Mitsubishi LGH units’ range are manufactured of airtight and noise absorbing EPP with a metal outer cover\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaymotors.png?v=1739274952\"\u003e\u003c\/p\u003e\n\u003ch3\u003eMotors\u003c\/h3\u003e\n\u003cp\u003eHigh quality commercial motors with Dual-Barrier coating on the fan prevents dust and grease accumulation, ensuring long-term efficient operation\u003c\/p\u003e\n\u003cp\u003eFlexible supply and exhaust fan commissioning in 5% increments, offering low running costs and easier\u003c\/p\u003e\n\u003cp\u003eThe default fan speed value (Fan speed 1: 25%, Fan speed 2: 50%, Fan speed 3: 75%, and Fan speed 4: 100%) of both supply air and exhaust air can be adjusted flexibly. Within the range between 25% and 100%, airflow can be adjusted by 5% increments to satisfactorily meet the designed airflow rate.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDual Barrier Coating\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDual Barrier Coating prevents dust and oil build-up on the interior of the Lossnay unit, helping to keep it clean for optimal performance. A water-repellent effect is achieved by creating a coating film that has nano-sized concave-convex structures formed by silica nanoparticles made of water-repellent fluor resin and micron-sized concave-convex structures formed by combining micronized special-shaped particles (silicate) with the silica nanoparticles. At the same time, the uneven structure forms an air layer that suppresses the adhesion of dust and sand that contain a lot of humidity, reducing the amount of dirt that adheres to the substrate.\u003c\/p\u003e\n\u003ch3\u003eFiltration\u003c\/h3\u003e\n\u003cp\u003e•    2 x G3 filters are fitted to the unit that are easy to replace \u003cbr\u003e•    Optional F7 to air supply\u003c\/p\u003e\n\u003ch3\u003eSummer By-Pass\u003c\/h3\u003e\n\u003cp\u003eThe units have a 100% summer by-Pass \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnayheatexchange.png?v=1739275095\"\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003eHeat Exchanger\u003c\/h3\u003e\n\u003cp\u003eThe key to Lossnay is the unique heat transfer core. Through the Lossnay Core, up to 88%* of the energy in the stale exhaust air is recovered and transferred to pre-warm (or cool) incoming fresh, filtered air.\u003c\/p\u003e\n\u003cp\u003eFor example, in winter a building that has an inside temperature of 20°C and 4°C air outside, the incoming fresh air can be warmed to over 18°C by transferring through a Lossnay Ventilation System and benefitting from the efficient energy transfer process. The building’s air conditioning systems no longer have to work as hard to maintain desired indoor air temperatures.\u003c\/p\u003e\n\u003cp\u003eLossnay LGH-RVX3-E models are equipped with chemically treated paper core to recover sensible and latent heat from the outgoing stale air to pre-warm (or pre-cool) incoming fresh air to achieve higher levels of heat recovery, resulting in both cost and energy savings\u003c\/p\u003e\n\u003cp\u003eThe paper core is Not Suitable for extracting from areas of High Humidity (showers rooms etc)\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003eFrost Protection\u003c\/h3\u003e\n\u003cp\u003eThe unit has a frost protection programme \u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003e\u003cspan style=\"font-size: 10.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-color-alt: windowtext; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnayheatexchangeunit.png?v=1739275187\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eOrientation\u003c\/h3\u003e\n\u003cp\u003eThe unit is available in only one orientation \u003cbr\u003eThe external pipes can be repositioned from the rear to side if required \u003c\/p\u003e\n\u003ch3\u003eMounting\u003c\/h3\u003e\n\u003cp\u003eThe units are supplied with ceiling mounting brackets and optional wall mounting brackets are available\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eMitsubishi offer a 3-year warranty with this unit\u003c\/p\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e•    Remote controller – PZ-62DR-EB\u003cbr\u003e•    Standard Filters – PZ-80RF3-E\u003cbr\u003e•    F7 Filter – PZ-80RFP3-E\u003cbr\u003e•    Wall Mounted Co2 Sensor – PZ-70CSW-E\u003cbr\u003e•    Duct Mounted Co2 Sensor – PZ-70CSD-E\u003cbr\u003e•    Vertical Mounting Bracket – PZ-2VS-E\u003c\/p\u003e\n\u003ch3\u003eFurther Information\u003c\/h3\u003e\n\u003cp\u003eFurther information is available on the \u003ca href=\"https:\/\/les.mitsubishielectric.co.uk\/products\/ventilation\/commercial-ventilation-units\/commercial-lossnay-series\/rvx3\"\u003eManufactures website\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":53736451834182,"sku":"LGH100RVX3-E","price":2476.92,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/rvx3-e-commercial-lossnay-ventilation_1_1_1_1_1_1.jpg?v=1732556253"},{"product_id":"mitsubishi-lgh200rvx3-e","title":"Mitsubishi LGH200RVX3-E","description":"\u003cp\u003e•    Suitable for commercial offices and schools \u003cbr\u003e•    Airflow Rate of 2000 m3\/hr @ 100Pa\u003cbr\u003e•    4 x 250 mm duct diameter \u003cbr\u003e•    Side and rear spigot options to external pipes \u003cbr\u003e•    Up to 83% heat Recovery rate \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Mitsubishi LGH-200 RVX3-E are suitable for any type of commercial application including Schools and Offices or any property that do not require extraction from showers or other areas of high humidity  \u003c\/p\u003e\n\u003cp\u003ePlease note the depth of this unit and due to 4 x spigots you may require additional transition pieces to connect to ductwork \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eBPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems,\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 14.0pt; line-height: 107%; font-family: 'Arial',sans-serif;\"\u003eKey features- Mitsubishi Lossnay LGH-200 RVX3-E\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e•    Airflow Rate of 2000 m3\/hr @ 100Pa\u003cbr\u003e•    4 x 250 mm duct diameter \u003cbr\u003e•    Side and rear spigot options to external pipes \u003cbr\u003e•    Up to 83% heat Recovery rate \u003cbr\u003e•    Lossnay paper core enables total heat exchange (sensible and latent) \u003cbr\u003e•    compliance with Part L\u003cbr\u003e•    Optional Mitsubishi Electric energy saving CO2 sensors \u003cbr\u003e•    100% Summer By-Pass\u003cbr\u003e•    Lightweight structure ideal for easy ceiling installation\u003cbr\u003e•    Vertical installation available for flexibility of application\u003cbr\u003e•    Optional digital Controller\u003cbr\u003e•    Optional F7 filtration\u003cbr\u003e•    0-10V input option.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eControllability\u003c\/h3\u003e\n\u003cp\u003e•    Volt Free contact\u003cbr\u003e•    PCB Dipswitch function\u003cbr\u003e•    Optional Controller\u003cbr\u003e•    Optional 12v signal \u003cbr\u003e•    Optional External sensors\u003cbr\u003e•    Optional 0-10v DC Input \u003cbr\u003e•    Optional Wi-Fi Interface \u003cbr\u003e•    Optional M-Net connectivity \u003cbr\u003e•    Control compatibility with Mr Slim and City Multi air conditioning systems for a complete and highly effective system operation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaycontrol.png?v=1739274693\"\u003e\u003c\/p\u003e\n\u003ch3\u003eWall LCD controller (optional)\u003c\/h3\u003e\n\u003cp\u003eThe optional wall controller PZ-62DR-EB will allow you to \u003cbr\u003e•    Adjust Fan Speed in 5% increments\u003cbr\u003e•    Automatic control\u003cbr\u003e•    Filter warning \u003cbr\u003e•    Weekley Timer \u003cbr\u003e•    Nighttime Purge\u003cbr\u003e•    Summer By-Pass\u003cbr\u003e•    Temperature \u003cbr\u003e•    Optional Co2 display\u003cbr\u003e•    Maintenance and Run Time \u003cbr\u003e•    Connect to other Mitsubishi products \u003cbr\u003e•    Operate Multiple Units (max 15)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaytimer.png?v=1739274788\"\u003e\u003c\/p\u003e\n\u003ch3\u003eCo2 Sensors\u003c\/h3\u003e\n\u003cp\u003eWith the option of an additional CO2 sensor. When connected with the optional Wi-Fi Control Interface, CO2 levels can be viewed in real-time making it ideal for schools, medical facilities and offices.\u003cbr\u003eIt is well known that poor air quality impacts health, wellbeing and concentration levels. In conjunction with the CO2 sensor, the Lossnay LGH-RVX3-E system intuitively adjusts airflow to ensure optimum air quality, no matter how many people are in the room.\u003cbr\u003eTwo types of CO2 sensors are available: wall-mounted and duct-mounted types. Power is supplied to the CO2 sensor from the Lossnay board.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaysensors.png?v=1739274868\"\u003e\u003c\/p\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cp\u003eThe Mitsubishi LGH units’ range are manufactured of airtight and noise absorbing EPP with a metal outer cover\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnaymotors.png?v=1739274952\"\u003e\u003c\/p\u003e\n\u003ch3\u003eMotors\u003c\/h3\u003e\n\u003cp\u003eHigh quality commercial motors with Dual-Barrier coating on the fan prevents dust and grease accumulation, ensuring long-term efficient operation\u003c\/p\u003e\n\u003cp\u003eFlexible supply and exhaust fan commissioning in 5% increments, offering low running costs and easier\u003c\/p\u003e\n\u003cp\u003eThe default fan speed value (Fan speed 1: 25%, Fan speed 2: 50%, Fan speed 3: 75%, and Fan speed 4: 100%) of both supply air and exhaust air can be adjusted flexibly. Within the range between 25% and 100%, airflow can be adjusted by 5% increments to satisfactorily meet the designed airflow rate.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDual Barrier Coating\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDual Barrier Coating prevents dust and oil build-up on the interior of the Lossnay unit, helping to keep it clean for optimal performance. A water-repellent effect is achieved by creating a coating film that has nano-sized concave-convex structures formed by silica nanoparticles made of water-repellent fluor resin and micron-sized concave-convex structures formed by combining micronized special-shaped particles (silicate) with the silica nanoparticles. At the same time, the uneven structure forms an air layer that suppresses the adhesion of dust and sand that contain a lot of humidity, reducing the amount of dirt that adheres to the substrate.\u003c\/p\u003e\n\u003ch3\u003eFiltration\u003c\/h3\u003e\n\u003cp\u003e•    2 x G3 filters are fitted to the unit that are easy to replace \u003cbr\u003e•    Optional F7 to air supply\u003c\/p\u003e\n\u003ch3\u003eSummer By-Pass\u003c\/h3\u003e\n\u003cp\u003eThe units have a 100% summer by-Pass \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnayheatexchange.png?v=1739275095\"\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003eHeat Exchanger\u003c\/h3\u003e\n\u003cp\u003eThe key to Lossnay is the unique heat transfer core. Through the Lossnay Core, up to 88%* of the energy in the stale exhaust air is recovered and transferred to pre-warm (or cool) incoming fresh, filtered air.\u003c\/p\u003e\n\u003cp\u003eFor example, in winter a building that has an inside temperature of 20°C and 4°C air outside, the incoming fresh air can be warmed to over 18°C by transferring through a Lossnay Ventilation System and benefitting from the efficient energy transfer process. The building’s air conditioning systems no longer have to work as hard to maintain desired indoor air temperatures.\u003c\/p\u003e\n\u003cp\u003eLossnay LGH-RVX3-E models are equipped with chemically treated paper core to recover sensible and latent heat from the outgoing stale air to pre-warm (or pre-cool) incoming fresh air to achieve higher levels of heat recovery, resulting in both cost and energy savings\u003c\/p\u003e\n\u003cp\u003eThe paper core is Not Suitable for extracting from areas of High Humidity (showers rooms etc)\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003eFrost Protection\u003c\/h3\u003e\n\u003cp\u003eThe unit has a frost protection programme \u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-bottom-alt: auto; line-height: normal; background: white;\"\u003e\u003cspan style=\"font-size: 10.0pt; font-family: 'Arial',sans-serif; mso-fareast-font-family: 'Times New Roman'; color: black; mso-color-alt: windowtext; mso-font-kerning: 0pt; mso-ligatures: none; mso-fareast-language: EN-GB;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lossnayheatexchangeunit.png?v=1739275187\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eOrientation\u003c\/h3\u003e\n\u003cp\u003eThe unit is available in only one orientation \u003cbr\u003eThe external pipes can be repositioned from the rear to side if required \u003c\/p\u003e\n\u003ch3\u003eMounting\u003c\/h3\u003e\n\u003cp\u003eThe units are supplied with ceiling mounting brackets and optional wall mounting brackets are available\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eMitsubishi offer a 3-year warranty with this unit\u003c\/p\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e•    Remote controller – PZ-62DR-EB\u003cbr\u003e•    Standard Filters – PZ-80RF3-E\u003cbr\u003e•    F7 Filter – PZ-80RFP3-E\u003cbr\u003e•    Wall Mounted Co2 Sensor – PZ-70CSW-E\u003cbr\u003e•    Duct Mounted Co2 Sensor – PZ-70CSD-E\u003cbr\u003e•    Vertical Mounting Bracket – PZ-2VS-E\u003c\/p\u003e\n\u003ch3\u003eFurther Information\u003c\/h3\u003e\n\u003cp\u003eFurther information is available on the \u003ca href=\"https:\/\/les.mitsubishielectric.co.uk\/products\/ventilation\/commercial-ventilation-units\/commercial-lossnay-series\/rvx3\"\u003eManufactures website\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":53736451866950,"sku":"LGH200RVX3-E","price":4854.22,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/rvx3-100-160-_1.jpg?v=1732556261"},{"product_id":"bsk-scholar700-unit-1","title":"BSK Scholar 700 Classroom Heat Recovery Unit","description":"\u003ch2\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"\u003eBSK Scholar 700 Classroom Heat Recovery Unit\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"\u003e\u003cspan style=\"color: rgb(31, 201, 49);\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif;\"\u003ePossible 8 Week Lead Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"\u003ePart Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"\u003e Scholar 700\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHighly efficient heat recovery unit specially designed for classrooms, meeting rooms and offices with C02 demand control operation\u003c\/p\u003e\n\u003cp\u003eThese units get rid of dust, pollen, spores and other harmful particles to provide 100% fresh filtered air and can either recover up to 95% of normally wasted heat or provide comfort cooling via the free cooling mode\u003c\/p\u003e\n\u003cp\u003eBPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFully automatic control\u003c\/li\u003e\n\u003cli\u003eInternal Co2 sensors\u003c\/li\u003e\n\u003cli\u003eSuitable for offices with up to 24 staff\u003c\/li\u003e\n\u003cli\u003eAirflow rate 700m3\/h\u003c\/li\u003e\n\u003cli\u003e160m pipe connections\u003c\/li\u003e\n\u003cli\u003eUp to 95% heat recovery efficiency.\u003c\/li\u003e\n\u003cli\u003eFree cooling mode via By-Pass\u003c\/li\u003e\n\u003cli\u003eUnit mounted digital controller\u003c\/li\u003e\n\u003cli\u003eTop or rear external pipe spigots\u003c\/li\u003e\n\u003cli\u003e100% full and filtered modulating summer bypass\u003c\/li\u003e\n\u003cli\u003eInternal attenuating silencer\u003c\/li\u003e\n\u003cli\u003eAir quality pressure sensor\u003c\/li\u003e\n\u003cli\u003eTriple filter design of G4, G5 and F7 pollen filter\u003c\/li\u003e\n\u003cli\u003eDouble walled construction with 25mm sound insulation\u003c\/li\u003e\n\u003cli\u003eAnti draft electronic dampers to prevent draft when off\u003c\/li\u003e\n\u003cli\u003eFilter warning\u003c\/li\u003e\n\u003cli\u003eBMS integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/scholar500control_bd3e8dcd-c879-4324-97b5-1525dd6630b0.jpg?v=1732552989\" alt=\"\" width=\"332\" height=\"332\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eControllability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BSK Scholar has a unit mounted controller with a passcode that will allow the authorised person to adjust all setting including\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAir flow settings\u003c\/li\u003e\n\u003cli\u003etemperature,\u003c\/li\u003e\n\u003cli\u003eCo2 levels\u003c\/li\u003e\n\u003cli\u003eWeekley programme\u003c\/li\u003e\n\u003cli\u003eAuto Mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInternal Co2 Sensors \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAn internal mounted Co2 will boost the units speed when required\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBMS Control\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBMS integration is possible through the Modbus port on top of the unit\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBoost Input\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA boost input is positioned on top of the unit\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/Scholar500layout_e2a4dbce-dd81-400c-b5b8-9dc65b772708.png?v=1732552995\" alt=\"\" width=\"664\" height=\"574\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBoth the Scholar 500\/700 can be positioned against an external wall or at an internal wall and ducted to the outside (This method will give a slight decrease in performance due to the longer duct pressure increase, as the units are designed to be used with a short duct run or no ducting.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe casing is double walled 0.7mm galvanised steel filled with 25mm of sound insulation in order to keep the sound and heat insulation at the highest level. The outside as well as the inside surfaces of our devices are painted with electrostatic powder paint and deliver a long life, while providing a stylish and clean appearance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMotors\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eHighly efficient backward curved EC fans for maximum efficiency and performance\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFiltration \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA total of 3 filters are fitted as standard to supply superior filtration\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x G4 filter to exhaust air to outside\u003c\/li\u003e\n\u003cli\u003e1 x G4 pre filter to room air supply\u003c\/li\u003e\n\u003cli\u003e1 x F7 post filter to room air supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSummer By-Pass\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BSK Scholar range of units have a 100% summer by-Pass\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLow Noise Levels \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWith airtight, aerodynamic and sound absorbing construction with perfectly balanced fans the noise levels are ultra quiet\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHeat Exchanger \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Highest performing heat recovery exchanger that can recover up to 95% of otherwise lost heat\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrost Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe unit has a frost protection programme\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSilencer\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BSK Scholar as an internal silencer at the fresh air outlet of our device that allows silent\u003c\/p\u003e\n\u003cp\u003eoperation which provides a quiet working environment for classrooms or offices\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOrientation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOnly one orientation is possible\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eManufactured of powder coated galvanised steel outer cover for durability and an inside EPP lining for quietness and efficiency\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMounting \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe unit is floor mounted\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBSK offer a 2-year Parts warranty\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFurther Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFurther information is available on the Manufactures website \u003ca href=\"https:\/\/www.bskhvac.com.tr\/en\/product-detail\/heat-recovery-units\/scholar-high-efficiency-school-type-hru?kat=commercial-ventilation\"\u003e(Click Here)\u003c\/a\u003e\u003c\/p\u003e","brand":"BSK","offers":[{"title":"Default Title","offer_id":53736463335750,"sku":"Scholar 700","price":3084.14,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/bsk_scholar_2_3.jpg?v=1732556471"},{"product_id":"mitsubishi-lgh160rvxt3-e-250x750mm-spigot","title":"Mitsubishi LGH160RVXT3-E (250x750mm Spigot)","description":"\u003ch2\u003eMitsubishi LGH160RVXT3-E (250x750mm Spigot)\u003c\/h2\u003e\n\u003ch2\u003e\n\u003cstrong class=\"type\"\u003eOverview\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"value\"\u003e\n\u003cul\u003e\n\u003cli\u003ePower Supply: 3 Phase\u003c\/li\u003e\n\u003cli\u003eMitsubishi Electric pioneered heat exchanger enables maximised latent heat exchange, resulting in cost and carbon savings\u003c\/li\u003e\n\u003cli\u003eLow unit height (500mm) and lightweight structure, ideal for ceiling installation\u003c\/li\u003e\n\u003cli\u003eFour commissionable fan speeds, settable between 25-100%, with independent supply and return fan control offering low running costs and easier compliance to Part L\u003c\/li\u003e\n\u003cli\u003eOptional Mitsubishi Electric energy saving CO2 sensors allow automatic incremental fan control for a healthy indoor environment; sensors powered by Lossnay unit\u003c\/li\u003e\n\u003cli\u003eNo condensate drain required allowing for easy design and installation\u003c\/li\u003e\n\u003cli\u003eDual-barrier coated fans, prevents dust and grease accumulation, ensuring long-term efficient fan operation\u003c\/li\u003e\n\u003cli\u003eConstant pressure control available with 0-10V pressure transducer (field supplied), for variable airflow requirements across multiple zones\u003c\/li\u003e\n\u003cli\u003eCompatible with Mr Slim and City Multi air conditioning systems for a complete and highly effective system operation\u003c\/li\u003e\n\u003cli\u003eDuct handing selectable via dipswitch, for easy and flexible installation\u003c\/li\u003e\n\u003cli\u003eOptional high efficiency filters available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Part Number\u003c\/h3\u003e\n\u003cp\u003eLGH160RVXT3-E\u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Commercial Lossnay (LGH) Mechanical Ventilation Heat Recovery (MVHR) systems are designed to supply clean, fresh air into commercial buildings, whilst simultaneously extracting stale air. The RVXT3 units offer a significantly reduced height whilst maintaining a large airflow, allowing easy installation in ceiling voids.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Supply: 3 Phase\u003c\/li\u003e\n\u003cli\u003eMitsubishi Electric pioneered heat exchanger enables maximised latent heat exchange, resulting in cost and carbon savings\u003c\/li\u003e\n\u003cli\u003eLow unit height (500mm) and lightweight structure, ideal for ceiling installation\u003c\/li\u003e\n\u003cli\u003eFour commissionable fan speeds, settable between 25-100%, with independent supply and return fan control offering low running costs and easier compliance to Part L\u003c\/li\u003e\n\u003cli\u003eOptional Mitsubishi Electric energy saving CO2 sensors allow automatic incremental fan control for a healthy indoor environment; sensors powered by Lossnay unit\u003c\/li\u003e\n\u003cli\u003eNo condensate drain required allowing for easy design and installation\u003c\/li\u003e\n\u003cli\u003eDual-barrier coated fans, prevents dust and grease accumulation, ensuring long-term efficient fan operation\u003c\/li\u003e\n\u003cli\u003eConstant pressure control available with 0-10V pressure transducer (field supplied), for variable airflow requirements across multiple zones\u003c\/li\u003e\n\u003cli\u003eCompatible with Mr Slim and City Multi air conditioning systems for a complete and highly effective system operation\u003c\/li\u003e\n\u003cli\u003eDuct handing selectable via dipswitch, for easy and flexible installation\u003c\/li\u003e\n\u003cli\u003eOptional high efficiency filters available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/OFFICE_IMAGE_1.webp?v=1739292355\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/FLOW_RATES_RVXT3.webp?v=1739292355\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/RVXT3_DIMENSIONS.webp?v=1739292354\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":53736469365062,"sku":"LGH160RVXT3-E","price":4377.11,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/rvxt3-unit.jpg?v=1732556519"},{"product_id":"mitsubishi-lgh250rvxt3-e-250x750mm-spigot","title":"Mitsubishi LGH250RVXT3-E (250x750mm Spigot)","description":"\u003ch2\u003eMitsubishi LGH250RVXT3-E (250x750mm Spigot)\u003c\/h2\u003e\n\u003ch3\u003e\n\u003cstrong class=\"type\"\u003eOverview\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"value\"\u003e\n\u003cul\u003e\n\u003cli\u003ePower Supply: 3 Phase\u003c\/li\u003e\n\u003cli\u003eMitsubishi Electric pioneered heat exchanger enables maximised latent heat exchange, resulting in cost and carbon savings\u003c\/li\u003e\n\u003cli\u003eLow unit height (500mm) and lightweight structure, ideal for ceiling installation\u003c\/li\u003e\n\u003cli\u003eFour commissionable fan speeds, settable between 25-100%, with independent supply and return fan control offering low running costs and easier compliance to Part L\u003c\/li\u003e\n\u003cli\u003eOptional Mitsubishi Electric energy saving CO2 sensors allow automatic incremental fan control for a healthy indoor environment; sensors powered by Lossnay unit\u003c\/li\u003e\n\u003cli\u003eNo condensate drain required allowing for easy design and installation\u003c\/li\u003e\n\u003cli\u003eDual-barrier coated fans, prevents dust and grease accumulation, ensuring long-term efficient fan operation\u003c\/li\u003e\n\u003cli\u003eConstant pressure control available with 0-10V pressure transducer (field supplied), for variable airflow requirements across multiple zones\u003c\/li\u003e\n\u003cli\u003eCompatible with Mr Slim and City Multi air conditioning systems for a complete and highly effective system operation\u003c\/li\u003e\n\u003cli\u003eDuct handing selectable via dipswitch, for easy and flexible installation\u003c\/li\u003e\n\u003cli\u003eOptional high efficiency filters available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Part Number\u003c\/h3\u003e\n\u003cp\u003eLGH250RVXT3-E\u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Commercial Lossnay (LGH) Mechanical Ventilation Heat Recovery (MVHR) systems are designed to supply clean, fresh air into commercial buildings, whilst simultaneously extracting stale air. The RVXT3 units offer a significantly reduced height whilst maintaining a large airflow, allowing easy installation in ceiling voids.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Supply: 3 Phase\u003c\/li\u003e\n\u003cli\u003eMitsubishi Electric pioneered heat exchanger enables maximised latent heat exchange, resulting in cost and carbon savings\u003c\/li\u003e\n\u003cli\u003eLow unit height (500mm) and lightweight structure, ideal for ceiling installation\u003c\/li\u003e\n\u003cli\u003eFour commissionable fan speeds, settable between 25-100%, with independent supply and return fan control offering low running costs and easier compliance to Part L\u003c\/li\u003e\n\u003cli\u003eOptional Mitsubishi Electric energy saving CO2 sensors allow automatic incremental fan control for a healthy indoor environment; sensors powered by Lossnay unit\u003c\/li\u003e\n\u003cli\u003eNo condensate drain required allowing for easy design and installation\u003c\/li\u003e\n\u003cli\u003eDual-barrier coated fans, prevents dust and grease accumulation, ensuring long-term efficient fan operation\u003c\/li\u003e\n\u003cli\u003eConstant pressure control available with 0-10V pressure transducer (field supplied), for variable airflow requirements across multiple zones\u003c\/li\u003e\n\u003cli\u003eCompatible with Mr Slim and City Multi air conditioning systems for a complete and highly effective system operation\u003c\/li\u003e\n\u003cli\u003eDuct handing selectable via dipswitch, for easy and flexible installation\u003c\/li\u003e\n\u003cli\u003eOptional high efficiency filters available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/OFFICE_IMAGE_1.webp?v=1739292355\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/FLOW_RATES_RVXT3.webp?v=1739292355\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/RVXT3_DIMENSIONS.webp?v=1739292354\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":53736469397830,"sku":"LGH250RVXT3-E","price":6270.26,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/rvxt3-unit_1.jpg?v=1732556523"},{"product_id":"mitsubishi-lgh250rvxt3-e-250x750mm-spigot-1","title":"Mitsubishi LGH200RVXT3-E (250x750mm Spigot)","description":"\u003ch2\u003eMitsubishi LGH200RVXT3-E (250x750mm Spigot)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong class=\"type\"\u003eOverview\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"value\"\u003e\n\u003cul\u003e\n\u003cli\u003ePower Supply: 3 Phase\u003c\/li\u003e\n\u003cli\u003eMitsubishi Electric pioneered heat exchanger enables maximised latent heat exchange, resulting in cost and carbon savings\u003c\/li\u003e\n\u003cli\u003eLow unit height (500mm) and lightweight structure, ideal for ceiling installation\u003c\/li\u003e\n\u003cli\u003eFour commissionable fan speeds, settable between 25-100%, with independent supply and return fan control offering low running costs and easier compliance to Part L\u003c\/li\u003e\n\u003cli\u003eOptional Mitsubishi Electric energy saving CO2 sensors allow automatic incremental fan control for a healthy indoor environment; sensors powered by Lossnay unit\u003c\/li\u003e\n\u003cli\u003eNo condensate drain required allowing for easy design and installation\u003c\/li\u003e\n\u003cli\u003eDual-barrier coated fans, prevents dust and grease accumulation, ensuring long-term efficient fan operation\u003c\/li\u003e\n\u003cli\u003eConstant pressure control available with 0-10V pressure transducer (field supplied), for variable airflow requirements across multiple zones\u003c\/li\u003e\n\u003cli\u003eCompatible with Mr Slim and City Multi air conditioning systems for a complete and highly effective system operation\u003c\/li\u003e\n\u003cli\u003eDuct handing selectable via dipswitch, for easy and flexible installation\u003c\/li\u003e\n\u003cli\u003eOptional high efficiency filters available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Part Number\u003c\/h3\u003e\n\u003cp\u003eLGH200RVXT3-E\u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Commercial Lossnay (LGH) Mechanical Ventilation Heat Recovery (MVHR) systems are designed to supply clean, fresh air into commercial buildings, whilst simultaneously extracting stale air. The RVXT3 units offer a significantly reduced height whilst maintaining a large airflow, allowing easy installation in ceiling voids.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Supply: 3 Phase\u003c\/li\u003e\n\u003cli\u003eMitsubishi Electric pioneered heat exchanger enables maximised latent heat exchange, resulting in cost and carbon savings\u003c\/li\u003e\n\u003cli\u003eLow unit height (500mm) and lightweight structure, ideal for ceiling installation\u003c\/li\u003e\n\u003cli\u003eFour commissionable fan speeds, settable between 25-100%, with independent supply and return fan control offering low running costs and easier compliance to Part L\u003c\/li\u003e\n\u003cli\u003eOptional Mitsubishi Electric energy saving CO2 sensors allow automatic incremental fan control for a healthy indoor environment; sensors powered by Lossnay unit\u003c\/li\u003e\n\u003cli\u003eNo condensate drain required allowing for easy design and installation\u003c\/li\u003e\n\u003cli\u003eDual-barrier coated fans, prevents dust and grease accumulation, ensuring long-term efficient fan operation\u003c\/li\u003e\n\u003cli\u003eConstant pressure control available with 0-10V pressure transducer (field supplied), for variable airflow requirements across multiple zones\u003c\/li\u003e\n\u003cli\u003eCompatible with Mr Slim and City Multi air conditioning systems for a complete and highly effective system operation\u003c\/li\u003e\n\u003cli\u003eDuct handing selectable via dipswitch, for easy and flexible installation\u003c\/li\u003e\n\u003cli\u003eOptional high efficiency filters available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/OFFICE_IMAGE_1.webp?v=1739292355\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/FLOW_RATES_RVXT3.webp?v=1739292355\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/RVXT3_DIMENSIONS.webp?v=1739292354\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":53736469463366,"sku":"LGH200RVXT3-E","price":5245.74,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/rvxt3-unit_1_1.jpg?v=1732556527"},{"product_id":"mitsubishi-80lgh-rvs-e-with-pvc-core","title":"Mitsubishi LGH-80 RVS-E  With PVC core","description":"\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for commercial offices and schools \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePerfect for higher humidity environments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAirflow Rate of 800 m3\/hr \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e250 mm duct diameter \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSide and rear spigot options to external pipes \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUp to 90% heat Recovery rate \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe Mitsubishi LGH-80 RVS-E is a popular commercial heat recovery unit and is suitable for any type of commercial application including shower and changing rooms due to the latest PVC heat exchanger\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eKey features- Mitsubishi Lossnay LGH-80 RVS-E\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAirflow Rate of 800 m3\/hr \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e250 mm duct diameter \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSide and rear spigot options to external pipes \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUp to 90% heat Recovery rate \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLatest PVC core suitable for wet areas \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ecompliance with Part L\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional Mitsubishi Electric energy saving CO2 sensors \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e100% Summer By-Pass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLightweight structure ideal for easy ceiling installation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional digital Controller\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional F7 filtration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e0-10V input option.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eControllability\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eVolt Free contact\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePCB Dipswitch function\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional Controller\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional 12v signal \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional External sensors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional 0-10v DC Input \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional Wi-Fi Interface \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional M-Net connectivity \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eControl compatibility with Mr Slim and City Multi air conditioning systems for a complete and highly effective system operation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg height=\"330\" width=\"360\" src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXch7bFpln_0bySBZOiNXV0gBW54C200yVS3JmlLGivMXrdPDlr-wp-ZWiROhoPbZtWr3yLCZsRDV3U8V0reaSYRAkun18GokRpiD3bHYzqi-fUL3YLRg2mrTKbBrUH7MXpG7QzL-UTPZq4N4qqt02A?key=0rYPv0Oz5hRIgaRCRL9TUt9t\"\u003e\u003c\/span\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWall LCD controller (optional)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe optional wall controller PZ-62DR-EB\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003ewill allow you to\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAdjust Fan Speed in 5% increments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFilter warning \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWeekley Timer \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNighttime Purge\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSummer By-Pass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTemperature \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional Co2 display\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance and Run Time \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect to other Mitsubishi products \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperate Multiple Units (max 15)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg height=\"228\" width=\"624\" src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXf5iyDlr9O9SVSiKsxS01mTBEjtxjo5qllEymHVFptkWl6u6uzCjqHDpI8AoFx4cEFJ3N-Q3PHhJEV5VHzEOFegvFQvkx2RwC4K0plA6p5m8y6Rag-rA9jjRP2OEfBMdt08kxH7QFH9zxE6BRkhAY8?key=0rYPv0Oz5hRIgaRCRL9TUt9t\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eCo2 Sensors \u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWith the option of an additional CO2 sensor. When connected with the optional Wi-Fi Control Interface, CO2 levels can be viewed in real-time making it ideal for schools, medical facilities and offices.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIt is well known that poor air quality impacts health, wellbeing and concentration levels. In conjunction with the CO2 sensor, the Lossnay LGH-RVX3-E system intuitively adjusts airflow to ensure optimum air quality, no matter how many people are in the room.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTwo types of CO2 sensors are available: wall-mounted and duct-mounted types. Power is supplied to the CO2 sensor from the Lossnay board.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg height=\"345\" width=\"650\" src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXfnapGxUpfoStk5zDQqqUL5GNPDSLLRvoD4bEBviPLqG87UDt-SD1YsEpzV9CFxqvmYr_BLSB9e1e8-3q1shTilq77gu_4qrEcwZIHCLCUYnZWUuS0QrahqcizDszUDzMGPKzi2cnMmO7h-RAhhb7c?key=0rYPv0Oz5hRIgaRCRL9TUt9t\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe Mitsubishi LGH units’ range are manufactured of airtight and noise absorbing EPP with a metal outer cover\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg height=\"305\" width=\"624\" src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXdlX_VNyf25HLFi5mEkRmqFDtA4hJdTuEKgEME0eqpBkj7zlcceyywXPvIgPUX6kcDbxGjNfACC462lepIF2GKT93zj2ghqjKxtZlY02_vydUxbbfJtg4ddLScIeJbDSqLJkDN4c_eo9SoH1W1Gggw?key=0rYPv0Oz5hRIgaRCRL9TUt9t\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eMotors\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHigh quality commercial motors with Dual-Barrier coating on the fan prevents dust and grease accumulation, ensuring long-term efficient operation \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFlexible supply and exhaust fan commissioning in 5% increments, offering low running costs and easier\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe default fan speed value (Fan speed 1: 25%, Fan speed 2: 50%, Fan speed 3: 75%, and Fan speed 4: 100%) of both supply air and exhaust air can be adjusted flexibly. Within the range between 25% and 100%, airflow can be adjusted by 5% increments to satisfactorily meet the designed airflow rate.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eDual Barrier Coating\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDual Barrier Coating prevents dust and oil build-up on the interior of the Lossnay unit, helping to keep it clean for optimal performance. A water-repellent effect is achieved by creating a coating film that has nano-sized concave-convex structures formed by silica nanoparticles made of water-repellent fluor resin and micron-sized concave-convex structures formed by combining micronized special-shaped particles (silicate) with the silica nanoparticles. At the same time, the uneven structure forms an air layer that suppresses the adhesion of dust and sand that contain a lot of humidity, reducing the amount of dirt that adheres to the substrate.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eFiltration \u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e2 x G3 filters are fitted to the unit that are easy to replace \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional F7 to air supply\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eSummer By-Pass\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe units have a 100% summer by-Pass \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg height=\"220\" width=\"399\" src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXeVSHjx22XhLpbQ_4IwYXMENJWFrtY35571pOkScEOj3wzw4pngy1oulncXyWlAJ-tSmitMNhmNSnFTD76Y6WisfEKrFZ5_L4W1pEzdJl7d1C8kSt-DwVgzzI2YTKNhPVaEsfSrB4o_FyMfkddWw5U?key=0rYPv0Oz5hRIgaRCRL9TUt9t\" alt=\"A close-up of a black and silver air conditioner\n\nAI-generated content may be incorrect.\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eHeat Exchanger \u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe PVC heat exchange can recover up to 90% of normally wasted heat and can be used in areas of high humidity like showers and changing rooms \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eFrost Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe unit has a frost protection programme \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eOrientation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe unit is available in only one orientation \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe external pipes can be repositioned from the rear to side if required \u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eMounting \u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe units are supplied with ceiling mounting brackets and optional wall mounting brackets are available \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMitsubishi offer a 3-year warranty with this unit \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eAccessories \u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eRemote controller – PZ-62DR-EB\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStandard Filters – PZ-80RF3-E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eF7 Filter – PZ-80RFP3-E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWall Mounted Co2 Sensor – PZ-70CSW-E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDuct Mounted Co2 Sensor – PZ-70CSD-E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVertical Mounting Bracket – PZ-1VS-E\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eFurther Information\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFurther information is available on the Manufactures website \u003c\/span\u003e\u003ca href=\"https:\/\/les.mitsubishielectric.co.uk\/products\/ventilation\/commercial-ventilation-units\/commercial-lossnay-series\/rvx3\"\u003e\u003cspan\u003e(Click Here)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eTechnical Spec\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg height=\"247\" width=\"624\" src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXdsUrJbj6gtAcCU8M7GrlC1gSvrK-j8cvR-lqOiXqQWYwyQej-EKFSc5XtsiCzuYX_JyKuo5Zr7G1-_ycPxz4UpR3xcOPhBYUzDMZprOikYVimHcSSxM9DIIQegNaN-F1UWzoSGqnirN5Rei9ihbg?key=0rYPv0Oz5hRIgaRCRL9TUt9t\" alt=\"A screenshot of a computer\n\nAI-generated content may be incorrect.\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Data\u003c\/b\u003e\u003c\/h3\u003e\n\u003cdiv align=\"left\" dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"311\"\u003e \u003ccol width=\"101\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eLGH-80RVS-E\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHeat Recovery efficiency %\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e90\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAirflow rate @ 100-Pa m3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e800\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSFP (lowest)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e0.58\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDimensions W x H x D (mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e1185-997-465\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWeight Kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e63\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFiltration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e2XG3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePre\/ Post Heater\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ex\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSummer Bypass \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFrost protection \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSound level @3m db.(a)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e18-36\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCeiling \/ Floor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDuctwork Connection Location\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSide\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDuctwork Diameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e250\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCondensate drain\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e3 Years\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCountry of manufacture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHeat exchanger\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCounterflow\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDigital Controller\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOptional\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBoost Switch control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eInteractive App Control \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eInternal Humidity control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eInternal Co2 Sensor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eElectronic Orientation change\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAvailable room sensors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBMS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eKNX\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFireplace mode\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAlarm system integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOptional\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSAP Appendix Q\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePassive House Approved\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cb id=\"docs-internal-guid-2eeff581-7fff-fc88-d209-d520a83baa0a\"\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":54173937762630,"sku":"LGH-80RVS-E","price":2962.24,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lgh-50rvs-e.jpg?v=1732555693"},{"product_id":"mitsubishi-100lgh-rvs-e-with-pvc-core","title":"Mitsubishi LGH-100RVS-E  With PVC core","description":"\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for commercial offices and schools \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePerfect for higher humidity environments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAirflow Rate of 1000 m3\/hr \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e250 mm duct diameter \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSide and rear spigot options to external pipes \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUp to 90% heat Recovery rate \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eThe Mitsubishi LGH-100 RVS-E is a popular commercial heat recovery unit and is suitable for any type of commercial application including shower and changing rooms due to the latest PVC heat exchanger\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eKey features- Mitsubishi Lossnay LGH-100 RVS-E\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eAirflow Rate of 1000 m3\/hr \u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003e250 mm duct diameter \u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eSide and rear spigot options to external pipes \u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eUp to 90% heat Recovery rate \u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eLatest PVC core suitable for wet areas \u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003ecompliance with Part L\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eOptional Mitsubishi Electric energy saving CO2 sensors \u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003e100% Summer By-Pass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eLightweight structure ideal for easy ceiling installation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eOptional digital Controller\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eOptional F7 filtration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003e0-10V input option.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eControllability\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eVolt Free contact\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003ePCB Dipswitch function\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eOptional Controller\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eOptional 12v signal \u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eOptional External sensors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eOptional 0-10v DC Input \u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eOptional Wi-Fi Interface \u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eOptional M-Net connectivity \u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eControl compatibility with Mr Slim and City Multi air conditioning systems for a complete and highly effective system operation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXd_C6G3DG6bPQjci_Vx3xvadK2IrxLT4Hzi5uyvTZJtI6ue3sU4g4cGdkY53HGXdmAcADRTLUdeL0mBKkifNbvdkn-MzsRdgekhGAILEMYwcerE9PklrLVFl4kgwTgrKGW9ug8qPO0Wzn_dDUNhvFc?key=FaQMeZlvmEPIUkUQim4Z9Z5l\" width=\"360\" height=\"330\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWall LCD controller (optional)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe optional wall controller PZ-62DR-EB\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003ewill allow you to\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAdjust Fan Speed in 5% increments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFilter warning \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWeekley Timer \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNighttime Purge\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSummer By-Pass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTemperature \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional Co2 display\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance and Run Time \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect to other Mitsubishi products \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperate Multiple Units (max 15)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXcWZIPtNutEhl1nN1XdVKMaWuBnA3pfDcFdeYgllrxb9kZcdcyepwlTBDxleUDlNV8Lp1ZQpA7iXyROaPYSmX0ZRrRWadpx4WDgCFocuW2E-roIq_0dZVon9Wxojm8Wp0FpoYDBib2nE2lUbaSyCtU?key=FaQMeZlvmEPIUkUQim4Z9Z5l\" width=\"624\" height=\"228\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eCo2 Sensors \u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWith the option of an additional CO2 sensor. When connected with the optional Wi-Fi Control Interface, CO2 levels can be viewed in real-time making it ideal for schools, medical facilities and offices.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIt is well known that poor air quality impacts health, wellbeing and concentration levels. In conjunction with the CO2 sensor, the Lossnay LGH-RVX3-E system intuitively adjusts airflow to ensure optimum air quality, no matter how many people are in the room.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTwo types of CO2 sensors are available: wall-mounted and duct-mounted types. Power is supplied to the CO2 sensor from the Lossnay board.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXc4j0pOQQ5Rgk5JQR8aD2gBt6VmfpdFnNprryn11btIaEndgdTI3H_6FF0KfpkhCnlE_eET1OMlbxk2QPd3Rwt-5vHCMVESxbHp1Deg-YZFTLDq-1-caz3JnhrbTH-6baf6NA7PNk-ltfcQaDcaErA?key=FaQMeZlvmEPIUkUQim4Z9Z5l\" width=\"650\" height=\"345\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe Mitsubishi LGH units’ range are manufactured of airtight and noise absorbing EPP with a metal outer cover\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXfqqAd8bTGGrWan-7kmbVjQHUuEQmFMlk9U-3jQ5Hg1Ilun2_spRJFCiS3oTaPXyVrI2b40kRofS7JCNlJ2OV2M3CRH-S4j49ksN6ToBxnSYeacoYoSsnMU7Qfl7mpIPjNCtuYuj6TOmRsjYf1kOXU?key=FaQMeZlvmEPIUkUQim4Z9Z5l\" width=\"624\" height=\"305\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eMotors\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHigh quality commercial motors with Dual-Barrier coating on the fan prevents dust and grease accumulation, ensuring long-term efficient operation \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFlexible supply and exhaust fan commissioning in 5% increments, offering low running costs and easier\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe default fan speed value (Fan speed 1: 25%, Fan speed 2: 50%, Fan speed 3: 75%, and Fan speed 4: 100%) of both supply air and exhaust air can be adjusted flexibly. Within the range between 25% and 100%, airflow can be adjusted by 5% increments to satisfactorily meet the designed airflow rate.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eDual Barrier Coating\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDual Barrier Coating prevents dust and oil build-up on the interior of the Lossnay unit, helping to keep it clean for optimal performance. A water-repellent effect is achieved by creating a coating film that has nano-sized concave-convex structures formed by silica nanoparticles made of water-repellent fluor resin and micron-sized concave-convex structures formed by combining micronized special-shaped particles (silicate) with the silica nanoparticles. At the same time, the uneven structure forms an air layer that suppresses the adhesion of dust and sand that contain a lot of humidity, reducing the amount of dirt that adheres to the substrate.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eFiltration \u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003e2 x G3 filters are fitted to the unit that are easy to replace \u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eOptional F7 to air supply\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eSummer By-Pass\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe units have a 100% summer by-Pass \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg alt=\"A close-up of a black and silver air conditioner\n\nAI-generated content may be incorrect.\" src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXe-udGo9KzKe1qTc0ADe1Rx_iTrHnZEGty6s30rgH9Q_abmZQqvbDzQGJ2qNU0dDiaRhuhrwqF4r7yYLvva-W-iDHyI-DB3wzc4tmRy9g5kTUHJeqJndrGpH_boTPF1y92Ax1HgE7wY2CJ18vjP7Q?key=FaQMeZlvmEPIUkUQim4Z9Z5l\" width=\"399\" height=\"220\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eHeat Exchanger \u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe PVC heat exchange can recover up to 90% of normally wasted heat and can be used in areas of high humidity like showers and changing rooms \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eFrost Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe unit has a frost protection programme \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eOrientation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe unit is available in only one orientation \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe external pipes can be repositioned from the rear to side if required \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eMounting \u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe units are supplied with ceiling mounting brackets and optional wall mounting brackets are available \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMitsubishi offer a 3-year warranty with this unit \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eAccessories \u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eRemote controller – PZ-62DR-EB\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eStandard Filters – PZ-100RF3-E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eF7 Filter – PZ-100RFP3-E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eWall Mounted Co2 Sensor – PZ-70CSW-E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eDuct Mounted Co2 Sensor – PZ-70CSD-E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eVertical Mounting Bracket – PZ-1VS-E\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eFurther Information\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFurther information is available on the Manufactures website \u003c\/span\u003e\u003ca href=\"https:\/\/les.mitsubishielectric.co.uk\/products\/ventilation\/commercial-ventilation-units\/commercial-lossnay-series\/rvx3\"\u003e\u003cspan\u003e(Click Here)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical \u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cimg alt=\"A screenshot of a computer\n\nAI-generated content may be incorrect.\" src=\"https:\/\/lh7-rt.googleusercontent.com\/docsz\/AD_4nXctUhktmS1A2tjuactAlpxGU0ddxCzOyNgCTCRJqPsFuxOZ1YH88zyFttQrtSOspsVHkyR5HVliWR6Z_Zf7EATjSCo-YHoRCspQo9Pph8iJMhZcvzmHtezniWr6Vkn2q3jrx9a6sNutK0fctuwif8U?key=FaQMeZlvmEPIUkUQim4Z9Z5l\" width=\"624\" height=\"247\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv dir=\"ltr\" align=\"left\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"311\"\u003e \u003ccol width=\"101\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eLGH-100RVS-E\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHeat Recovery efficiency %\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e90\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAirflow rate @ 100-Pa m3\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSFP (lowest)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e0.5\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDimensions W x H x D (mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e1185-997-465\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWeight Kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e73\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFiltration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e2XG3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePre\/ Post Heater\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ex\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSummer Bypass \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFrost protection \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSound level @3m db.(a)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e18-37\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCeiling \/ Floor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDuctwork Connection Location\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSide\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDuctwork Diameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e250\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCondensate drain\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e3 Years\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCountry of manufacture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHeat exchanger\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCounterflow\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDigital Controller\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOptional\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBoost Switch control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eInteractive App Control \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eInternal Humidity control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eInternal Co2 Sensor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eElectronic Orientation change\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAvailable room sensors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBMS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eKNX\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFireplace mode\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAlarm system integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOptional\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSAP Appendix Q\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePassive House Approved\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":54173938188614,"sku":"LGH-100RVS-E","price":3410.02,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/lgh-50rvs-e.jpg?v=1732555693"}],"url":"https:\/\/bpcventilation.com\/collections\/commercial-mvhr-units.oembed?page=2","provider":"BPC Ventilation Store","version":"1.0","type":"link"}